Fourier‐transform infrared spectroscopy imaging is a useful adjunct to routine histopathology to identify failure of polyethylene inlays in revision total hip arthroplasty

Fuente: Wiley Open Access
Saved in:
Bibliographic Details
Main Authors: Songyun Liu, Deborah J. Hall, Corina Dommann‐Scherrer, Robin Pourzal, Peter Wahl
Format: Artículo Open Access
Published: Wiley 2024
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1867018583223042048
author Songyun Liu
Deborah J. Hall
Corina Dommann‐Scherrer
Robin Pourzal
Peter Wahl
author_facet Songyun Liu
Deborah J. Hall
Corina Dommann‐Scherrer
Robin Pourzal
Peter Wahl
Songyun Liu
Deborah J. Hall
Corina Dommann‐Scherrer
Robin Pourzal
Peter Wahl
collection Wiley Open Access
contents Fourier‐transform infrared spectroscopy imaging is a useful adjunct to routine histopathology to identify failure of polyethylene inlays in revision total hip arthroplasty Songyun Liu Deborah J. Hall Corina Dommann‐Scherrer Robin Pourzal Peter Wahl APMIS The use of highly crosslinked ultra‐high molecular weight polyethylene (XLPE) has significantly reduced the volumetric wear of acetabular liners, thereby reducing the incidence of osteolysis. However, contemporary components tend to generate smaller wear particles, which can no longer be identified using conventional histology. This technical limitation can result in imprecise diagnosis. Here, we report on two uncemented total hip arthroplasty cases (~7 years in situ) revised for periprosthetic fracture of the femur and femoral loosening, respectively. Both liners exhibited prominent wear. The retrieved pseudocapsular tissue exhibited a strong macrophage infiltration without microscopically identifiable polyethylene particles. Yet, using Fourier‐transform infrared micro‐spectroscopic imaging (FTIR‐I), we demonstrated the prominent intracellular accumulation of polyethylene debris in both cases. This study shows that particle induced osteolysis can still occur with XLPE liners, even under 10 years in situ. Furthermore, we demonstrate the difficulty of determining the presence of polyethylene debris within periprosthetic tissue. Considering the potentially increased bioactivity of finer particles from XLPE compared to conventional liners, an accurate detection method is required, and new histopathological hallmarks of particle induced osteolysis are needed. FTIR‐I is a great tool to that end and can help the accurate determination of foreign body tissue responses. 10.1111/apm.13421 http://creativecommons.org/licenses/by-nc/4.0/
doi_str_mv 10.1111/apm.13421
format Artículo Open Access
id wiley_oa_10_1111_apm_13421
institution Wiley Open Access
license_str_mv http://creativecommons.org/licenses/by-nc/4.0/
publishDate 2024
publisher Wiley
record_format wiley_oa
spellingShingle Fourier‐transform infrared spectroscopy imaging is a useful adjunct to routine histopathology to identify failure of polyethylene inlays in revision total hip arthroplasty
Songyun Liu
Deborah J. Hall
Corina Dommann‐Scherrer
Robin Pourzal
Peter Wahl
APMIS
Fourier‐transform infrared spectroscopy imaging is a useful adjunct to routine histopathology to identify failure of polyethylene inlays in revision total hip arthroplasty Songyun Liu Deborah J. Hall Corina Dommann‐Scherrer Robin Pourzal Peter Wahl APMIS The use of highly crosslinked ultra‐high molecular weight polyethylene (XLPE) has significantly reduced the volumetric wear of acetabular liners, thereby reducing the incidence of osteolysis. However, contemporary components tend to generate smaller wear particles, which can no longer be identified using conventional histology. This technical limitation can result in imprecise diagnosis. Here, we report on two uncemented total hip arthroplasty cases (~7 years in situ) revised for periprosthetic fracture of the femur and femoral loosening, respectively. Both liners exhibited prominent wear. The retrieved pseudocapsular tissue exhibited a strong macrophage infiltration without microscopically identifiable polyethylene particles. Yet, using Fourier‐transform infrared micro‐spectroscopic imaging (FTIR‐I), we demonstrated the prominent intracellular accumulation of polyethylene debris in both cases. This study shows that particle induced osteolysis can still occur with XLPE liners, even under 10 years in situ. Furthermore, we demonstrate the difficulty of determining the presence of polyethylene debris within periprosthetic tissue. Considering the potentially increased bioactivity of finer particles from XLPE compared to conventional liners, an accurate detection method is required, and new histopathological hallmarks of particle induced osteolysis are needed. FTIR‐I is a great tool to that end and can help the accurate determination of foreign body tissue responses. 10.1111/apm.13421 http://creativecommons.org/licenses/by-nc/4.0/
title Fourier‐transform infrared spectroscopy imaging is a useful adjunct to routine histopathology to identify failure of polyethylene inlays in revision total hip arthroplasty
topic APMIS
url https://onlinelibrary.wiley.com/doi/10.1111/apm.13421