Fluorescence Spectroscopy for Real‐Time Intraoperative Detection of Middle‐Ear Cholesteatoma

Fuente: Wiley Open Access
Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Joackim Mahdjoub, Olivier Gaiffe, Riham Altaisan, Nikolaos Zirganos, Nicolas Passilly, Bruno Wacogne, Emmanuel Ramasso, Laurent Tavernier
Format: Artículo Open Access
Veröffentlicht: Wiley 2026
Schlagworte:
Online-Zugang:
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
_version_ 1867002626166489089
author Joackim Mahdjoub
Olivier Gaiffe
Riham Altaisan
Nikolaos Zirganos
Nicolas Passilly
Bruno Wacogne
Emmanuel Ramasso
Laurent Tavernier
author_facet Joackim Mahdjoub
Olivier Gaiffe
Riham Altaisan
Nikolaos Zirganos
Nicolas Passilly
Bruno Wacogne
Emmanuel Ramasso
Laurent Tavernier
Joackim Mahdjoub
Olivier Gaiffe
Riham Altaisan
Nikolaos Zirganos
Nicolas Passilly
Bruno Wacogne
Emmanuel Ramasso
Laurent Tavernier
collection Wiley Open Access
contents Fluorescence Spectroscopy for Real‐Time Intraoperative Detection of Middle‐Ear Cholesteatoma Joackim Mahdjoub Olivier Gaiffe Riham Altaisan Nikolaos Zirganos Nicolas Passilly Bruno Wacogne Emmanuel Ramasso Laurent Tavernier Otolaryngology–Head and Neck Surgery Abstract Objective To evaluate whether autofluorescence spectroscopy (AFS) can reliably distinguish cholesteatoma from surrounding middle‐ear tissues, and to develop a real‐time intraoperative diagnostic tool. Study Design Prospective ex vivo study. Setting Besançon University Hospital, France (tertiary care center). Methods In this prospective ex vivo study, middle‐ear tissue biopsies were collected during cholesteatoma surgeries and analyzed using autofluorescence following 405‐nm laser excitation. Each sample was classified based on its spectral signature and confirmed by histopathology. A computer‐assisted model was applied to differentiate cholesteatoma from noncholesteatoma tissues, and its performance was assessed using standard cross‐validation. Results Thirty‐six tissue samples from 23 patients were analyzed, generating nearly 3800 fluorescence spectra. The model correctly classified all samples, achieving 94.5% accuracy, 94.7% sensitivity, and 94.2% specificity. The system provided consistent performance across tissue types and returned results in real time, with a response time of 0.1 seconds per sample. Each output included a probability score indicating the likelihood of cholesteatoma presence. Conclusion AFS demonstrated high accuracy in distinguishing cholesteatoma from other middle‐ear tissues. Its speed, simplicity, and probabilistic feedback suggest strong potential for real‐time intraoperative use. Once validated in vivo, this technology could assist surgeons by improving tissue discrimination and potentially reducing recurrence rates. 10.1002/ohn.70207 http://onlinelibrary.wiley.com/termsAndConditions#vor
doi_str_mv 10.1002/ohn.70207
format Artículo Open Access
id wiley_oa_10_1002_ohn_70207
institution Wiley Open Access
license_str_mv http://onlinelibrary.wiley.com/termsAndConditions#vor
publishDate 2026
publisher Wiley
record_format wiley_oa
spellingShingle Fluorescence Spectroscopy for Real‐Time Intraoperative Detection of Middle‐Ear Cholesteatoma
Joackim Mahdjoub
Olivier Gaiffe
Riham Altaisan
Nikolaos Zirganos
Nicolas Passilly
Bruno Wacogne
Emmanuel Ramasso
Laurent Tavernier
Otolaryngology–Head and Neck Surgery
Fluorescence Spectroscopy for Real‐Time Intraoperative Detection of Middle‐Ear Cholesteatoma Joackim Mahdjoub Olivier Gaiffe Riham Altaisan Nikolaos Zirganos Nicolas Passilly Bruno Wacogne Emmanuel Ramasso Laurent Tavernier Otolaryngology–Head and Neck Surgery Abstract Objective To evaluate whether autofluorescence spectroscopy (AFS) can reliably distinguish cholesteatoma from surrounding middle‐ear tissues, and to develop a real‐time intraoperative diagnostic tool. Study Design Prospective ex vivo study. Setting Besançon University Hospital, France (tertiary care center). Methods In this prospective ex vivo study, middle‐ear tissue biopsies were collected during cholesteatoma surgeries and analyzed using autofluorescence following 405‐nm laser excitation. Each sample was classified based on its spectral signature and confirmed by histopathology. A computer‐assisted model was applied to differentiate cholesteatoma from noncholesteatoma tissues, and its performance was assessed using standard cross‐validation. Results Thirty‐six tissue samples from 23 patients were analyzed, generating nearly 3800 fluorescence spectra. The model correctly classified all samples, achieving 94.5% accuracy, 94.7% sensitivity, and 94.2% specificity. The system provided consistent performance across tissue types and returned results in real time, with a response time of 0.1 seconds per sample. Each output included a probability score indicating the likelihood of cholesteatoma presence. Conclusion AFS demonstrated high accuracy in distinguishing cholesteatoma from other middle‐ear tissues. Its speed, simplicity, and probabilistic feedback suggest strong potential for real‐time intraoperative use. Once validated in vivo, this technology could assist surgeons by improving tissue discrimination and potentially reducing recurrence rates. 10.1002/ohn.70207 http://onlinelibrary.wiley.com/termsAndConditions#vor
title Fluorescence Spectroscopy for Real‐Time Intraoperative Detection of Middle‐Ear Cholesteatoma
topic Otolaryngology–Head and Neck Surgery
url https://aao-hnsfjournals.onlinelibrary.wiley.com/doi/10.1002/ohn.70207