Salvato in:
Dettagli Bibliografici
Autori principali: Fuat Polat, Zeynettin Kaya, Barış Yaylak, Tolga Onuk
Natura: Artículo Open Access
Pubblicazione: Wiley 2024
Soggetti:
Accesso online:https://onlinelibrary.wiley.com/doi/10.1111/echo.15770
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1867013272849350656
author Fuat Polat
Zeynettin Kaya
Barış Yaylak
Tolga Onuk
author_facet Fuat Polat
Zeynettin Kaya
Barış Yaylak
Tolga Onuk
Fuat Polat
Zeynettin Kaya
Barış Yaylak
Tolga Onuk
collection Wiley Open Access
contents Comparison of echocardiographic and clinical characteristics in embolic stroke and migraine patients with patent foramen ovale Fuat Polat Zeynettin Kaya Barış Yaylak Tolga Onuk Echocardiography AbstractBackgroundThis single‐center observational study aimed to compare the echocardiographic and clinical features in patients diagnosed with migraine and embolic stroke of undetermined source (ESUS) who presented with a known patent foramen ovale (PFO).MethodsTwo‐dimensional and color Doppler images were obtained using various transthoracic echocardiography views for both migraine and ESUS patients. Suspected PFO cases underwent further assessment through contrast echocardiography and transesophageal echocardiography (TEE). High‐risk PFO characteristics were evaluated using TEE, and the Risk of Paradoxical Embolism (RoPe) score was calculated.ResultsThe study included 310 participants (age range: 18–60, 73.2% female), with 43.5% diagnosed with migraine and 56.5% with ESUS. Common comorbidities included diabetes (26.1%). High‐velocity shunting through the interatrial septum was observed in 35.5% of patients. ESUS patients were older, with higher rates of diabetes and hypertension, while active smoking was more prevalent among migraine patients. Basic echocardiographic parameters were mostly similar, except for elevated pulmonary artery systolic pressure in ESUS. ESUS patients exhibited a greater occurrence of large microbubble passage through the interatrial septum and longer PFO lengths compared to migraine patients. However, the RoPe and High‐risk PFO scores were similar between the groups.ConclusionsESUS patients, characterized by older age and higher rates of diabetes and hypertension, demonstrated increased pulmonary artery pressure, more significant microbubble crossings, and longer PFO lengths. Conversely, migraine patients had a higher prevalence of active smoking. Despite differing clinical profiles, the risk scores for PFO‐related embolic events were comparable between the groups. These findings underscore potential distinctions between ESUS and migraine patients with PFO and their implications for management strategies. 10.1111/echo.15770 http://onlinelibrary.wiley.com/termsAndConditions#vor
doi_str_mv 10.1111/echo.15770
format Artículo Open Access
id wiley_oa_10_1111_echo_15770
institution Wiley Open Access
license_str_mv http://onlinelibrary.wiley.com/termsAndConditions#vor
publishDate 2024
publisher Wiley
record_format wiley_oa
spellingShingle Comparison of echocardiographic and clinical characteristics in embolic stroke and migraine patients with patent foramen ovale
Fuat Polat
Zeynettin Kaya
Barış Yaylak
Tolga Onuk
Echocardiography
Comparison of echocardiographic and clinical characteristics in embolic stroke and migraine patients with patent foramen ovale Fuat Polat Zeynettin Kaya Barış Yaylak Tolga Onuk Echocardiography AbstractBackgroundThis single‐center observational study aimed to compare the echocardiographic and clinical features in patients diagnosed with migraine and embolic stroke of undetermined source (ESUS) who presented with a known patent foramen ovale (PFO).MethodsTwo‐dimensional and color Doppler images were obtained using various transthoracic echocardiography views for both migraine and ESUS patients. Suspected PFO cases underwent further assessment through contrast echocardiography and transesophageal echocardiography (TEE). High‐risk PFO characteristics were evaluated using TEE, and the Risk of Paradoxical Embolism (RoPe) score was calculated.ResultsThe study included 310 participants (age range: 18–60, 73.2% female), with 43.5% diagnosed with migraine and 56.5% with ESUS. Common comorbidities included diabetes (26.1%). High‐velocity shunting through the interatrial septum was observed in 35.5% of patients. ESUS patients were older, with higher rates of diabetes and hypertension, while active smoking was more prevalent among migraine patients. Basic echocardiographic parameters were mostly similar, except for elevated pulmonary artery systolic pressure in ESUS. ESUS patients exhibited a greater occurrence of large microbubble passage through the interatrial septum and longer PFO lengths compared to migraine patients. However, the RoPe and High‐risk PFO scores were similar between the groups.ConclusionsESUS patients, characterized by older age and higher rates of diabetes and hypertension, demonstrated increased pulmonary artery pressure, more significant microbubble crossings, and longer PFO lengths. Conversely, migraine patients had a higher prevalence of active smoking. Despite differing clinical profiles, the risk scores for PFO‐related embolic events were comparable between the groups. These findings underscore potential distinctions between ESUS and migraine patients with PFO and their implications for management strategies. 10.1111/echo.15770 http://onlinelibrary.wiley.com/termsAndConditions#vor
title Comparison of echocardiographic and clinical characteristics in embolic stroke and migraine patients with patent foramen ovale
topic Echocardiography
url https://onlinelibrary.wiley.com/doi/10.1111/echo.15770