Protocol optimization for functional cardiac CT imaging using noise emulation in the raw data domain

Fuente: Wiley Open Access
Salvato in:
Dettagli Bibliografici
Autori principali: Zhye Yin, Pengwei Wu, Ashish Manohar, Elliot R. McVeigh, Jed D. Pack
Natura: Artículo Open Access
Pubblicazione: Wiley 2024
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1867002043723415552
author Zhye Yin
Pengwei Wu
Ashish Manohar
Elliot R. McVeigh
Jed D. Pack
author_facet Zhye Yin
Pengwei Wu
Ashish Manohar
Elliot R. McVeigh
Jed D. Pack
Zhye Yin
Pengwei Wu
Ashish Manohar
Elliot R. McVeigh
Jed D. Pack
collection Wiley Open Access
contents Protocol optimization for functional cardiac CT imaging using noise emulation in the raw data domain Zhye Yin Pengwei Wu Ashish Manohar Elliot R. McVeigh Jed D. Pack Medical Physics AbstractBackgroundFour‐dimensional (4D) wide coverage computed tomography (CT) is an effective imaging modality for measuring the mechanical function of the myocardium. However, repeated CT measurement across a number of heartbeats is still a concern.PurposeA projection‐domain noise emulation method is presented to generate accurate low‐dose (mA modulated) 4D cardiac CT scans from high‐dose scans, enabling protocol optimization to deliver sufficient image quality for functional cardiac analysis while using a dose level that is as low as reasonably achievable (ALARA).MethodsGiven a targeted low‐dose mA modulation curve, the proposed noise emulation method injects both quantum and electronic noise of proper magnitude and correlation to the high‐dose data in projection domain. A spatially varying (i.e., channel‐dependent) detector gain term as well as its calibration method were proposed to further improve the noise emulation accuracy. To determine the ALARA dose threshold, a straightforward projection domain image quality (IQ) metric was proposed that is based on the number of projection rays that do not fall under the non‐linear region of the detector response. Experiments were performed to validate the noise emulation method with both phantom and clinical data in terms of visual similarity, contrast‐to‐noise ratio (CNR), and noise‐power spectrum (NPS).ResultsFor both phantom and clinical data, the low‐dose emulated images exhibited similar noise magnitude (CNR difference within 2%), artifacts, and texture to that of the real low‐dose images. The proposed channel‐dependent detector gain term resulted in additional increase in emulation accuracy. Using the proposed IQ metric, recommended kVp and mA settings were calculated for low dose 4D Cardiac CT acquisitions for patients of different sizes.ConclusionsA detailed method to estimate system‐dependent parameters for a raw‐data based low dose emulation framework was described. The method produced realistic noise levels, artifacts, and texture with phantom and clinical studies. The proposed low‐dose emulation method can be used to prospectively select patient‐specific minimal‐dose protocols for functional cardiac CT. 10.1002/mp.17088 http://onlinelibrary.wiley.com/termsAndConditions#vor
doi_str_mv 10.1002/mp.17088
format Artículo Open Access
id wiley_oa_10_1002_mp_17088
institution Wiley Open Access
license_str_mv http://onlinelibrary.wiley.com/termsAndConditions#vor
publishDate 2024
publisher Wiley
record_format wiley_oa
spellingShingle Protocol optimization for functional cardiac CT imaging using noise emulation in the raw data domain
Zhye Yin
Pengwei Wu
Ashish Manohar
Elliot R. McVeigh
Jed D. Pack
Medical Physics
Protocol optimization for functional cardiac CT imaging using noise emulation in the raw data domain Zhye Yin Pengwei Wu Ashish Manohar Elliot R. McVeigh Jed D. Pack Medical Physics AbstractBackgroundFour‐dimensional (4D) wide coverage computed tomography (CT) is an effective imaging modality for measuring the mechanical function of the myocardium. However, repeated CT measurement across a number of heartbeats is still a concern.PurposeA projection‐domain noise emulation method is presented to generate accurate low‐dose (mA modulated) 4D cardiac CT scans from high‐dose scans, enabling protocol optimization to deliver sufficient image quality for functional cardiac analysis while using a dose level that is as low as reasonably achievable (ALARA).MethodsGiven a targeted low‐dose mA modulation curve, the proposed noise emulation method injects both quantum and electronic noise of proper magnitude and correlation to the high‐dose data in projection domain. A spatially varying (i.e., channel‐dependent) detector gain term as well as its calibration method were proposed to further improve the noise emulation accuracy. To determine the ALARA dose threshold, a straightforward projection domain image quality (IQ) metric was proposed that is based on the number of projection rays that do not fall under the non‐linear region of the detector response. Experiments were performed to validate the noise emulation method with both phantom and clinical data in terms of visual similarity, contrast‐to‐noise ratio (CNR), and noise‐power spectrum (NPS).ResultsFor both phantom and clinical data, the low‐dose emulated images exhibited similar noise magnitude (CNR difference within 2%), artifacts, and texture to that of the real low‐dose images. The proposed channel‐dependent detector gain term resulted in additional increase in emulation accuracy. Using the proposed IQ metric, recommended kVp and mA settings were calculated for low dose 4D Cardiac CT acquisitions for patients of different sizes.ConclusionsA detailed method to estimate system‐dependent parameters for a raw‐data based low dose emulation framework was described. The method produced realistic noise levels, artifacts, and texture with phantom and clinical studies. The proposed low‐dose emulation method can be used to prospectively select patient‐specific minimal‐dose protocols for functional cardiac CT. 10.1002/mp.17088 http://onlinelibrary.wiley.com/termsAndConditions#vor
title Protocol optimization for functional cardiac CT imaging using noise emulation in the raw data domain
topic Medical Physics
url https://aapm.onlinelibrary.wiley.com/doi/10.1002/mp.17088