Allergic Contact Dermatitis From Medical Adhesive Tape Used for Friction Blister Prevention in the Norwegian Armed Forces: A Case Series

Fuente: Wiley Open Access
Salvato in:
Dettagli Bibliografici
Autori principali: Anna Beathe Overn Nordhammer, Jakob Willner, Cecilia Svedman, Jakob Dahlin, Toril Synnøve Nilsen, Liv Bjerke Rodal, Jan Ulrik Opstad Sinding, Marit Saunes, Kristin Hjelmeland, Erlend Hassel
Natura: Artículo Open Access
Pubblicazione: Wiley 2026
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1867019003236450305
author Anna Beathe Overn Nordhammer
Jakob Willner
Cecilia Svedman
Jakob Dahlin
Toril Synnøve Nilsen
Liv Bjerke Rodal
Jan Ulrik Opstad Sinding
Marit Saunes
Kristin Hjelmeland
Erlend Hassel
author_facet Anna Beathe Overn Nordhammer
Jakob Willner
Cecilia Svedman
Jakob Dahlin
Toril Synnøve Nilsen
Liv Bjerke Rodal
Jan Ulrik Opstad Sinding
Marit Saunes
Kristin Hjelmeland
Erlend Hassel
Anna Beathe Overn Nordhammer
Jakob Willner
Cecilia Svedman
Jakob Dahlin
Toril Synnøve Nilsen
Liv Bjerke Rodal
Jan Ulrik Opstad Sinding
Marit Saunes
Kristin Hjelmeland
Erlend Hassel
collection Wiley Open Access
contents Allergic Contact Dermatitis From Medical Adhesive Tape Used for Friction Blister Prevention in the Norwegian Armed Forces: A Case Series Anna Beathe Overn Nordhammer Jakob Willner Cecilia Svedman Jakob Dahlin Toril Synnøve Nilsen Liv Bjerke Rodal Jan Ulrik Opstad Sinding Marit Saunes Kristin Hjelmeland Erlend Hassel Contact Dermatitis ABSTRACT Background Colophony and its derivatives are common allergens. Contact dermatitis from colophony‐containing adhesive tapes for blister prevention has previously been reported among Swedish conscripts. Objectives To present the investigation of suspected allergic contact dermatitis among Norwegian military personnel exposed to medical adhesive tapes during service. Patients/Materials/Methods Fourteen conscripts and military personnel were examined at St. Olavs Hospital. Aimed patch testing was conducted, and chemical analysis of medical adhesive tapes was performed. All patients received occupational medical consultation and exposure avoidance advice. Results Thirteen patients were diagnosed with allergic contact dermatitis, with positive patch tests to colophony and modified colophony and the medical adhesive tape used during service. Most patients exhibited strong sensitisation to colophony, reacting to very low concentrations. The majority were women, and many had simultaneous sensitisation to fragrance allergens. All patients were advised that their condition was work‐related, with potential implications for future careers. Conclusions Use of colophony‐containing medical adhesive tapes in the Norwegian Armed Forces has caused strong allergies among our patients, with potential long‐term occupational and health consequences. Alternative blister prevention measures such as improved footwear and increased transparency and information regarding the chemical composition of medical devices are recommended. 10.1111/cod.70144 http://onlinelibrary.wiley.com/termsAndConditions#vor
doi_str_mv 10.1111/cod.70144
format Artículo Open Access
id wiley_oa_10_1111_cod_70144
institution Wiley Open Access
license_str_mv http://onlinelibrary.wiley.com/termsAndConditions#vor
publishDate 2026
publisher Wiley
record_format wiley_oa
spellingShingle Allergic Contact Dermatitis From Medical Adhesive Tape Used for Friction Blister Prevention in the Norwegian Armed Forces: A Case Series
Anna Beathe Overn Nordhammer
Jakob Willner
Cecilia Svedman
Jakob Dahlin
Toril Synnøve Nilsen
Liv Bjerke Rodal
Jan Ulrik Opstad Sinding
Marit Saunes
Kristin Hjelmeland
Erlend Hassel
Contact Dermatitis
Allergic Contact Dermatitis From Medical Adhesive Tape Used for Friction Blister Prevention in the Norwegian Armed Forces: A Case Series Anna Beathe Overn Nordhammer Jakob Willner Cecilia Svedman Jakob Dahlin Toril Synnøve Nilsen Liv Bjerke Rodal Jan Ulrik Opstad Sinding Marit Saunes Kristin Hjelmeland Erlend Hassel Contact Dermatitis ABSTRACT Background Colophony and its derivatives are common allergens. Contact dermatitis from colophony‐containing adhesive tapes for blister prevention has previously been reported among Swedish conscripts. Objectives To present the investigation of suspected allergic contact dermatitis among Norwegian military personnel exposed to medical adhesive tapes during service. Patients/Materials/Methods Fourteen conscripts and military personnel were examined at St. Olavs Hospital. Aimed patch testing was conducted, and chemical analysis of medical adhesive tapes was performed. All patients received occupational medical consultation and exposure avoidance advice. Results Thirteen patients were diagnosed with allergic contact dermatitis, with positive patch tests to colophony and modified colophony and the medical adhesive tape used during service. Most patients exhibited strong sensitisation to colophony, reacting to very low concentrations. The majority were women, and many had simultaneous sensitisation to fragrance allergens. All patients were advised that their condition was work‐related, with potential implications for future careers. Conclusions Use of colophony‐containing medical adhesive tapes in the Norwegian Armed Forces has caused strong allergies among our patients, with potential long‐term occupational and health consequences. Alternative blister prevention measures such as improved footwear and increased transparency and information regarding the chemical composition of medical devices are recommended. 10.1111/cod.70144 http://onlinelibrary.wiley.com/termsAndConditions#vor
title Allergic Contact Dermatitis From Medical Adhesive Tape Used for Friction Blister Prevention in the Norwegian Armed Forces: A Case Series
topic Contact Dermatitis
url https://onlinelibrary.wiley.com/doi/10.1111/cod.70144