Characterizing the voxel‐based approaches in radioembolization dosimetry with reDoseMC
Fuente:
Wiley Open Access
Saved in:
| Main Authors: | Taehyung Peter Kim, Shirin A. Enger |
|---|---|
| Format: | Artículo Open Access |
| Published: |
Wiley
2024
|
| Subjects: | |
| Online Access: | |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Similar Items
Enhancing voxel‐based dosimetry accuracy with an unsupervised deep learning approach for hybrid medical image registration
by: Keon Min Kim, et al.
Published: (2024)
by: Keon Min Kim, et al.
Published: (2024)
E‐Brachy: New dosimetry package for electronic brachytherapy sources
by: Azin Esmaelbeigi, et al.
Published: (2024)
by: Azin Esmaelbeigi, et al.
Published: (2024)
Quantitative evaluation of 90Y‐PET/CT and 90Y‐SPECT/CT‐based dosimetry following Yttrium‐90 radioembolization
by: Srinivas Cheenu Kappadath, et al.
Published: (2024)
by: Srinivas Cheenu Kappadath, et al.
Published: (2024)
Dosimetric impact of positional uncertainties and a robust optimization approach for rectal intensity‐modulated brachytherapy
by: Björn Morén, et al.
Published: (2025)
by: Björn Morén, et al.
Published: (2025)
Linear Boltzmann equation solver for voxel‐level dosimetry in radiopharmaceutical therapy: Comparison with Monte Carlo and kernel convolution
by: Gunjan Kayal, et al.
Published: (2024)
by: Gunjan Kayal, et al.
Published: (2024)
Dosimetric impact of clinical planning methodology for Yttrium‐90 microsphere radioembolization
by: Terrance Moretti, et al.
Published: (2026)
by: Terrance Moretti, et al.
Published: (2026)
Clinical test cases for commissioning, QA, and benchmarking of model‐based dose calculation algorithms in 1 ⁹ 2 Ir HDR gynecologic tandem and ring brachytherapy
by: Vasiliki Peppa, et al.
Published: (2026)
by: Vasiliki Peppa, et al.
Published: (2026)
Trade‐off of different deep learning‐based auto‐segmentation approaches for treatment planning of pediatric craniospinal irradiation autocontouring of OARs for pediatric CSI
by: Alana Thibodeau‐Antonacci, et al.
Published: (2025)
by: Alana Thibodeau‐Antonacci, et al.
Published: (2025)
Development and characterization of a prototype selenium‐75 high dose rate brachytherapy source
by: Jonathan Kalinowski, et al.
Published: (2025)
by: Jonathan Kalinowski, et al.
Published: (2025)
A comparison of methods for in vivo activity and absorbed dose quantification with PET/CT following yttrium‐90 radioembolization
by: Eric Courtney Henry, et al.
Published: (2024)
by: Eric Courtney Henry, et al.
Published: (2024)
Investigation of inter‐source and intra‐source spectral variations in an electronic brachytherapy source using spectral measurements and Monte Carlo simulations
by: Azin Esmaelbeigi, et al.
Published: (2026)
by: Azin Esmaelbeigi, et al.
Published: (2026)
Characterization of a novel plastic scintillation detector for in vivo electron dosimetry
by: Bauer, Cornelius J., et al.
Published: (2025)
by: Bauer, Cornelius J., et al.
Published: (2025)
Investigation of dosimetric characteristics of radiochromic film in response to alpha particles emitted from Americium‐241
by: Victor D. Diaz‐Martinez, et al.
Published: (2024)
by: Victor D. Diaz‐Martinez, et al.
Published: (2024)
Simplified image‐based dosimetry using planar images and patient‐specific S‐values
by: Keon Min Kim, et al.
Published: (2024)
by: Keon Min Kim, et al.
Published: (2024)
Microdosimetry calculations in situ for clinically relevant photon sources and their correlation with the early DNA damage response
by: Mirta Dumančić, et al.
Published: (2025)
by: Mirta Dumančić, et al.
Published: (2025)
Characterization of a commercial plastic scintillator for electron FLASH dosimetry
by: Kyuhak Oh, et al.
Published: (2024)
by: Kyuhak Oh, et al.
Published: (2024)
Characterization of commercial detectors for absolute proton UHDR dosimetry on a compact clinical proton synchrocyclotron
by: Jufri Setianegara, et al.
Published: (2025)
by: Jufri Setianegara, et al.
Published: (2025)
Feasibility study of surface deformation‐based dosimetry for breast cancer radiotherapy
by: Yongjin Deng, et al.
Published: (2026)
by: Yongjin Deng, et al.
Published: (2026)
Secondary neutron dosimetry for conformal FLASH proton therapy
by: Dixin Chen, et al.
Published: (2024)
by: Dixin Chen, et al.
Published: (2024)
Plaque‐adaptive flexible film dosimetry system for Ru‐106 plaque brachytherapy commissioning and quality assurance
by: Jin Dong Cho, et al.
Published: (2026)
by: Jin Dong Cho, et al.
Published: (2026)
Characterization of a novel plastic scintillation detector for in vivo electron dosimetry
by: Cornelius J. Bauer, et al.
Published: (2026)
by: Cornelius J. Bauer, et al.
Published: (2026)
Healthy lung and heart reference volumes and dosimetry phantoms from automatic CT segmentation
by: Chung Yoh Kim, et al.
Published: (2025)
by: Chung Yoh Kim, et al.
Published: (2025)
Nanoscale dosimetry for a radioisotope‐labeled metal nanoparticle using MCNP6.2 and Geant4
by: Taeyun Kim, et al.
Published: (2024)
by: Taeyun Kim, et al.
Published: (2024)
A device for production of PAGAT dosimetry gel
by: Christina Stengl, et al.
Published: (2025)
by: Christina Stengl, et al.
Published: (2025)
The self‐supervised fitting method based on similar neighborhood information of voxels for intravoxel incoherent motion diffusion‐weighted MRI
by: Lingfeng Luo, et al.
Published: (2025)
by: Lingfeng Luo, et al.
Published: (2025)
Technical note: Characterization of a multi‐point scintillation dosimetry research platform for a low‐field MR‐Linac
by: Jennie Crosby, et al.
Published: (2024)
by: Jennie Crosby, et al.
Published: (2024)
A feasibility study of dosimetry for breast cancer radiotherapy based on body surface changes
by: Yongjin Deng, et al.
Published: (2024)
by: Yongjin Deng, et al.
Published: (2024)
What if each voxel were measured with a different diffusion protocol?
by: Coelho, Santiago, et al.
Published: (2025)
by: Coelho, Santiago, et al.
Published: (2025)
Report on the quantitative intra‐voxel incoherent motion diffusion MRI reconstruction grand challenge
by: Xiaoyu Hu, et al.
Published: (2025)
by: Xiaoyu Hu, et al.
Published: (2025)
Synchrotron radiation-based tomography of an entire mouse brain with sub-micron voxels: augmenting interactive brain atlases with terabyte data
by: Humbel, Mattia, et al.
Published: (2024)
by: Humbel, Mattia, et al.
Published: (2024)
Applying voxel‐based analysis to oropharyngeal cancer proton therapy patients: A correlation study on radiation‐induced acute dysphagia
by: Qianxia Wang, et al.
Published: (2025)
by: Qianxia Wang, et al.
Published: (2025)
Seeing the invisible: In vivo dosimetry in radiotherapy with radiacoustic imaging
by: Kristina Bjegovic, et al.
Published: (2025)
by: Kristina Bjegovic, et al.
Published: (2025)
A GPU-based Monte Carlo framework for IMRT QA using EPID transit dosimetry
by: Gao, Ning, et al.
Published: (2025)
by: Gao, Ning, et al.
Published: (2025)
Clinical test cases for commissioning, QA, and benchmarking of model-based dose calculation algorithms in 192Ir HDR gynecologic tandem and ring brachytherapy
by: Peppa, V., et al.
Published: (2025)
by: Peppa, V., et al.
Published: (2025)
Characterization of a novel time-resolved, real-time scintillation dosimetry system for ultra-high dose rate radiation therapy applications
by: Baikalov, Alexander, et al.
Published: (2024)
by: Baikalov, Alexander, et al.
Published: (2024)
Characterizing the Radiation Dose to Measurement Accuracy Relationship across Multiple Metrics in Opportunistic Chest CT
by: Li, Boyuan, et al.
Published: (2026)
by: Li, Boyuan, et al.
Published: (2026)
Wide area surface dosimetry with conformal scintillator array for external beam radiotherapy
by: Roman Vasyltsiv, et al.
Published: (2026)
by: Roman Vasyltsiv, et al.
Published: (2026)
Harmonized connectome resampling for variance in voxel sizes
by: McMaster, Elyssa M., et al.
Published: (2024)
by: McMaster, Elyssa M., et al.
Published: (2024)
Minimum phantom size for megavoltage photon beam reference dosimetry
by: D. W. O. Rogers
Published: (2024)
by: D. W. O. Rogers
Published: (2024)
Conceptualization of electronic dose to water for dosimetry in external beam radiotherapy
by: Kanematsu, Nobuyuki
Published: (2024)
by: Kanematsu, Nobuyuki
Published: (2024)
Similar Items
-
Enhancing voxel‐based dosimetry accuracy with an unsupervised deep learning approach for hybrid medical image registration
by: Keon Min Kim, et al.
Published: (2024) -
E‐Brachy: New dosimetry package for electronic brachytherapy sources
by: Azin Esmaelbeigi, et al.
Published: (2024) -
Quantitative evaluation of 90Y‐PET/CT and 90Y‐SPECT/CT‐based dosimetry following Yttrium‐90 radioembolization
by: Srinivas Cheenu Kappadath, et al.
Published: (2024) -
Dosimetric impact of positional uncertainties and a robust optimization approach for rectal intensity‐modulated brachytherapy
by: Björn Morén, et al.
Published: (2025) -
Linear Boltzmann equation solver for voxel‐level dosimetry in radiopharmaceutical therapy: Comparison with Monte Carlo and kernel convolution
by: Gunjan Kayal, et al.
Published: (2024)