Study of Degenerative Mitral Regurgitation Using Three‐Dimensional Echocardiography and EchoPAC GE Health Care Software 4D Auto MVQ: Comparison Between Transthoracic and Transesophageal Examination

Fuente: Wiley Open Access
Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Ginevra Fioretti, Alice Tolomei, Piera Ciaramella, Antonio Lio, Ernesto Cristiano, Giulio Cacioli, Federica Tempestini, Federico Ranocchi, Viviana Maestrini, Amedeo Pergolini
Format: Artículo Open Access
Veröffentlicht: Wiley 2024
Schlagworte:
Online-Zugang:
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
_version_ 1867007807432163328
author Ginevra Fioretti
Alice Tolomei
Piera Ciaramella
Antonio Lio
Ernesto Cristiano
Giulio Cacioli
Federica Tempestini
Federico Ranocchi
Viviana Maestrini
Amedeo Pergolini
author_facet Ginevra Fioretti
Alice Tolomei
Piera Ciaramella
Antonio Lio
Ernesto Cristiano
Giulio Cacioli
Federica Tempestini
Federico Ranocchi
Viviana Maestrini
Amedeo Pergolini
Ginevra Fioretti
Alice Tolomei
Piera Ciaramella
Antonio Lio
Ernesto Cristiano
Giulio Cacioli
Federica Tempestini
Federico Ranocchi
Viviana Maestrini
Amedeo Pergolini
collection Wiley Open Access
contents Study of Degenerative Mitral Regurgitation Using Three‐Dimensional Echocardiography and EchoPAC GE Health Care Software 4D Auto MVQ: Comparison Between Transthoracic and Transesophageal Examination Ginevra Fioretti Alice Tolomei Piera Ciaramella Antonio Lio Ernesto Cristiano Giulio Cacioli Federica Tempestini Federico Ranocchi Viviana Maestrini Amedeo Pergolini Echocardiography ABSTRACTBackgroundPreoperative echocardiographic assessment is critical for patients with severe degenerative mitral regurgitation to ensure personalized surgical mitral valve repair. This study aimed to compare the diagnostic accuracy of three‐dimensional transthoracic echocardiography (3D TTE) and three‐dimensional transesophageal echocardiography (3D TEE) in identifying valvular lesions, using surgical findings as the reference. Additionally, we evaluated whether annular dimensional parameters derived from TTE and TEE, using dedicated 3D software, could confirm whether 3D TTE alone offers a comprehensive preoperative evaluation.MethodsWe enrolled 60 patients with severe organic mitral regurgitation scheduled for surgical valve repair. Each patient underwent preoperative 3D TTE, intraoperative 3D TEE prior to surgery, followed by annuloplasty. Mitral valve reconstructions from both TTE and TEE were compared, and dedicated 3D software (EchoPAC GE‐Health‐Care Software 3D‐auto‐MVQ) was employed to reconstruct annular geometries from both methods.ResultsBoth 3D TTE and 3D TEE demonstrated comparable accuracy in identifying diseased scallops (overall accuracy: 3D TTE 91.8%, 3D TEE 98.1%, p > 0.05). However, 3D TTE was inferior to 3D TEE in identifying multiple chordal ruptures (accuracy: 3D TTE 80%, 3D TEE 100%). Quantitative analysis of the mitral annulus revealed that 3D TTE and 3D TEE yielded overlapping results for static parameters (p > 0.05), whereas dynamic parameters differed significantly (p < 0.05).ConclusionsIn the selected population, 3D TTE demonstrated diagnostic accuracy comparable to transesophageal echocardiography in identifying mitral valve lesions. Furthermore, with the use of dedicated 3D software, TTE alone may provide a comprehensive and noninvasive preoperative evaluation, particularly for static annular parameters. Further studies are warranted to corroborate these findings. 10.1111/echo.70040 http://onlinelibrary.wiley.com/termsAndConditions#vor
doi_str_mv 10.1111/echo.70040
format Artículo Open Access
id wiley_oa_10_1111_echo_70040
institution Wiley Open Access
license_str_mv http://onlinelibrary.wiley.com/termsAndConditions#vor
publishDate 2024
publisher Wiley
record_format wiley_oa
spellingShingle Study of Degenerative Mitral Regurgitation Using Three‐Dimensional Echocardiography and EchoPAC GE Health Care Software 4D Auto MVQ: Comparison Between Transthoracic and Transesophageal Examination
Ginevra Fioretti
Alice Tolomei
Piera Ciaramella
Antonio Lio
Ernesto Cristiano
Giulio Cacioli
Federica Tempestini
Federico Ranocchi
Viviana Maestrini
Amedeo Pergolini
Echocardiography
Study of Degenerative Mitral Regurgitation Using Three‐Dimensional Echocardiography and EchoPAC GE Health Care Software 4D Auto MVQ: Comparison Between Transthoracic and Transesophageal Examination Ginevra Fioretti Alice Tolomei Piera Ciaramella Antonio Lio Ernesto Cristiano Giulio Cacioli Federica Tempestini Federico Ranocchi Viviana Maestrini Amedeo Pergolini Echocardiography ABSTRACTBackgroundPreoperative echocardiographic assessment is critical for patients with severe degenerative mitral regurgitation to ensure personalized surgical mitral valve repair. This study aimed to compare the diagnostic accuracy of three‐dimensional transthoracic echocardiography (3D TTE) and three‐dimensional transesophageal echocardiography (3D TEE) in identifying valvular lesions, using surgical findings as the reference. Additionally, we evaluated whether annular dimensional parameters derived from TTE and TEE, using dedicated 3D software, could confirm whether 3D TTE alone offers a comprehensive preoperative evaluation.MethodsWe enrolled 60 patients with severe organic mitral regurgitation scheduled for surgical valve repair. Each patient underwent preoperative 3D TTE, intraoperative 3D TEE prior to surgery, followed by annuloplasty. Mitral valve reconstructions from both TTE and TEE were compared, and dedicated 3D software (EchoPAC GE‐Health‐Care Software 3D‐auto‐MVQ) was employed to reconstruct annular geometries from both methods.ResultsBoth 3D TTE and 3D TEE demonstrated comparable accuracy in identifying diseased scallops (overall accuracy: 3D TTE 91.8%, 3D TEE 98.1%, p > 0.05). However, 3D TTE was inferior to 3D TEE in identifying multiple chordal ruptures (accuracy: 3D TTE 80%, 3D TEE 100%). Quantitative analysis of the mitral annulus revealed that 3D TTE and 3D TEE yielded overlapping results for static parameters (p > 0.05), whereas dynamic parameters differed significantly (p < 0.05).ConclusionsIn the selected population, 3D TTE demonstrated diagnostic accuracy comparable to transesophageal echocardiography in identifying mitral valve lesions. Furthermore, with the use of dedicated 3D software, TTE alone may provide a comprehensive and noninvasive preoperative evaluation, particularly for static annular parameters. Further studies are warranted to corroborate these findings. 10.1111/echo.70040 http://onlinelibrary.wiley.com/termsAndConditions#vor
title Study of Degenerative Mitral Regurgitation Using Three‐Dimensional Echocardiography and EchoPAC GE Health Care Software 4D Auto MVQ: Comparison Between Transthoracic and Transesophageal Examination
topic Echocardiography
url https://onlinelibrary.wiley.com/doi/10.1111/echo.70040