Machine Learning‐Driven Capillary Microfluidic Design Automation for Programmable Gradient Generation and Antimicrobial Testing

Fuente: Wiley Open Access
Salvato in:
Dettagli Bibliografici
Autori principali: Mahmood Khalghollah, Azam Zare, Sorosh Abdollahi, Behrouz H. Far, Amir Sanati Nezhad
Natura: Artículo Open Access
Pubblicazione: Wiley 2026
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1867017972549156864
author Mahmood Khalghollah
Azam Zare
Sorosh Abdollahi
Behrouz H. Far
Amir Sanati Nezhad
author_facet Mahmood Khalghollah
Azam Zare
Sorosh Abdollahi
Behrouz H. Far
Amir Sanati Nezhad
Mahmood Khalghollah
Azam Zare
Sorosh Abdollahi
Behrouz H. Far
Amir Sanati Nezhad
collection Wiley Open Access
contents Machine Learning‐Driven Capillary Microfluidic Design Automation for Programmable Gradient Generation and Antimicrobial Testing Mahmood Khalghollah Azam Zare Sorosh Abdollahi Behrouz H. Far Amir Sanati Nezhad Small ABSTRACT Rapid, portable, and automated determination of minimum inhibitory concentration (MIC) is critical for antimicrobial susceptibility testing in decentralized settings. We present TCG‐CMDA (Tree‐Shaped Concentration Gradient generator enabled by Capillary Microfluidic Design Automation), a machine learning–guided platform for the automated design of capillary microfluidic chips that passively generate programmable concentration gradients. A key innovation of TCG‐CMDA is its ability to achieve fully synchronized, capillary‐driven flow of two preloaded agents, enabling precise and reproducible gradient formation without external pumps or valves. By integrating computational fluid dynamics (CFD) simulations, a neural network surrogate model, and quasi‐Newton optimization, the platform customizes tree‐shaped geometries to match target mixing profiles. We validate TCG‐CMDA through dye flow visualization and MIC testing of Escherichia coli against gentamicin, showing high concordance with conventional antibiotic susceptibility testing. The resulting chip supports a streamlined workflow consisting of passive loading, autonomous gradient generation, and incubation (∼2 h), followed by direct endpoint assessment, making it well suited for decentralized point‐of‐care applications. TCG‐CMDA establishes a closed‐loop, simulation‐guided design paradigm for capillary microfluidic systems. Although demonstrated here for MIC‐oriented antimicrobial testing, the framework is generalizable and can be extended to other gradient‐dependent microfluidic applications through geometry reconfiguration and fluid‐specific optimization. 10.1002/smll.73821 http://creativecommons.org/licenses/by-nc-nd/4.0/
doi_str_mv 10.1002/smll.73821
format Artículo Open Access
id wiley_oa_10_1002_smll_73821
institution Wiley Open Access
license_str_mv http://creativecommons.org/licenses/by-nc-nd/4.0/
publishDate 2026
publisher Wiley
record_format wiley_oa
spellingShingle Machine Learning‐Driven Capillary Microfluidic Design Automation for Programmable Gradient Generation and Antimicrobial Testing
Mahmood Khalghollah
Azam Zare
Sorosh Abdollahi
Behrouz H. Far
Amir Sanati Nezhad
Small
Machine Learning‐Driven Capillary Microfluidic Design Automation for Programmable Gradient Generation and Antimicrobial Testing Mahmood Khalghollah Azam Zare Sorosh Abdollahi Behrouz H. Far Amir Sanati Nezhad Small ABSTRACT Rapid, portable, and automated determination of minimum inhibitory concentration (MIC) is critical for antimicrobial susceptibility testing in decentralized settings. We present TCG‐CMDA (Tree‐Shaped Concentration Gradient generator enabled by Capillary Microfluidic Design Automation), a machine learning–guided platform for the automated design of capillary microfluidic chips that passively generate programmable concentration gradients. A key innovation of TCG‐CMDA is its ability to achieve fully synchronized, capillary‐driven flow of two preloaded agents, enabling precise and reproducible gradient formation without external pumps or valves. By integrating computational fluid dynamics (CFD) simulations, a neural network surrogate model, and quasi‐Newton optimization, the platform customizes tree‐shaped geometries to match target mixing profiles. We validate TCG‐CMDA through dye flow visualization and MIC testing of Escherichia coli against gentamicin, showing high concordance with conventional antibiotic susceptibility testing. The resulting chip supports a streamlined workflow consisting of passive loading, autonomous gradient generation, and incubation (∼2 h), followed by direct endpoint assessment, making it well suited for decentralized point‐of‐care applications. TCG‐CMDA establishes a closed‐loop, simulation‐guided design paradigm for capillary microfluidic systems. Although demonstrated here for MIC‐oriented antimicrobial testing, the framework is generalizable and can be extended to other gradient‐dependent microfluidic applications through geometry reconfiguration and fluid‐specific optimization. 10.1002/smll.73821 http://creativecommons.org/licenses/by-nc-nd/4.0/
title Machine Learning‐Driven Capillary Microfluidic Design Automation for Programmable Gradient Generation and Antimicrobial Testing
topic Small
url https://onlinelibrary.wiley.com/doi/10.1002/smll.73821