Retrospective correction of second‐order concomitant fields in 3D axial stack‐of‐spirals imaging on a high‐performance gradient system

Fuente: Wiley Open Access
Guardado en:
Detalles Bibliográficos
Autores principales: Afis Ajala, Nastaren Abad, Thomas K. F. Foo, Seung‐Kyun Lee
Formato: Artículo Open Access
Publicado: Wiley 2024
Materias:
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1867014082142404608
author Afis Ajala
Nastaren Abad
Thomas K. F. Foo
Seung‐Kyun Lee
author_facet Afis Ajala
Nastaren Abad
Thomas K. F. Foo
Seung‐Kyun Lee
Afis Ajala
Nastaren Abad
Thomas K. F. Foo
Seung‐Kyun Lee
collection Wiley Open Access
contents Retrospective correction of second‐order concomitant fields in 3D axial stack‐of‐spirals imaging on a high‐performance gradient system Afis Ajala Nastaren Abad Thomas K. F. Foo Seung‐Kyun Lee Magnetic Resonance in Medicine AbstractPurposeMRI using 3D stack‐of‐spirals (SoS) readout on a high‐performance gradient system is subject to strong second‐order, spatially varying concomitant fields, which can lead to signal dropout and blurring artifacts that become more significant at locations farther from the gradient isocenter. A method for compensating for second‐order concomitant fields in 3D axial SoS image reconstruction is described.MethodsWe retrospectively correct for second‐order concomitant field–induced phase error in the 3D SoS data by slice‐dependent k‐space phase compensation based on the nominal spiral readout trajectories. The effectiveness of the method was demonstrated in phantom and healthy volunteer scans in which 3D pseudo‐continuous arterial spin labeling imaging was performed with SoS fast spin‐echo readout at 3 T.ResultsSubstantial reduction in blurring was observed with the proposed method. In phantom scans, blurring was reduced by about 53% at 98 mm from the gradient isocenter. In the in vivo 3D pseudo‐continuous arterial spin labeling scans, differences of up to 10% were observed at 78 mm from the isocenter, especially around the white‐matter and gray‐matter interfaces, between the corrected and uncorrected proton density images, perfusion‐weighted images, and cerebral blood flow maps.ConclusionsThe described retrospective correction method provides a means to correct erroneous phase accruals due to second‐order concomitant fields in 3D axial stack‐of‐spirals imaging. 10.1002/mrm.30113 http://onlinelibrary.wiley.com/termsAndConditions#vor
doi_str_mv 10.1002/mrm.30113
format Artículo Open Access
id wiley_oa_10_1002_mrm_30113
institution Wiley Open Access
license_str_mv http://onlinelibrary.wiley.com/termsAndConditions#vor
publishDate 2024
publisher Wiley
record_format wiley_oa
spellingShingle Retrospective correction of second‐order concomitant fields in 3D axial stack‐of‐spirals imaging on a high‐performance gradient system
Afis Ajala
Nastaren Abad
Thomas K. F. Foo
Seung‐Kyun Lee
Magnetic Resonance in Medicine
Retrospective correction of second‐order concomitant fields in 3D axial stack‐of‐spirals imaging on a high‐performance gradient system Afis Ajala Nastaren Abad Thomas K. F. Foo Seung‐Kyun Lee Magnetic Resonance in Medicine AbstractPurposeMRI using 3D stack‐of‐spirals (SoS) readout on a high‐performance gradient system is subject to strong second‐order, spatially varying concomitant fields, which can lead to signal dropout and blurring artifacts that become more significant at locations farther from the gradient isocenter. A method for compensating for second‐order concomitant fields in 3D axial SoS image reconstruction is described.MethodsWe retrospectively correct for second‐order concomitant field–induced phase error in the 3D SoS data by slice‐dependent k‐space phase compensation based on the nominal spiral readout trajectories. The effectiveness of the method was demonstrated in phantom and healthy volunteer scans in which 3D pseudo‐continuous arterial spin labeling imaging was performed with SoS fast spin‐echo readout at 3 T.ResultsSubstantial reduction in blurring was observed with the proposed method. In phantom scans, blurring was reduced by about 53% at 98 mm from the gradient isocenter. In the in vivo 3D pseudo‐continuous arterial spin labeling scans, differences of up to 10% were observed at 78 mm from the isocenter, especially around the white‐matter and gray‐matter interfaces, between the corrected and uncorrected proton density images, perfusion‐weighted images, and cerebral blood flow maps.ConclusionsThe described retrospective correction method provides a means to correct erroneous phase accruals due to second‐order concomitant fields in 3D axial stack‐of‐spirals imaging. 10.1002/mrm.30113 http://onlinelibrary.wiley.com/termsAndConditions#vor
title Retrospective correction of second‐order concomitant fields in 3D axial stack‐of‐spirals imaging on a high‐performance gradient system
topic Magnetic Resonance in Medicine
url https://onlinelibrary.wiley.com/doi/10.1002/mrm.30113