Higher Force Metrics Associated With Known Risk Factors for Difficult Laryngeal Exposure

Fuente: Wiley Open Access
Enregistré dans:
Détails bibliographiques
Auteurs principaux: Lily Stevenson, Timothy Fenton, Allen Feng, Phillip Song
Format: Artículo Open Access
Publié: Wiley 2026
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1867019413361786880
author Lily Stevenson
Timothy Fenton
Allen Feng
Phillip Song
author_facet Lily Stevenson
Timothy Fenton
Allen Feng
Phillip Song
Lily Stevenson
Timothy Fenton
Allen Feng
Phillip Song
collection Wiley Open Access
contents Higher Force Metrics Associated With Known Risk Factors for Difficult Laryngeal Exposure Lily Stevenson Timothy Fenton Allen Feng Phillip Song Otolaryngology–Head and Neck Surgery Abstract Objective Several factors are reported as predictors of difficult laryngeal exposure (DLE). This study investigates force metrics associated with predictive factors of DLE during suspension microlaryngoscopy (SML) utilizing data recorded by the laryngeal force sensor (LFS). We hypothesize that patient factors associated with DLE will record higher forces during laryngeal surgery. Study Design Prospective observational cohort clinical trial data examining secondary endpoints. Setting Tertiary medical center. Methods The LFS recorded maximum force and average force during SML in 214 laryngeal surgeries. Patient characteristics, and perioperative factors such as interincisor distance (ID), Mallampati scores, cervical spine stiffness, thyromental (TM) distance, and laryngeal grade view during intubation, were also recorded. Results Patients included ranged from 19 to 90 years, with a median age of 57 years. A higher Mallampati score corresponded to a higher average force and maximum force ( P  = .002, P  = .003). Patients with an ID of ≤4.5 cm experienced nearly double the average force when compared to edentulous patients ( P  = .002). Height ( P  = .001) and a shorter TM distance were associated with higher force metrics. There was also a difference in force metrics between the sexes, with men experiencing a higher average force ( P  ≤ .001). Conclusion Elevated force metrics during SML are correlated with predictive indicators for difficult intubation and laryngeal exposure. These metrics could help identify patients at higher risk of requiring increased force during both intubation and SML, leading to potential postoperative complications. 10.1002/ohn.70180 http://onlinelibrary.wiley.com/termsAndConditions#vor
doi_str_mv 10.1002/ohn.70180
format Artículo Open Access
id wiley_oa_10_1002_ohn_70180
institution Wiley Open Access
license_str_mv http://onlinelibrary.wiley.com/termsAndConditions#vor
publishDate 2026
publisher Wiley
record_format wiley_oa
spellingShingle Higher Force Metrics Associated With Known Risk Factors for Difficult Laryngeal Exposure
Lily Stevenson
Timothy Fenton
Allen Feng
Phillip Song
Otolaryngology–Head and Neck Surgery
Higher Force Metrics Associated With Known Risk Factors for Difficult Laryngeal Exposure Lily Stevenson Timothy Fenton Allen Feng Phillip Song Otolaryngology–Head and Neck Surgery Abstract Objective Several factors are reported as predictors of difficult laryngeal exposure (DLE). This study investigates force metrics associated with predictive factors of DLE during suspension microlaryngoscopy (SML) utilizing data recorded by the laryngeal force sensor (LFS). We hypothesize that patient factors associated with DLE will record higher forces during laryngeal surgery. Study Design Prospective observational cohort clinical trial data examining secondary endpoints. Setting Tertiary medical center. Methods The LFS recorded maximum force and average force during SML in 214 laryngeal surgeries. Patient characteristics, and perioperative factors such as interincisor distance (ID), Mallampati scores, cervical spine stiffness, thyromental (TM) distance, and laryngeal grade view during intubation, were also recorded. Results Patients included ranged from 19 to 90 years, with a median age of 57 years. A higher Mallampati score corresponded to a higher average force and maximum force ( P  = .002, P  = .003). Patients with an ID of ≤4.5 cm experienced nearly double the average force when compared to edentulous patients ( P  = .002). Height ( P  = .001) and a shorter TM distance were associated with higher force metrics. There was also a difference in force metrics between the sexes, with men experiencing a higher average force ( P  ≤ .001). Conclusion Elevated force metrics during SML are correlated with predictive indicators for difficult intubation and laryngeal exposure. These metrics could help identify patients at higher risk of requiring increased force during both intubation and SML, leading to potential postoperative complications. 10.1002/ohn.70180 http://onlinelibrary.wiley.com/termsAndConditions#vor
title Higher Force Metrics Associated With Known Risk Factors for Difficult Laryngeal Exposure
topic Otolaryngology–Head and Neck Surgery
url https://aao-hnsfjournals.onlinelibrary.wiley.com/doi/10.1002/ohn.70180