Saved in:
Bibliographic Details
Main Authors: K. Piontek, S. Radonjic‐Hoesli, J. Grabbe, K. P. Drewitz, C. Apfelbacher, S. Wöhrl, D. Simon, C. Lang, S. Schubert
Format: Artículo Open Access
Published: Wiley 2024
Subjects:
Online Access:https://onlinelibrary.wiley.com/doi/10.1111/cod.14701
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1867015354854670337
author K. Piontek
S. Radonjic‐Hoesli
J. Grabbe
K. P. Drewitz
C. Apfelbacher
S. Wöhrl
D. Simon
C. Lang
S. Schubert
author_facet K. Piontek
S. Radonjic‐Hoesli
J. Grabbe
K. P. Drewitz
C. Apfelbacher
S. Wöhrl
D. Simon
C. Lang
S. Schubert
K. Piontek
S. Radonjic‐Hoesli
J. Grabbe
K. P. Drewitz
C. Apfelbacher
S. Wöhrl
D. Simon
C. Lang
S. Schubert
collection Wiley Open Access
contents Comparison of patch testing Brazilian (Green) propolis and Chinese (poplar‐type) propolis: Clinical epidemiological study using data from the Information Network of Departments of Dermatology (IVDK) K. Piontek S. Radonjic‐Hoesli J. Grabbe K. P. Drewitz C. Apfelbacher S. Wöhrl D. Simon C. Lang S. Schubert Contact Dermatitis AbstractBackgroundPropolis types differ regarding their chemical composition.ObjectivesTo compare patch test results based on Brazilian (Green) propolis with data based on Chinese (poplar‐type) propolis, and to evaluate the specifications of raw materials used for the PT preparations.MethodsIn the Information Network of Departments of Dermatology (IVDK), 1290 consecutive patients were patch tested with Brazilian (Green) propolis (NH400, SmartPractice Europe). Patch test reactivity was compared with results obtained with Chinese (poplar‐type) propolis (NA71, SmartPractice Europe) by calculating frequencies and corresponding 95% confidence intervals. Data on the specifications of raw materials used for NH400 and NA71 were obtained from the manufacturer.ResultsPositive reactions to NH400 were found in 303 (23.5%) patients with unclear clinical relevance in most cases. Patients reacting to NH400 were less often sensitised to fragrances and colophony, but more often to nickel sulphate and cobalt chloride than patients reacting to NA71. The NH400 batch used contained high levels of aerobic bacteria, and was not purified by ethanolic extraction.ConclusionsPattern of concomitant reactivity along with raw material properties suggests that the high frequency of positive reactions to NH400 may primarily result from bacterial contamination or impurities in the PT preparation rather than from propolis constituents. 10.1111/cod.14701 http://onlinelibrary.wiley.com/termsAndConditions#vor
doi_str_mv 10.1111/cod.14701
format Artículo Open Access
id wiley_oa_10_1111_cod_14701
institution Wiley Open Access
license_str_mv http://onlinelibrary.wiley.com/termsAndConditions#vor
publishDate 2024
publisher Wiley
record_format wiley_oa
spellingShingle Comparison of patch testing Brazilian (Green) propolis and Chinese (poplar‐type) propolis: Clinical epidemiological study using data from the Information Network of Departments of Dermatology (IVDK)
K. Piontek
S. Radonjic‐Hoesli
J. Grabbe
K. P. Drewitz
C. Apfelbacher
S. Wöhrl
D. Simon
C. Lang
S. Schubert
Contact Dermatitis
Comparison of patch testing Brazilian (Green) propolis and Chinese (poplar‐type) propolis: Clinical epidemiological study using data from the Information Network of Departments of Dermatology (IVDK) K. Piontek S. Radonjic‐Hoesli J. Grabbe K. P. Drewitz C. Apfelbacher S. Wöhrl D. Simon C. Lang S. Schubert Contact Dermatitis AbstractBackgroundPropolis types differ regarding their chemical composition.ObjectivesTo compare patch test results based on Brazilian (Green) propolis with data based on Chinese (poplar‐type) propolis, and to evaluate the specifications of raw materials used for the PT preparations.MethodsIn the Information Network of Departments of Dermatology (IVDK), 1290 consecutive patients were patch tested with Brazilian (Green) propolis (NH400, SmartPractice Europe). Patch test reactivity was compared with results obtained with Chinese (poplar‐type) propolis (NA71, SmartPractice Europe) by calculating frequencies and corresponding 95% confidence intervals. Data on the specifications of raw materials used for NH400 and NA71 were obtained from the manufacturer.ResultsPositive reactions to NH400 were found in 303 (23.5%) patients with unclear clinical relevance in most cases. Patients reacting to NH400 were less often sensitised to fragrances and colophony, but more often to nickel sulphate and cobalt chloride than patients reacting to NA71. The NH400 batch used contained high levels of aerobic bacteria, and was not purified by ethanolic extraction.ConclusionsPattern of concomitant reactivity along with raw material properties suggests that the high frequency of positive reactions to NH400 may primarily result from bacterial contamination or impurities in the PT preparation rather than from propolis constituents. 10.1111/cod.14701 http://onlinelibrary.wiley.com/termsAndConditions#vor
title Comparison of patch testing Brazilian (Green) propolis and Chinese (poplar‐type) propolis: Clinical epidemiological study using data from the Information Network of Departments of Dermatology (IVDK)
topic Contact Dermatitis
url https://onlinelibrary.wiley.com/doi/10.1111/cod.14701