Development of a proof‐of‐concept treatment planning system for multi‐beam photon FLASH intensity modulated radiation therapy

Fuente: Wiley Open Access
Saved in:
Bibliographic Details
Main Authors: Guo Chenlei, Cui Weijie, Zha Hao, Zhu Meng, Ye Jin, Wang He, Wang Weiping, Zhu Hongyu, Zhou Yin, Dai Jianrong, Men Kuo
Format: Artículo Open Access
Published: Wiley 2026
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1867003249106616320
author Guo Chenlei
Cui Weijie
Zha Hao
Zhu Meng
Ye Jin
Wang He
Wang Weiping
Zhu Hongyu
Zhou Yin
Dai Jianrong
Men Kuo
author_facet Guo Chenlei
Cui Weijie
Zha Hao
Zhu Meng
Ye Jin
Wang He
Wang Weiping
Zhu Hongyu
Zhou Yin
Dai Jianrong
Men Kuo
Guo Chenlei
Cui Weijie
Zha Hao
Zhu Meng
Ye Jin
Wang He
Wang Weiping
Zhu Hongyu
Zhou Yin
Dai Jianrong
Men Kuo
collection Wiley Open Access
contents Development of a proof‐of‐concept treatment planning system for multi‐beam photon FLASH intensity modulated radiation therapy Guo Chenlei Cui Weijie Zha Hao Zhu Meng Ye Jin Wang He Wang Weiping Zhu Hongyu Zhou Yin Dai Jianrong Men Kuo Medical Physics Abstract Background The development of FLASH radiotherapy has gained attention for its potential to deliver high doses in very short treatment times, minimizing damage to normal tissues. Purpose This study developed and evaluated FLASHPlan, a treatment planning system (TPS) for multi‐beam photon FLASH (XFLASH) therapy. Methods FLASHPlan integrates the Fractional Combination Radiotherapy (FCRT) strategy with voxel‐level biological correction, using an organ‐specific dose‐modifying factor model and biologically effective dose (BED)‐based summation, under ultra‐high dose rate constraints. FCRT distributes clinically required beam angles across multiple fractions, delivering fixed static beams per session with inter‐fractional gantry reconfiguration. Fifty stereotactic body radiotherapy cases (single‐target brain, multifocal brain, lung, pancreas, and concave‐type prostate; 45 Gy in 3 fractions) were retrospectively replanned using FCRT and compared with conventional five static‐beam plans (Conv_5F). Dose‐volume metrics were reported on a common equivalent‐dose scale, and a passing rate (PR) was defined as the percentage of cases meeting SBRT constraints. Sensitivity analyses varied organ‐specific λ and the assumed FLASH plateau dose‐rate between 40 and 200 Gy/s. Results Compared with Conv_5F, FCRT modestly increased mean gross tumor volume (GTV) V45Gy in all cohorts and raised PR for V45Gy ≥ 95% from 10%–80% to 100% (all p  < 0.05). On DMF‐modified equivalent‐dose distributions, FCRT improved conformity index (CI) and reduced gradient index (GI) and high‐dose spillage in every cohort (all p  < 0.05), indicating tighter high‐dose regions and steeper dose fall‐off. High‐dose exposure to critical CNS, thoracic, abdominal, and pelvic organs‐at‐risk (OARs) was reduced, with PR for the most restrictive OAR constraints reaching 100%, while Lyman‐Kutcher‐Burman‐based normal tissue complication probability estimates for lung and brainstem changed minimally and remained within clinically acceptable ranges. In all λ and dose‐rate sensitivity scenarios, cohort‐averaged FCRT OAR doses varied only modestly and the dosimetric advantage of FCRT over Conv_5F was preserved. Conclusions FLASHPlan establishes a proof‐of‐concept TPS framework for multi‐beam XFLASH by combining geometry‐aware FCRT delivery with biology‐aware DMF/BED dose evaluation. Rather than demonstrating therapeutic superiority of FLASH‐RT, this work provides a planning infrastructure to support future XFLASH system development, radiobiological modeling, and clinical translation. 10.1002/mp.70331 http://onlinelibrary.wiley.com/termsAndConditions#vor
doi_str_mv 10.1002/mp.70331
format Artículo Open Access
id wiley_oa_10_1002_mp_70331
institution Wiley Open Access
license_str_mv http://onlinelibrary.wiley.com/termsAndConditions#vor
publishDate 2026
publisher Wiley
record_format wiley_oa
spellingShingle Development of a proof‐of‐concept treatment planning system for multi‐beam photon FLASH intensity modulated radiation therapy
Guo Chenlei
Cui Weijie
Zha Hao
Zhu Meng
Ye Jin
Wang He
Wang Weiping
Zhu Hongyu
Zhou Yin
Dai Jianrong
Men Kuo
Medical Physics
Development of a proof‐of‐concept treatment planning system for multi‐beam photon FLASH intensity modulated radiation therapy Guo Chenlei Cui Weijie Zha Hao Zhu Meng Ye Jin Wang He Wang Weiping Zhu Hongyu Zhou Yin Dai Jianrong Men Kuo Medical Physics Abstract Background The development of FLASH radiotherapy has gained attention for its potential to deliver high doses in very short treatment times, minimizing damage to normal tissues. Purpose This study developed and evaluated FLASHPlan, a treatment planning system (TPS) for multi‐beam photon FLASH (XFLASH) therapy. Methods FLASHPlan integrates the Fractional Combination Radiotherapy (FCRT) strategy with voxel‐level biological correction, using an organ‐specific dose‐modifying factor model and biologically effective dose (BED)‐based summation, under ultra‐high dose rate constraints. FCRT distributes clinically required beam angles across multiple fractions, delivering fixed static beams per session with inter‐fractional gantry reconfiguration. Fifty stereotactic body radiotherapy cases (single‐target brain, multifocal brain, lung, pancreas, and concave‐type prostate; 45 Gy in 3 fractions) were retrospectively replanned using FCRT and compared with conventional five static‐beam plans (Conv_5F). Dose‐volume metrics were reported on a common equivalent‐dose scale, and a passing rate (PR) was defined as the percentage of cases meeting SBRT constraints. Sensitivity analyses varied organ‐specific λ and the assumed FLASH plateau dose‐rate between 40 and 200 Gy/s. Results Compared with Conv_5F, FCRT modestly increased mean gross tumor volume (GTV) V45Gy in all cohorts and raised PR for V45Gy ≥ 95% from 10%–80% to 100% (all p  < 0.05). On DMF‐modified equivalent‐dose distributions, FCRT improved conformity index (CI) and reduced gradient index (GI) and high‐dose spillage in every cohort (all p  < 0.05), indicating tighter high‐dose regions and steeper dose fall‐off. High‐dose exposure to critical CNS, thoracic, abdominal, and pelvic organs‐at‐risk (OARs) was reduced, with PR for the most restrictive OAR constraints reaching 100%, while Lyman‐Kutcher‐Burman‐based normal tissue complication probability estimates for lung and brainstem changed minimally and remained within clinically acceptable ranges. In all λ and dose‐rate sensitivity scenarios, cohort‐averaged FCRT OAR doses varied only modestly and the dosimetric advantage of FCRT over Conv_5F was preserved. Conclusions FLASHPlan establishes a proof‐of‐concept TPS framework for multi‐beam XFLASH by combining geometry‐aware FCRT delivery with biology‐aware DMF/BED dose evaluation. Rather than demonstrating therapeutic superiority of FLASH‐RT, this work provides a planning infrastructure to support future XFLASH system development, radiobiological modeling, and clinical translation. 10.1002/mp.70331 http://onlinelibrary.wiley.com/termsAndConditions#vor
title Development of a proof‐of‐concept treatment planning system for multi‐beam photon FLASH intensity modulated radiation therapy
topic Medical Physics
url https://aapm.onlinelibrary.wiley.com/doi/10.1002/mp.70331