Pure Gaussian Apodisation Reduces Integral Crosstalk Sensitivity in Quantitative NMR
Fuente:
Wiley Open Access
Gespeichert in:
| Hauptverfasser: | , , |
|---|---|
| Format: | Artículo Open Access |
| Veröffentlicht: |
Wiley
2026
|
| Schlagworte: | |
| Online-Zugang: | |
| Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
| _version_ | 1867017782574448641 |
|---|---|
| author | A. Flook C. S. Raman G. C. Lloyd‐Jones |
| author_facet | A. Flook C. S. Raman G. C. Lloyd‐Jones A. Flook C. S. Raman G. C. Lloyd‐Jones |
| collection | Wiley Open Access |
| contents | Pure Gaussian Apodisation Reduces Integral Crosstalk Sensitivity in Quantitative NMR A. Flook C. S. Raman G. C. Lloyd‐Jones Magnetic Resonance in Chemistry ABSTRACT Exponential apodisation is routinely applied in quantitative NMR measurements to increase signal‐to‐noise ratio (SNR) and integral precision, with a peak broadening effect. However, apodisation suitability is typically evaluated using SNR and peak broadening metrics and does not consider how apodisation alters peak area distribution. Here, we assess how exponential apodisation extends peak wings and relocates area away from the peak centre. This necessitates larger integral regions to account for the same area, increasing the potential for peak overlap and introducing variability in the trueness of the measurement. As an alternative, we show that a pure Gaussian apodisation can deliver comparable SNR improvements to the common exponential apodisation when tuned to a matched broadening criterion, reducing overlap of peak wings and improving robustness of finite‐window integration. As a result, the narrower line width prior to apodisation can be used to guide appropriate integral region choice. Overall, a pure Gaussian apodisation is demonstrated to be a robust alternative to exponential apodisation, especially in conjunction with complex 1D NMR spectra. 10.1002/mrc.70113 http://creativecommons.org/licenses/by/4.0/ |
| doi_str_mv | 10.1002/mrc.70113 |
| format | Artículo Open Access |
| id | wiley_oa_10_1002_mrc_70113 |
| institution | Wiley Open Access |
| license_str_mv | http://creativecommons.org/licenses/by/4.0/ |
| publishDate | 2026 |
| publisher | Wiley |
| record_format | wiley_oa |
| spellingShingle | Pure Gaussian Apodisation Reduces Integral Crosstalk Sensitivity in Quantitative NMR A. Flook C. S. Raman G. C. Lloyd‐Jones Magnetic Resonance in Chemistry Pure Gaussian Apodisation Reduces Integral Crosstalk Sensitivity in Quantitative NMR A. Flook C. S. Raman G. C. Lloyd‐Jones Magnetic Resonance in Chemistry ABSTRACT Exponential apodisation is routinely applied in quantitative NMR measurements to increase signal‐to‐noise ratio (SNR) and integral precision, with a peak broadening effect. However, apodisation suitability is typically evaluated using SNR and peak broadening metrics and does not consider how apodisation alters peak area distribution. Here, we assess how exponential apodisation extends peak wings and relocates area away from the peak centre. This necessitates larger integral regions to account for the same area, increasing the potential for peak overlap and introducing variability in the trueness of the measurement. As an alternative, we show that a pure Gaussian apodisation can deliver comparable SNR improvements to the common exponential apodisation when tuned to a matched broadening criterion, reducing overlap of peak wings and improving robustness of finite‐window integration. As a result, the narrower line width prior to apodisation can be used to guide appropriate integral region choice. Overall, a pure Gaussian apodisation is demonstrated to be a robust alternative to exponential apodisation, especially in conjunction with complex 1D NMR spectra. 10.1002/mrc.70113 http://creativecommons.org/licenses/by/4.0/ |
| title | Pure Gaussian Apodisation Reduces Integral Crosstalk Sensitivity in Quantitative NMR |
| topic | Magnetic Resonance in Chemistry |
| url | https://analyticalsciencejournals.onlinelibrary.wiley.com/doi/10.1002/mrc.70113 |