Quadruple‐refocused spin‐locking: A robust method for high‐amplitude T1ρ imaging

Fuente: Wiley Open Access
Saved in:
Bibliographic Details
Main Authors: Cai Wan, Maximilian Gram, Wei He, Zheng Xu, Qingping Chen, Sebastian Littin, Thomas Lange, Maxim Zaitsev
Format: Artículo Open Access
Published: Wiley 2025
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1867013619732971520
author Cai Wan
Maximilian Gram
Wei He
Zheng Xu
Qingping Chen
Sebastian Littin
Thomas Lange
Maxim Zaitsev
author_facet Cai Wan
Maximilian Gram
Wei He
Zheng Xu
Qingping Chen
Sebastian Littin
Thomas Lange
Maxim Zaitsev
Cai Wan
Maximilian Gram
Wei He
Zheng Xu
Qingping Chen
Sebastian Littin
Thomas Lange
Maxim Zaitsev
collection Wiley Open Access
contents Quadruple‐refocused spin‐locking: A robust method for high‐amplitude T1ρ imaging Cai Wan Maximilian Gram Wei He Zheng Xu Qingping Chen Sebastian Littin Thomas Lange Maxim Zaitsev Magnetic Resonance in Medicine AbstractPurposeLongitudinal relaxation time in the rotating frame (T1ρ) is a source of tissue‐specific contrasts, with applications in detecting myocardial fibrosis, liver fibrosis, and early‐stage osteoarthritis. However, T1ρ measurements are sensitive to static (B0) and radiofrequency (B1) magnetic field inhomogeneities. Improving the accuracy of T1ρ quantification can enable earlier and more reliable detection of pathological changes, providing a basis for early intervention. Therefore, we have developed an improved, quadruple‐refocused spin‐locking (QR‐SL) technique based on existing preparation schemes to obtain a more robust compensation for B0 and B1 field inhomogeneities.MethodsThe QR‐SL module consists of four 180° refocusing pulses with opposite phases and five spin‐locking (SL) pulses with phase cycling according to the rotary‐echo principle. The performance of the proposed QR‐SL module is evaluated through numerical simulations and experimental validation in comparison to composite‐SL (C‐SL), balanced‐SL (B‐SL), and triple‐refocused‐SL (TR‐SL) preparation modules.ResultsNumerical simulations indicate that the QR‐SL module demonstrates improved tolerance to a range of B0 and B1 field inhomogeneities compared to the other three modules. In scenarios involving inhomogeneities of both fields, the experimental results show that the residual sum of squares of the QR‐SL module was decreased by 24.3%, 68.9%, and 12.5% for in vivo knee cartilage, respectively, compared to the composite SL, balanced SL, and triple‐refocused SL preparation modules.ConclusionThe QR‐SL module has the potential to produce more accurate T1ρ maps, while minimizing artifacts. Consequently, the QR‐SL module is more favorable for T1ρ quantification, especially for low‐field and ultralow‐field quantitative MRI. 10.1002/mrm.30621 http://creativecommons.org/licenses/by/4.0/
doi_str_mv 10.1002/mrm.30621
format Artículo Open Access
id wiley_oa_10_1002_mrm_30621
institution Wiley Open Access
license_str_mv http://creativecommons.org/licenses/by/4.0/
publishDate 2025
publisher Wiley
record_format wiley_oa
spellingShingle Quadruple‐refocused spin‐locking: A robust method for high‐amplitude T1ρ imaging
Cai Wan
Maximilian Gram
Wei He
Zheng Xu
Qingping Chen
Sebastian Littin
Thomas Lange
Maxim Zaitsev
Magnetic Resonance in Medicine
Quadruple‐refocused spin‐locking: A robust method for high‐amplitude T1ρ imaging Cai Wan Maximilian Gram Wei He Zheng Xu Qingping Chen Sebastian Littin Thomas Lange Maxim Zaitsev Magnetic Resonance in Medicine AbstractPurposeLongitudinal relaxation time in the rotating frame (T1ρ) is a source of tissue‐specific contrasts, with applications in detecting myocardial fibrosis, liver fibrosis, and early‐stage osteoarthritis. However, T1ρ measurements are sensitive to static (B0) and radiofrequency (B1) magnetic field inhomogeneities. Improving the accuracy of T1ρ quantification can enable earlier and more reliable detection of pathological changes, providing a basis for early intervention. Therefore, we have developed an improved, quadruple‐refocused spin‐locking (QR‐SL) technique based on existing preparation schemes to obtain a more robust compensation for B0 and B1 field inhomogeneities.MethodsThe QR‐SL module consists of four 180° refocusing pulses with opposite phases and five spin‐locking (SL) pulses with phase cycling according to the rotary‐echo principle. The performance of the proposed QR‐SL module is evaluated through numerical simulations and experimental validation in comparison to composite‐SL (C‐SL), balanced‐SL (B‐SL), and triple‐refocused‐SL (TR‐SL) preparation modules.ResultsNumerical simulations indicate that the QR‐SL module demonstrates improved tolerance to a range of B0 and B1 field inhomogeneities compared to the other three modules. In scenarios involving inhomogeneities of both fields, the experimental results show that the residual sum of squares of the QR‐SL module was decreased by 24.3%, 68.9%, and 12.5% for in vivo knee cartilage, respectively, compared to the composite SL, balanced SL, and triple‐refocused SL preparation modules.ConclusionThe QR‐SL module has the potential to produce more accurate T1ρ maps, while minimizing artifacts. Consequently, the QR‐SL module is more favorable for T1ρ quantification, especially for low‐field and ultralow‐field quantitative MRI. 10.1002/mrm.30621 http://creativecommons.org/licenses/by/4.0/
title Quadruple‐refocused spin‐locking: A robust method for high‐amplitude T1ρ imaging
topic Magnetic Resonance in Medicine
url https://onlinelibrary.wiley.com/doi/10.1002/mrm.30621