Evaluating intra‐fraction motion and its dosimetric impact in ethos online adaptive radiotherapy for prostate cancer

Fuente: Wiley Open Access
Salvato in:
Dettagli Bibliografici
Autori principali: Yoganathan SA, Ahamed Basith, Rajeev Choudary Apsani, Venkada Manickam Gurusamy, Amine Khemissi, Satheesh Paloor, Saju Divakar, Sarah McCabe, Rabih Hammoud, Noora Al‐Hammadi
Natura: Artículo Open Access
Pubblicazione: Wiley 2025
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1867007155740082176
author Yoganathan SA
Ahamed Basith
Rajeev Choudary Apsani
Venkada Manickam Gurusamy
Amine Khemissi
Satheesh Paloor
Saju Divakar
Sarah McCabe
Rabih Hammoud
Noora Al‐Hammadi
author_facet Yoganathan SA
Ahamed Basith
Rajeev Choudary Apsani
Venkada Manickam Gurusamy
Amine Khemissi
Satheesh Paloor
Saju Divakar
Sarah McCabe
Rabih Hammoud
Noora Al‐Hammadi
Yoganathan SA
Ahamed Basith
Rajeev Choudary Apsani
Venkada Manickam Gurusamy
Amine Khemissi
Satheesh Paloor
Saju Divakar
Sarah McCabe
Rabih Hammoud
Noora Al‐Hammadi
collection Wiley Open Access
contents Evaluating intra‐fraction motion and its dosimetric impact in ethos online adaptive radiotherapy for prostate cancer Yoganathan SA Ahamed Basith Rajeev Choudary Apsani Venkada Manickam Gurusamy Amine Khemissi Satheesh Paloor Saju Divakar Sarah McCabe Rabih Hammoud Noora Al‐Hammadi Precision Radiation Oncology AbstractPurposeThis study evaluated the geometric and dosimetric uncertainties during online adaptive radiotherapy (ART) for prostate cancer.MethodsSequential cone beam computed tomography (CBCT) scans from 52 sessions involving 13 patients were analyzed. An ART plan was generated using CBCT1, followed by a verification scan (CBCT2) acquired 13.1 ± 3.0 minutes before treatment delivery. New contours (prostate, seminal vesicles, bladder, rectum, and bowel) were delineated on CBCT2 and transferred to CBCT1 for dose distribution analysis. Three dimensional contour variations were quantified, new planning target volume (PTV) margins were calculated, and their dosimetric benefits were assessed.ResultsNo significant differences were observed in the high‐dose volumes (V60 Gy and V57 Gy) of the bladder and rectum (P > 0.05). PTV margins were 2.6 mm, 2.4 mm, and 2.6 mm in the lateral, vertical, and longitudinal directions for the prostate, and 3.9 mm, 3.8 mm, and 4.3 mm for the seminal vesicles, respectively. These margin reductions led to a 37% reduction in the dose to the surrounding critical organs, while maintaining consistent target coverage.ConclusionThis study supports symmetric PTV margins of 3 mm for the prostate and 4.5 mm for the seminal vesicles in online ART, thereby contributing to the development of optimized treatment strategies for prostate cancer. 10.1002/pro6.70013 http://creativecommons.org/licenses/by/4.0/
doi_str_mv 10.1002/pro6.70013
format Artículo Open Access
id wiley_oa_10_1002_pro6_70013
institution Wiley Open Access
license_str_mv http://creativecommons.org/licenses/by/4.0/
publishDate 2025
publisher Wiley
record_format wiley_oa
spellingShingle Evaluating intra‐fraction motion and its dosimetric impact in ethos online adaptive radiotherapy for prostate cancer
Yoganathan SA
Ahamed Basith
Rajeev Choudary Apsani
Venkada Manickam Gurusamy
Amine Khemissi
Satheesh Paloor
Saju Divakar
Sarah McCabe
Rabih Hammoud
Noora Al‐Hammadi
Precision Radiation Oncology
Evaluating intra‐fraction motion and its dosimetric impact in ethos online adaptive radiotherapy for prostate cancer Yoganathan SA Ahamed Basith Rajeev Choudary Apsani Venkada Manickam Gurusamy Amine Khemissi Satheesh Paloor Saju Divakar Sarah McCabe Rabih Hammoud Noora Al‐Hammadi Precision Radiation Oncology AbstractPurposeThis study evaluated the geometric and dosimetric uncertainties during online adaptive radiotherapy (ART) for prostate cancer.MethodsSequential cone beam computed tomography (CBCT) scans from 52 sessions involving 13 patients were analyzed. An ART plan was generated using CBCT1, followed by a verification scan (CBCT2) acquired 13.1 ± 3.0 minutes before treatment delivery. New contours (prostate, seminal vesicles, bladder, rectum, and bowel) were delineated on CBCT2 and transferred to CBCT1 for dose distribution analysis. Three dimensional contour variations were quantified, new planning target volume (PTV) margins were calculated, and their dosimetric benefits were assessed.ResultsNo significant differences were observed in the high‐dose volumes (V60 Gy and V57 Gy) of the bladder and rectum (P > 0.05). PTV margins were 2.6 mm, 2.4 mm, and 2.6 mm in the lateral, vertical, and longitudinal directions for the prostate, and 3.9 mm, 3.8 mm, and 4.3 mm for the seminal vesicles, respectively. These margin reductions led to a 37% reduction in the dose to the surrounding critical organs, while maintaining consistent target coverage.ConclusionThis study supports symmetric PTV margins of 3 mm for the prostate and 4.5 mm for the seminal vesicles in online ART, thereby contributing to the development of optimized treatment strategies for prostate cancer. 10.1002/pro6.70013 http://creativecommons.org/licenses/by/4.0/
title Evaluating intra‐fraction motion and its dosimetric impact in ethos online adaptive radiotherapy for prostate cancer
topic Precision Radiation Oncology
url https://onlinelibrary.wiley.com/doi/10.1002/pro6.70013