1,6‐Hexanediol Diacrylate, Isocyanates and Other Skin Sensitizers Are Emerging Contact Allergens in Guardian Glucose Sensors

Fuente: Wiley Open Access
Salvato in:
Dettagli Bibliografici
Autori principali: Ella Dendooven, Fleur Haentjens, Silada Kanokrungsee, Tania Naessens, Emmy Tuenter, Kenn Foubert, Nina Hermans, Eveline Dirinck, Christophe De Block, Olivier Aerts
Natura: Artículo Open Access
Pubblicazione: Wiley 2025
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1867013592309563392
author Ella Dendooven
Fleur Haentjens
Silada Kanokrungsee
Tania Naessens
Emmy Tuenter
Kenn Foubert
Nina Hermans
Eveline Dirinck
Christophe De Block
Olivier Aerts
author_facet Ella Dendooven
Fleur Haentjens
Silada Kanokrungsee
Tania Naessens
Emmy Tuenter
Kenn Foubert
Nina Hermans
Eveline Dirinck
Christophe De Block
Olivier Aerts
Ella Dendooven
Fleur Haentjens
Silada Kanokrungsee
Tania Naessens
Emmy Tuenter
Kenn Foubert
Nina Hermans
Eveline Dirinck
Christophe De Block
Olivier Aerts
collection Wiley Open Access
contents 1,6‐Hexanediol Diacrylate, Isocyanates and Other Skin Sensitizers Are Emerging Contact Allergens in Guardian Glucose Sensors Ella Dendooven Fleur Haentjens Silada Kanokrungsee Tania Naessens Emmy Tuenter Kenn Foubert Nina Hermans Eveline Dirinck Christophe De Block Olivier Aerts Contact Dermatitis ABSTRACT Background Allergic contact dermatitis (ACD) from diabetes devices remains a significant concern. Objective To report ACD from Guardian 3 and 4 glucose sensors (G3/4 sensors) due to multiple skin sensitizers, that is, isobornyl acrylate (IBOA), N,N ‐dimethylacrylamide (DMAA) and also 1,6‐hexanediol diacrylate (HDDA), isocyanates, colophonium derivatives, tert‐butylphenols (TBPs) and salicylates. Methods Twenty‐seven patients with ACD from G3/4 sensors, evaluated between January 2020 and December 2024, were patch‐tested to a baseline, acrylate, isocyanate and plastics and glue series. The sensors and their overtape (Oval Tape) were analysed with gas chromatography–mass spectrometry (GC‐MS). Results Most patients (44%) reacted to colophonium (derivatives), followed by IBOA (31%) and isocyanates (29%). Fewer, yet remarkable reactions were observed to HDDA (20%), TBPs (12.5%) and DMAA (8%). All IBOA and DMAA‐allergic patients had been previously sensitised by the FreeStyle I sensor, whereas patients using G3/4 sensors as their first diabetes device were not sensitised to these two allergens. Chemical analyses confirmed the presence of colophonium derivatives, IBOA, DMAA, HDDA, isocyanates, TBPs and, interestingly, also salicylates, as skin sensitizers in these sensors. Conclusions The newer glucose sensors Guardian 3 and 4 contain, besides IBOA and DMAA, also HDDA, together with a multitude of other skin sensitizers that put patients at risk of developing ACD. 10.1111/cod.70010 http://onlinelibrary.wiley.com/termsAndConditions#vor
doi_str_mv 10.1111/cod.70010
format Artículo Open Access
id wiley_oa_10_1111_cod_70010
institution Wiley Open Access
license_str_mv http://onlinelibrary.wiley.com/termsAndConditions#vor
publishDate 2025
publisher Wiley
record_format wiley_oa
spellingShingle 1,6‐Hexanediol Diacrylate, Isocyanates and Other Skin Sensitizers Are Emerging Contact Allergens in Guardian Glucose Sensors
Ella Dendooven
Fleur Haentjens
Silada Kanokrungsee
Tania Naessens
Emmy Tuenter
Kenn Foubert
Nina Hermans
Eveline Dirinck
Christophe De Block
Olivier Aerts
Contact Dermatitis
1,6‐Hexanediol Diacrylate, Isocyanates and Other Skin Sensitizers Are Emerging Contact Allergens in Guardian Glucose Sensors Ella Dendooven Fleur Haentjens Silada Kanokrungsee Tania Naessens Emmy Tuenter Kenn Foubert Nina Hermans Eveline Dirinck Christophe De Block Olivier Aerts Contact Dermatitis ABSTRACT Background Allergic contact dermatitis (ACD) from diabetes devices remains a significant concern. Objective To report ACD from Guardian 3 and 4 glucose sensors (G3/4 sensors) due to multiple skin sensitizers, that is, isobornyl acrylate (IBOA), N,N ‐dimethylacrylamide (DMAA) and also 1,6‐hexanediol diacrylate (HDDA), isocyanates, colophonium derivatives, tert‐butylphenols (TBPs) and salicylates. Methods Twenty‐seven patients with ACD from G3/4 sensors, evaluated between January 2020 and December 2024, were patch‐tested to a baseline, acrylate, isocyanate and plastics and glue series. The sensors and their overtape (Oval Tape) were analysed with gas chromatography–mass spectrometry (GC‐MS). Results Most patients (44%) reacted to colophonium (derivatives), followed by IBOA (31%) and isocyanates (29%). Fewer, yet remarkable reactions were observed to HDDA (20%), TBPs (12.5%) and DMAA (8%). All IBOA and DMAA‐allergic patients had been previously sensitised by the FreeStyle I sensor, whereas patients using G3/4 sensors as their first diabetes device were not sensitised to these two allergens. Chemical analyses confirmed the presence of colophonium derivatives, IBOA, DMAA, HDDA, isocyanates, TBPs and, interestingly, also salicylates, as skin sensitizers in these sensors. Conclusions The newer glucose sensors Guardian 3 and 4 contain, besides IBOA and DMAA, also HDDA, together with a multitude of other skin sensitizers that put patients at risk of developing ACD. 10.1111/cod.70010 http://onlinelibrary.wiley.com/termsAndConditions#vor
title 1,6‐Hexanediol Diacrylate, Isocyanates and Other Skin Sensitizers Are Emerging Contact Allergens in Guardian Glucose Sensors
topic Contact Dermatitis
url https://onlinelibrary.wiley.com/doi/10.1111/cod.70010