Normothermic Perfusion Versus Static Cold Storage in Liver Transplantation: A Meta‐Analysis of Randomized Trials

Fuente: Wiley Open Access
Salvato in:
Dettagli Bibliografici
Autori principali: Heithem Jeddou, Stylianos Tzedakis, Hector Prudhomme, Aline Wautier, Corentin Sumner, Eya Ben Nejma, Mohamad Ali Zorkot, Raffaele Vincenzo De Rosa, Gennaro Mazzarella, Mohamed Ali Chaouch, Michel Samson, Karim Boudjema
Natura: Artículo Open Access
Pubblicazione: Wiley 2025
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1867011508436729856
author Heithem Jeddou
Stylianos Tzedakis
Hector Prudhomme
Aline Wautier
Corentin Sumner
Eya Ben Nejma
Mohamad Ali Zorkot
Raffaele Vincenzo De Rosa
Gennaro Mazzarella
Mohamed Ali Chaouch
Michel Samson
Karim Boudjema
author_facet Heithem Jeddou
Stylianos Tzedakis
Hector Prudhomme
Aline Wautier
Corentin Sumner
Eya Ben Nejma
Mohamad Ali Zorkot
Raffaele Vincenzo De Rosa
Gennaro Mazzarella
Mohamed Ali Chaouch
Michel Samson
Karim Boudjema
Heithem Jeddou
Stylianos Tzedakis
Hector Prudhomme
Aline Wautier
Corentin Sumner
Eya Ben Nejma
Mohamad Ali Zorkot
Raffaele Vincenzo De Rosa
Gennaro Mazzarella
Mohamed Ali Chaouch
Michel Samson
Karim Boudjema
collection Wiley Open Access
contents Normothermic Perfusion Versus Static Cold Storage in Liver Transplantation: A Meta‐Analysis of Randomized Trials Heithem Jeddou Stylianos Tzedakis Hector Prudhomme Aline Wautier Corentin Sumner Eya Ben Nejma Mohamad Ali Zorkot Raffaele Vincenzo De Rosa Gennaro Mazzarella Mohamed Ali Chaouch Michel Samson Karim Boudjema Clinical Transplantation ABSTRACT Background Normothermic machine perfusion (NMP) is an alternative to static cold storage (SCS) for liver graft preservation, potentially reducing ischemia–reperfusion injury and improving organ utilization. Methods We systematically reviewed RCTs comparing end‐ischemic NMP with SCS in adult liver transplantation (MEDLINE, EMBASE, CENTRAL to July 9, 2025). Outcomes of interest included early allograft dysfunction (EAD), organ utilization, patient and graft survival, peak AST, primary non‐function (PNF), and biliary complications. Results Four RCTs (801 patients; NMP 418; SCS 383) met inclusion. NMP reduced EAD [16.4% vs. 27.2%; RR 0.61, 95% confidence interval (95% CI) 0.38–0.99; p = 0.05] and increased organ utilization (75.5% vs. 69.4%; RR 1.10, 95% CI 1.02–1.18; p = 0.01). No significant differences were observed for patient or graft survival, peak AST, PNF, or biliary complications, though the latter trended in favor of NMP (RR 0.73, p = 0.07). Conclusion In adult liver transplantation, NMP reduces EAD and improves organ utilization compared with SCS, without significant differences in survival or major postoperative complications. Evidence remains limited to few trials; larger RCTs are needed to assess long‐term benefits. 10.1111/ctr.70372 http://creativecommons.org/licenses/by-nc/4.0/
doi_str_mv 10.1111/ctr.70372
format Artículo Open Access
id wiley_oa_10_1111_ctr_70372
institution Wiley Open Access
license_str_mv http://creativecommons.org/licenses/by-nc/4.0/
publishDate 2025
publisher Wiley
record_format wiley_oa
spellingShingle Normothermic Perfusion Versus Static Cold Storage in Liver Transplantation: A Meta‐Analysis of Randomized Trials
Heithem Jeddou
Stylianos Tzedakis
Hector Prudhomme
Aline Wautier
Corentin Sumner
Eya Ben Nejma
Mohamad Ali Zorkot
Raffaele Vincenzo De Rosa
Gennaro Mazzarella
Mohamed Ali Chaouch
Michel Samson
Karim Boudjema
Clinical Transplantation
Normothermic Perfusion Versus Static Cold Storage in Liver Transplantation: A Meta‐Analysis of Randomized Trials Heithem Jeddou Stylianos Tzedakis Hector Prudhomme Aline Wautier Corentin Sumner Eya Ben Nejma Mohamad Ali Zorkot Raffaele Vincenzo De Rosa Gennaro Mazzarella Mohamed Ali Chaouch Michel Samson Karim Boudjema Clinical Transplantation ABSTRACT Background Normothermic machine perfusion (NMP) is an alternative to static cold storage (SCS) for liver graft preservation, potentially reducing ischemia–reperfusion injury and improving organ utilization. Methods We systematically reviewed RCTs comparing end‐ischemic NMP with SCS in adult liver transplantation (MEDLINE, EMBASE, CENTRAL to July 9, 2025). Outcomes of interest included early allograft dysfunction (EAD), organ utilization, patient and graft survival, peak AST, primary non‐function (PNF), and biliary complications. Results Four RCTs (801 patients; NMP 418; SCS 383) met inclusion. NMP reduced EAD [16.4% vs. 27.2%; RR 0.61, 95% confidence interval (95% CI) 0.38–0.99; p = 0.05] and increased organ utilization (75.5% vs. 69.4%; RR 1.10, 95% CI 1.02–1.18; p = 0.01). No significant differences were observed for patient or graft survival, peak AST, PNF, or biliary complications, though the latter trended in favor of NMP (RR 0.73, p = 0.07). Conclusion In adult liver transplantation, NMP reduces EAD and improves organ utilization compared with SCS, without significant differences in survival or major postoperative complications. Evidence remains limited to few trials; larger RCTs are needed to assess long‐term benefits. 10.1111/ctr.70372 http://creativecommons.org/licenses/by-nc/4.0/
title Normothermic Perfusion Versus Static Cold Storage in Liver Transplantation: A Meta‐Analysis of Randomized Trials
topic Clinical Transplantation
url https://onlinelibrary.wiley.com/doi/10.1111/ctr.70372