Spontaneous termination of ventricular tachycardia in the human heart

Fuente: Wiley Open Access
Saved in:
Bibliographic Details
Main Authors: Takahiro Hayashi, Nathan Denham, Chloe Nettlefold, Jayant Kakarla, Robert Anderson, Abhishek Bhaskaran, Stéphane Massé, Eugene Downar, Kumaraswamy Nanthakumar
Format: Artículo Open Access
Published: Wiley 2024
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1867015572691091456
author Takahiro Hayashi
Nathan Denham
Chloe Nettlefold
Jayant Kakarla
Robert Anderson
Abhishek Bhaskaran
Stéphane Massé
Eugene Downar
Kumaraswamy Nanthakumar
author_facet Takahiro Hayashi
Nathan Denham
Chloe Nettlefold
Jayant Kakarla
Robert Anderson
Abhishek Bhaskaran
Stéphane Massé
Eugene Downar
Kumaraswamy Nanthakumar
Takahiro Hayashi
Nathan Denham
Chloe Nettlefold
Jayant Kakarla
Robert Anderson
Abhishek Bhaskaran
Stéphane Massé
Eugene Downar
Kumaraswamy Nanthakumar
collection Wiley Open Access
contents Spontaneous termination of ventricular tachycardia in the human heart Takahiro Hayashi Nathan Denham Chloe Nettlefold Jayant Kakarla Robert Anderson Abhishek Bhaskaran Stéphane Massé Eugene Downar Kumaraswamy Nanthakumar Journal of Cardiovascular Electrophysiology AbstractIntroductionUnderstanding the spatiotemporal location of the spontaneous termination of ventricular tachycardia (VT) may provide new insights for ablation. To test the hypothesis that spontaneous VT termination most frequently occurs at the VT exit due to source‐sink mismatch and to characterize electrophysiological properties of the sites termination during VT and with extra‐stimulus technique.MethodsRetrospective analysis of intraoperative mapping studies of nine patients with ischemic cardiopathy or repaired tetralogy of Fallot. Simultaneous endocardial and epicardial mapping was performed in both ventricles using a custom mapping array during VT. Electrogram (EGM) characteristics before and at the moment of termination were analyzed including: cycle length oscillations, EGM heterogeneity and a variation in the systolic/diastolic path. The decrements to extra stimulus were analysed for termination sites and other diastolic sites.ResultsNine VTs in seven patients demonstrated spontaneous VT termination. Seven VTs (77.8%) spontaneously terminated in the final third of the systolic interval, one (11.1%) in early diastole and one (11.1%) in mid diastole. Cycle length oscillations (prolongation, shortening, and no change) were seen in equal frequency. Four VTs (44.4%) showed alternans in the local EGM at the site of termination and this was more prevalent than alternans at other sites in the diastolic pathway (p < .001). Only one‐third of VTs showed a change in activation pattern before termination. There was no difference based on etiology. During substrate characterization with extra‐stimulus pacing, sites of spontaneous termination showed greater decrement than other sites of the VT circuit during pacing (43.5 ± 14.5 ms vs. 31.2 ± 31.2 ms; p = .003).ConclusionThe entrance zone rather than the exit is the commonest site for the spontaneous termination of VT in the human heart. These sites tend to demonstrate EGM alternans during VT and greater decrement during extrastimulus pacing. These findings may help guide future studies into improving the success of VT ablation. 10.1111/jce.16421 http://creativecommons.org/licenses/by/4.0/
doi_str_mv 10.1111/jce.16421
format Artículo Open Access
id wiley_oa_10_1111_jce_16421
institution Wiley Open Access
license_str_mv http://creativecommons.org/licenses/by/4.0/
publishDate 2024
publisher Wiley
record_format wiley_oa
spellingShingle Spontaneous termination of ventricular tachycardia in the human heart
Takahiro Hayashi
Nathan Denham
Chloe Nettlefold
Jayant Kakarla
Robert Anderson
Abhishek Bhaskaran
Stéphane Massé
Eugene Downar
Kumaraswamy Nanthakumar
Journal of Cardiovascular Electrophysiology
Spontaneous termination of ventricular tachycardia in the human heart Takahiro Hayashi Nathan Denham Chloe Nettlefold Jayant Kakarla Robert Anderson Abhishek Bhaskaran Stéphane Massé Eugene Downar Kumaraswamy Nanthakumar Journal of Cardiovascular Electrophysiology AbstractIntroductionUnderstanding the spatiotemporal location of the spontaneous termination of ventricular tachycardia (VT) may provide new insights for ablation. To test the hypothesis that spontaneous VT termination most frequently occurs at the VT exit due to source‐sink mismatch and to characterize electrophysiological properties of the sites termination during VT and with extra‐stimulus technique.MethodsRetrospective analysis of intraoperative mapping studies of nine patients with ischemic cardiopathy or repaired tetralogy of Fallot. Simultaneous endocardial and epicardial mapping was performed in both ventricles using a custom mapping array during VT. Electrogram (EGM) characteristics before and at the moment of termination were analyzed including: cycle length oscillations, EGM heterogeneity and a variation in the systolic/diastolic path. The decrements to extra stimulus were analysed for termination sites and other diastolic sites.ResultsNine VTs in seven patients demonstrated spontaneous VT termination. Seven VTs (77.8%) spontaneously terminated in the final third of the systolic interval, one (11.1%) in early diastole and one (11.1%) in mid diastole. Cycle length oscillations (prolongation, shortening, and no change) were seen in equal frequency. Four VTs (44.4%) showed alternans in the local EGM at the site of termination and this was more prevalent than alternans at other sites in the diastolic pathway (p < .001). Only one‐third of VTs showed a change in activation pattern before termination. There was no difference based on etiology. During substrate characterization with extra‐stimulus pacing, sites of spontaneous termination showed greater decrement than other sites of the VT circuit during pacing (43.5 ± 14.5 ms vs. 31.2 ± 31.2 ms; p = .003).ConclusionThe entrance zone rather than the exit is the commonest site for the spontaneous termination of VT in the human heart. These sites tend to demonstrate EGM alternans during VT and greater decrement during extrastimulus pacing. These findings may help guide future studies into improving the success of VT ablation. 10.1111/jce.16421 http://creativecommons.org/licenses/by/4.0/
title Spontaneous termination of ventricular tachycardia in the human heart
topic Journal of Cardiovascular Electrophysiology
url https://onlinelibrary.wiley.com/doi/10.1111/jce.16421