International expert consensus on a structured approach to robotic multiport right hemicolectomy with complete mesocolic excision and intracorporeal anastomosis

Fuente: Wiley Open Access
Guardado en:
Detalles Bibliográficos
Autores principales: Marcos Gómez Ruiz, Paolo Pietro Bianchi, Roland Croner, Samson Tou, Klaus Matzel, Anthony G. Gallagher
Formato: Artículo Open Access
Publicado: Wiley 2025
Materias:
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1867015556526243840
author Marcos Gómez Ruiz
Paolo Pietro Bianchi
Roland Croner
Samson Tou
Klaus Matzel
Anthony G. Gallagher
author_facet Marcos Gómez Ruiz
Paolo Pietro Bianchi
Roland Croner
Samson Tou
Klaus Matzel
Anthony G. Gallagher
Marcos Gómez Ruiz
Paolo Pietro Bianchi
Roland Croner
Samson Tou
Klaus Matzel
Anthony G. Gallagher
collection Wiley Open Access
contents International expert consensus on a structured approach to robotic multiport right hemicolectomy with complete mesocolic excision and intracorporeal anastomosis Marcos Gómez Ruiz Paolo Pietro Bianchi Roland Croner Samson Tou Klaus Matzel Anthony G. Gallagher Colorectal Disease Abstract Aim To develop and operationally define ‘performance metrics’ that characterize a reference approach to robotic multiport right hemicolectomy with complete mesocolic excision (CME) and intracorporeal anastomosis (ICA) and to obtain evidence supporting face and content validity through a consensus meeting. Method Three expert colorectal surgeons with advanced minimally invasive surgical experience, a senior behavioural scientist and a colorectal surgeon with experience in performance metrics development formed the Metrics Group. Published guidelines, clinical evidence, training materials and unedited videos of robotic multiport right hemicolectomy were used to deconstruct the task—robotic right hemicolectomy with CME and ICA—into defined, observable performance units or metrics (i.e. procedure Phases, Steps, Errors and Critical Errors). The performance metrics were then subjected to detailed review by nine expert colorectal surgeons in a modified Delphi process. Results Performance metrics for robotic multiport right hemicolectomy with CME and ICA were deconstructed and described as 15 procedure phases with 124 steps, all of them associated with 146 errors and 136 critical errors. After the modified Delphi process, the agreed performance metrics consisted of 15 procedure phases and 125 steps, 150 errors and 139 critical errors. After discussion, agreed modifications to the metrics an international group of expert colorectal surgeons reached 100% consensus on them, thus providing evidence to support the face and content validity of the metrics. Conclusion Robotic multiport right hemicolectomy with CME and ICA can be broken down into explicitly defined procedure phases and steps, with errors and critical errors known as performance metrics. We consider the metrics imperative for the development of a safe and structured training in robotic multiport right hemicolectomy with CME and ICA. 10.1111/codi.70197 http://creativecommons.org/licenses/by/4.0/
doi_str_mv 10.1111/codi.70197
format Artículo Open Access
id wiley_oa_10_1111_codi_70197
institution Wiley Open Access
license_str_mv http://creativecommons.org/licenses/by/4.0/
publishDate 2025
publisher Wiley
record_format wiley_oa
spellingShingle International expert consensus on a structured approach to robotic multiport right hemicolectomy with complete mesocolic excision and intracorporeal anastomosis
Marcos Gómez Ruiz
Paolo Pietro Bianchi
Roland Croner
Samson Tou
Klaus Matzel
Anthony G. Gallagher
Colorectal Disease
International expert consensus on a structured approach to robotic multiport right hemicolectomy with complete mesocolic excision and intracorporeal anastomosis Marcos Gómez Ruiz Paolo Pietro Bianchi Roland Croner Samson Tou Klaus Matzel Anthony G. Gallagher Colorectal Disease Abstract Aim To develop and operationally define ‘performance metrics’ that characterize a reference approach to robotic multiport right hemicolectomy with complete mesocolic excision (CME) and intracorporeal anastomosis (ICA) and to obtain evidence supporting face and content validity through a consensus meeting. Method Three expert colorectal surgeons with advanced minimally invasive surgical experience, a senior behavioural scientist and a colorectal surgeon with experience in performance metrics development formed the Metrics Group. Published guidelines, clinical evidence, training materials and unedited videos of robotic multiport right hemicolectomy were used to deconstruct the task—robotic right hemicolectomy with CME and ICA—into defined, observable performance units or metrics (i.e. procedure Phases, Steps, Errors and Critical Errors). The performance metrics were then subjected to detailed review by nine expert colorectal surgeons in a modified Delphi process. Results Performance metrics for robotic multiport right hemicolectomy with CME and ICA were deconstructed and described as 15 procedure phases with 124 steps, all of them associated with 146 errors and 136 critical errors. After the modified Delphi process, the agreed performance metrics consisted of 15 procedure phases and 125 steps, 150 errors and 139 critical errors. After discussion, agreed modifications to the metrics an international group of expert colorectal surgeons reached 100% consensus on them, thus providing evidence to support the face and content validity of the metrics. Conclusion Robotic multiport right hemicolectomy with CME and ICA can be broken down into explicitly defined procedure phases and steps, with errors and critical errors known as performance metrics. We consider the metrics imperative for the development of a safe and structured training in robotic multiport right hemicolectomy with CME and ICA. 10.1111/codi.70197 http://creativecommons.org/licenses/by/4.0/
title International expert consensus on a structured approach to robotic multiport right hemicolectomy with complete mesocolic excision and intracorporeal anastomosis
topic Colorectal Disease
url https://onlinelibrary.wiley.com/doi/10.1111/codi.70197