Field‐Based Spatial Self‐Registration of Multicoil Hardware for B 0 Field Control

Fuente: Wiley Open Access
Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Isabelle Zinghini, Ian Macleod, Carlotta Ianniello, Sebastian Theilenberg, Christoph Juchem
Format: Artículo Open Access
Veröffentlicht: Wiley 2026
Schlagworte:
Online-Zugang:
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
_version_ 1867006786769256448
author Isabelle Zinghini
Ian Macleod
Carlotta Ianniello
Sebastian Theilenberg
Christoph Juchem
author_facet Isabelle Zinghini
Ian Macleod
Carlotta Ianniello
Sebastian Theilenberg
Christoph Juchem
Isabelle Zinghini
Ian Macleod
Carlotta Ianniello
Sebastian Theilenberg
Christoph Juchem
collection Wiley Open Access
contents Field‐Based Spatial Self‐Registration of Multicoil Hardware for B 0 Field Control Isabelle Zinghini Ian Macleod Carlotta Ianniello Sebastian Theilenberg Christoph Juchem Magnetic Resonance in Medicine ABSTRACT Purpose To develop and validate a magnetic field‐based method for self‐registration of multicoil (MC) shim hardware in MRI systems, enabling accurate B 0 field control despite nonreproducible hardware placement between calibration and experimental sessions. Methods An algorithm was designed to estimate rigid transformations between 3D field maps acquired during hardware calibration (Reference field) and subsequent experiments (Measured field). Hardware misplacement was determined by co‐registration of the two fields within a defined region of interest. Simulations using Biot–Savart–derived MC basis fields and experimental validation with a 48‐channel MC array at 3 T were used to quantify localization accuracy under varying signal‐to‐noise ratio (SNR) levels. A genetic algorithm optimized coil currents to generate a Reference field shape that yielded minimal self‐registration error. Results Simulations and measurements demonstrated that submillimeter (≤ 0.5 mm) and subdegree (≤ 0.5°) localization accuracy is achievable at practical SNR levels (≥ 5). Errors decreased with increasing SNR and field complexity. The optimized field produced by the genetic algorithm yielded the lowest mean translation error (0.20 mm) and rotation error (0.11°), consistent with theoretical predictions. Self‐registration computation required less than 10 s per case. Conclusion The proposed field‐based self‐registration method enables rapid, accurate localization of MC shim hardware using only MR‐acquired field maps, eliminating the need for external tracking hardware or repeated calibrations. This approach enhances reproducibility of MC field control and supports improved B 0 shimming performance in insert‐based or repositionable MR systems. 10.1002/mrm.70413 http://creativecommons.org/licenses/by-nc/4.0/
doi_str_mv 10.1002/mrm.70413
format Artículo Open Access
id wiley_oa_10_1002_mrm_70413
institution Wiley Open Access
license_str_mv http://creativecommons.org/licenses/by-nc/4.0/
publishDate 2026
publisher Wiley
record_format wiley_oa
spellingShingle Field‐Based Spatial Self‐Registration of Multicoil Hardware for B 0 Field Control
Isabelle Zinghini
Ian Macleod
Carlotta Ianniello
Sebastian Theilenberg
Christoph Juchem
Magnetic Resonance in Medicine
Field‐Based Spatial Self‐Registration of Multicoil Hardware for B 0 Field Control Isabelle Zinghini Ian Macleod Carlotta Ianniello Sebastian Theilenberg Christoph Juchem Magnetic Resonance in Medicine ABSTRACT Purpose To develop and validate a magnetic field‐based method for self‐registration of multicoil (MC) shim hardware in MRI systems, enabling accurate B 0 field control despite nonreproducible hardware placement between calibration and experimental sessions. Methods An algorithm was designed to estimate rigid transformations between 3D field maps acquired during hardware calibration (Reference field) and subsequent experiments (Measured field). Hardware misplacement was determined by co‐registration of the two fields within a defined region of interest. Simulations using Biot–Savart–derived MC basis fields and experimental validation with a 48‐channel MC array at 3 T were used to quantify localization accuracy under varying signal‐to‐noise ratio (SNR) levels. A genetic algorithm optimized coil currents to generate a Reference field shape that yielded minimal self‐registration error. Results Simulations and measurements demonstrated that submillimeter (≤ 0.5 mm) and subdegree (≤ 0.5°) localization accuracy is achievable at practical SNR levels (≥ 5). Errors decreased with increasing SNR and field complexity. The optimized field produced by the genetic algorithm yielded the lowest mean translation error (0.20 mm) and rotation error (0.11°), consistent with theoretical predictions. Self‐registration computation required less than 10 s per case. Conclusion The proposed field‐based self‐registration method enables rapid, accurate localization of MC shim hardware using only MR‐acquired field maps, eliminating the need for external tracking hardware or repeated calibrations. This approach enhances reproducibility of MC field control and supports improved B 0 shimming performance in insert‐based or repositionable MR systems. 10.1002/mrm.70413 http://creativecommons.org/licenses/by-nc/4.0/
title Field‐Based Spatial Self‐Registration of Multicoil Hardware for B 0 Field Control
topic Magnetic Resonance in Medicine
url https://onlinelibrary.wiley.com/doi/10.1002/mrm.70413