Institutional experience with implanted cardiac device risk level assessment: Comparing calculation and measurement

Fuente: Wiley Open Access
Saved in:
Bibliographic Details
Main Authors: Stephen J. Gardner, Kyle Verdecchia, Brett M. Miller, Chadd E. Smith, Anthony Doemer, Aharon Feldman, Farzan Siddiqui, Benjamin Movsas, Kundan Thind
Format: Artículo Open Access
Published: Wiley 2025
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1867019424487178240
author Stephen J. Gardner
Kyle Verdecchia
Brett M. Miller
Chadd E. Smith
Anthony Doemer
Aharon Feldman
Farzan Siddiqui
Benjamin Movsas
Kundan Thind
author_facet Stephen J. Gardner
Kyle Verdecchia
Brett M. Miller
Chadd E. Smith
Anthony Doemer
Aharon Feldman
Farzan Siddiqui
Benjamin Movsas
Kundan Thind
Stephen J. Gardner
Kyle Verdecchia
Brett M. Miller
Chadd E. Smith
Anthony Doemer
Aharon Feldman
Farzan Siddiqui
Benjamin Movsas
Kundan Thind
collection Wiley Open Access
contents Institutional experience with implanted cardiac device risk level assessment: Comparing calculation and measurement Stephen J. Gardner Kyle Verdecchia Brett M. Miller Chadd E. Smith Anthony Doemer Aharon Feldman Farzan Siddiqui Benjamin Movsas Kundan Thind Medical Physics Abstract Background The use of in‐vivo dosimetry is a long‐standing but also labor‐intensive component of risk‐level assessment for patients with implanted devices. A calculation‐only approach, using treatment planning system (TPS)‐calculated doses along with imaging doses estimates when relevant, has the potential to streamline the physics workflow without negatively impacting patient safety. Purpose To evaluate the feasibility of using a calculation‐only approach for risk level assessment for patients with implanted electronic medical devices. Methods A total of 86 patients were included in this retrospective study. For each patient, in‐vivo dosimetry measurements using optically stimulated luminescent dosimeter (OSLD) were compared to calculated doses (based on TPS calculated doses and an estimate of imaging doses when relevant). The comparison of OSLD doses and estimated predicted doses was structured in the following manner: (1) direct comparison of both absolute dose difference and percent difference for measured and calculated doses, (2) risk level assessment comparison using measured and estimated doses, and (3) sensitivity and positive predictive value assessment of each method for TG‐203 risk level assessment. Results For all cases, the calculation‐based approach yielded a risk level that was equivalent to or more conservative than the risk level from OSLD measurement. For 79 of 86 patients (91.9%), the calculated and measured doses provided the same risk level. For 7 of 86 patients (8.1%), the calculated dose yielded the more conservative risk level. The calculation‐based dose estimate provided a sensitivity of 1.00 with a positive predictive value of 0.92. Conclusions The use of a calculation‐only approach has the potential to reduce workload while maintaining the efficacy of risk‐level assessment for patients with implanted devices. 10.1002/mp.17621 http://onlinelibrary.wiley.com/termsAndConditions#vor
doi_str_mv 10.1002/mp.17621
format Artículo Open Access
id wiley_oa_10_1002_mp_17621
institution Wiley Open Access
license_str_mv http://onlinelibrary.wiley.com/termsAndConditions#vor
publishDate 2025
publisher Wiley
record_format wiley_oa
spellingShingle Institutional experience with implanted cardiac device risk level assessment: Comparing calculation and measurement
Stephen J. Gardner
Kyle Verdecchia
Brett M. Miller
Chadd E. Smith
Anthony Doemer
Aharon Feldman
Farzan Siddiqui
Benjamin Movsas
Kundan Thind
Medical Physics
Institutional experience with implanted cardiac device risk level assessment: Comparing calculation and measurement Stephen J. Gardner Kyle Verdecchia Brett M. Miller Chadd E. Smith Anthony Doemer Aharon Feldman Farzan Siddiqui Benjamin Movsas Kundan Thind Medical Physics Abstract Background The use of in‐vivo dosimetry is a long‐standing but also labor‐intensive component of risk‐level assessment for patients with implanted devices. A calculation‐only approach, using treatment planning system (TPS)‐calculated doses along with imaging doses estimates when relevant, has the potential to streamline the physics workflow without negatively impacting patient safety. Purpose To evaluate the feasibility of using a calculation‐only approach for risk level assessment for patients with implanted electronic medical devices. Methods A total of 86 patients were included in this retrospective study. For each patient, in‐vivo dosimetry measurements using optically stimulated luminescent dosimeter (OSLD) were compared to calculated doses (based on TPS calculated doses and an estimate of imaging doses when relevant). The comparison of OSLD doses and estimated predicted doses was structured in the following manner: (1) direct comparison of both absolute dose difference and percent difference for measured and calculated doses, (2) risk level assessment comparison using measured and estimated doses, and (3) sensitivity and positive predictive value assessment of each method for TG‐203 risk level assessment. Results For all cases, the calculation‐based approach yielded a risk level that was equivalent to or more conservative than the risk level from OSLD measurement. For 79 of 86 patients (91.9%), the calculated and measured doses provided the same risk level. For 7 of 86 patients (8.1%), the calculated dose yielded the more conservative risk level. The calculation‐based dose estimate provided a sensitivity of 1.00 with a positive predictive value of 0.92. Conclusions The use of a calculation‐only approach has the potential to reduce workload while maintaining the efficacy of risk‐level assessment for patients with implanted devices. 10.1002/mp.17621 http://onlinelibrary.wiley.com/termsAndConditions#vor
title Institutional experience with implanted cardiac device risk level assessment: Comparing calculation and measurement
topic Medical Physics
url https://aapm.onlinelibrary.wiley.com/doi/10.1002/mp.17621