Monitoring the head exposure of MRI workers around 3 T, 7 T, and 11.7 T scanners using smart goggles equipped with a network of magnetometers

Fuente: Wiley Open Access
Enregistré dans:
Détails bibliographiques
Auteurs principaux: Hugo Nicolas, Corentin Féry, Thomas Quirin, Nicolas Weber, Julien Oster, Jacques Felblinger, Alexandre Vignaud, Joris Pascal
Format: Artículo Open Access
Publié: Wiley 2025
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1867019003278393346
author Hugo Nicolas
Corentin Féry
Thomas Quirin
Nicolas Weber
Julien Oster
Jacques Felblinger
Alexandre Vignaud
Joris Pascal
author_facet Hugo Nicolas
Corentin Féry
Thomas Quirin
Nicolas Weber
Julien Oster
Jacques Felblinger
Alexandre Vignaud
Joris Pascal
Hugo Nicolas
Corentin Féry
Thomas Quirin
Nicolas Weber
Julien Oster
Jacques Felblinger
Alexandre Vignaud
Joris Pascal
collection Wiley Open Access
contents Monitoring the head exposure of MRI workers around 3 T, 7 T, and 11.7 T scanners using smart goggles equipped with a network of magnetometers Hugo Nicolas Corentin Féry Thomas Quirin Nicolas Weber Julien Oster Jacques Felblinger Alexandre Vignaud Joris Pascal Magnetic Resonance in Medicine Abstract Purpose The aim of this paper is to introduce a new magnetic field exposimeter device that consists of goggles equipped with magnetic sensors for the assessment of the field exposure of MRI workers' heads. This is not possible with conventional pocket exposimeters. Hence, this device allows head‐level field exposure to be measured, which can induce physiological effects on MRI workers, and which are required to be covered by managing the laboratory‐related safety hazards directive 2013/35/EU. Methods Using on‐chip monolithic three‐axis Hall effect magnetometers, recently introduced on the market, we developed an exposimeter with unprecedented accuracy, which allows the measurement of the magnetic field closed to the organs which are the most impacted by strong magnetic fields: the brain, the eyes, and the tongue. Results The exposimeter prototypes were successfully tested around 3 T, 7 T, and 11.7 T MRI scanners on different workers and volunteers in real conditions. Comparisons with chest‐level measurements lead typically to lower values than exposure recorded at the head‐level, confirming the need for such head‐level assessments. Exposure of the head above the limits established by the directive was also recorded (>2 T or >2.7 T/s). Conclusion This new exposimeter allows for a more accurate assessment of field exposure of MRI workers. Further improvements in the miniaturization and the usability of the exposimeter will allow us to disseminate the device and open the way to a larger‐scale study. 10.1002/mrm.30513 http://creativecommons.org/licenses/by/4.0/
doi_str_mv 10.1002/mrm.30513
format Artículo Open Access
id wiley_oa_10_1002_mrm_30513
institution Wiley Open Access
license_str_mv http://creativecommons.org/licenses/by/4.0/
publishDate 2025
publisher Wiley
record_format wiley_oa
spellingShingle Monitoring the head exposure of MRI workers around 3 T, 7 T, and 11.7 T scanners using smart goggles equipped with a network of magnetometers
Hugo Nicolas
Corentin Féry
Thomas Quirin
Nicolas Weber
Julien Oster
Jacques Felblinger
Alexandre Vignaud
Joris Pascal
Magnetic Resonance in Medicine
Monitoring the head exposure of MRI workers around 3 T, 7 T, and 11.7 T scanners using smart goggles equipped with a network of magnetometers Hugo Nicolas Corentin Féry Thomas Quirin Nicolas Weber Julien Oster Jacques Felblinger Alexandre Vignaud Joris Pascal Magnetic Resonance in Medicine Abstract Purpose The aim of this paper is to introduce a new magnetic field exposimeter device that consists of goggles equipped with magnetic sensors for the assessment of the field exposure of MRI workers' heads. This is not possible with conventional pocket exposimeters. Hence, this device allows head‐level field exposure to be measured, which can induce physiological effects on MRI workers, and which are required to be covered by managing the laboratory‐related safety hazards directive 2013/35/EU. Methods Using on‐chip monolithic three‐axis Hall effect magnetometers, recently introduced on the market, we developed an exposimeter with unprecedented accuracy, which allows the measurement of the magnetic field closed to the organs which are the most impacted by strong magnetic fields: the brain, the eyes, and the tongue. Results The exposimeter prototypes were successfully tested around 3 T, 7 T, and 11.7 T MRI scanners on different workers and volunteers in real conditions. Comparisons with chest‐level measurements lead typically to lower values than exposure recorded at the head‐level, confirming the need for such head‐level assessments. Exposure of the head above the limits established by the directive was also recorded (>2 T or >2.7 T/s). Conclusion This new exposimeter allows for a more accurate assessment of field exposure of MRI workers. Further improvements in the miniaturization and the usability of the exposimeter will allow us to disseminate the device and open the way to a larger‐scale study. 10.1002/mrm.30513 http://creativecommons.org/licenses/by/4.0/
title Monitoring the head exposure of MRI workers around 3 T, 7 T, and 11.7 T scanners using smart goggles equipped with a network of magnetometers
topic Magnetic Resonance in Medicine
url https://onlinelibrary.wiley.com/doi/10.1002/mrm.30513