A multi‐modal diffusion model for noise reduction of particle number limited Monte Carlo dose calculation for carbon ion radiotherapy

Fuente: Wiley Open Access
Saved in:
Bibliographic Details
Main Authors: Jueye Zhang, Youfang Lai, Haonan Feng, Xiangde Luo, Kai‐Wen Li, Tenghui Wang, Cheng Chang, Gen Yang, Chen Lin, Tian Li, Chao Yang, Yibao Zhang
Format: Artículo Open Access
Published: Wiley 2025
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1867004032024838144
author Jueye Zhang
Youfang Lai
Haonan Feng
Xiangde Luo
Kai‐Wen Li
Tenghui Wang
Cheng Chang
Gen Yang
Chen Lin
Tian Li
Chao Yang
Yibao Zhang
author_facet Jueye Zhang
Youfang Lai
Haonan Feng
Xiangde Luo
Kai‐Wen Li
Tenghui Wang
Cheng Chang
Gen Yang
Chen Lin
Tian Li
Chao Yang
Yibao Zhang
Jueye Zhang
Youfang Lai
Haonan Feng
Xiangde Luo
Kai‐Wen Li
Tenghui Wang
Cheng Chang
Gen Yang
Chen Lin
Tian Li
Chao Yang
Yibao Zhang
collection Wiley Open Access
contents A multi‐modal diffusion model for noise reduction of particle number limited Monte Carlo dose calculation for carbon ion radiotherapy Jueye Zhang Youfang Lai Haonan Feng Xiangde Luo Kai‐Wen Li Tenghui Wang Cheng Chang Gen Yang Chen Lin Tian Li Chao Yang Yibao Zhang Medical Physics Abstract Background The low computation efficiency impeded the broad application of Monte Carlo (MC) simulation to particle therapy. The existing deep learning (DL) methods for fast dose calculation lacked physics‐based interpretability, hence, may introduce additional risks, especially for the more complex carbon ion radiotherapy. Purpose To develop and validate a multi‐modal diffusion model, Diff‐MC, for noise reduction of particle number limited MC dose calculation, potentially supporting better optimization and faster online adaptation for carbon ion radiotherapy. Methods By using multi‐modal data such as CT images, dose maps using a low number of primary particles and beam parameters, and so forth, Diff‐MC was developed to generate a dose map adaptively based on the beam state. To enable effective inter‐modal interactions, a hybrid‐fusion strategy was applied to integrate the data‐level, feature‐level, and decision‐level fusion. The model was evaluated on a highly heterogeneous dataset, including 15 000 paired beamlet data cropped from 20 CTs for training and validating, 500 paired beamlet data cropped from other 5 CTs for testing, and 500 paired beamlet data cropped from another 100 CTs for generalizability test. All datasets encompassed various geometry and beamlet physics parameters such as energy distribution and number of primary particles, and so forth. Results Using the MC simulation based on high number of primary particles as ground‐truth, the Diff‐MC achieved nearly linear acceleration and high accuracy of gamma passing rate up to 99.25% under the criteria of 3 mm, 3%, 10% cutoff. The performance was significantly higher (all ) than the UNet‐based models (96.17%) and transformer‐based models (97.81%). The accuracy achieved by Diff‐MC in the generalizability test was 99.22%. The lateral dose, integral depth dose (IDD), and percentage depth dose (PDD) of Diff‐MC were also more consistent with the ground‐truth than that of conventional AI models. Conclusions The proposed Diff‐MC method displayed high efficiency and robustness in carbon ion dose calculation. By maintaining the physics features of MC, the results of Diff‐MC were more interpretable and generalizable than the conventional AI models. 10.1002/mp.70021 http://onlinelibrary.wiley.com/termsAndConditions#vor
doi_str_mv 10.1002/mp.70021
format Artículo Open Access
id wiley_oa_10_1002_mp_70021
institution Wiley Open Access
license_str_mv http://onlinelibrary.wiley.com/termsAndConditions#vor
publishDate 2025
publisher Wiley
record_format wiley_oa
spellingShingle A multi‐modal diffusion model for noise reduction of particle number limited Monte Carlo dose calculation for carbon ion radiotherapy
Jueye Zhang
Youfang Lai
Haonan Feng
Xiangde Luo
Kai‐Wen Li
Tenghui Wang
Cheng Chang
Gen Yang
Chen Lin
Tian Li
Chao Yang
Yibao Zhang
Medical Physics
A multi‐modal diffusion model for noise reduction of particle number limited Monte Carlo dose calculation for carbon ion radiotherapy Jueye Zhang Youfang Lai Haonan Feng Xiangde Luo Kai‐Wen Li Tenghui Wang Cheng Chang Gen Yang Chen Lin Tian Li Chao Yang Yibao Zhang Medical Physics Abstract Background The low computation efficiency impeded the broad application of Monte Carlo (MC) simulation to particle therapy. The existing deep learning (DL) methods for fast dose calculation lacked physics‐based interpretability, hence, may introduce additional risks, especially for the more complex carbon ion radiotherapy. Purpose To develop and validate a multi‐modal diffusion model, Diff‐MC, for noise reduction of particle number limited MC dose calculation, potentially supporting better optimization and faster online adaptation for carbon ion radiotherapy. Methods By using multi‐modal data such as CT images, dose maps using a low number of primary particles and beam parameters, and so forth, Diff‐MC was developed to generate a dose map adaptively based on the beam state. To enable effective inter‐modal interactions, a hybrid‐fusion strategy was applied to integrate the data‐level, feature‐level, and decision‐level fusion. The model was evaluated on a highly heterogeneous dataset, including 15 000 paired beamlet data cropped from 20 CTs for training and validating, 500 paired beamlet data cropped from other 5 CTs for testing, and 500 paired beamlet data cropped from another 100 CTs for generalizability test. All datasets encompassed various geometry and beamlet physics parameters such as energy distribution and number of primary particles, and so forth. Results Using the MC simulation based on high number of primary particles as ground‐truth, the Diff‐MC achieved nearly linear acceleration and high accuracy of gamma passing rate up to 99.25% under the criteria of 3 mm, 3%, 10% cutoff. The performance was significantly higher (all ) than the UNet‐based models (96.17%) and transformer‐based models (97.81%). The accuracy achieved by Diff‐MC in the generalizability test was 99.22%. The lateral dose, integral depth dose (IDD), and percentage depth dose (PDD) of Diff‐MC were also more consistent with the ground‐truth than that of conventional AI models. Conclusions The proposed Diff‐MC method displayed high efficiency and robustness in carbon ion dose calculation. By maintaining the physics features of MC, the results of Diff‐MC were more interpretable and generalizable than the conventional AI models. 10.1002/mp.70021 http://onlinelibrary.wiley.com/termsAndConditions#vor
title A multi‐modal diffusion model for noise reduction of particle number limited Monte Carlo dose calculation for carbon ion radiotherapy
topic Medical Physics
url https://aapm.onlinelibrary.wiley.com/doi/10.1002/mp.70021