Intracardiac echocardiography guided electrified J‐wire trans‐septal puncture: A prospective randomized controlled trial

Fuente: Wiley Open Access
Salvato in:
Dettagli Bibliografici
Autori principali: Hui Cheng, Abdul Basit Bangash, Yuhang Tao, Ruhong Jiang, Qiang Liu, Cheng Cheng, Guosheng Fu, Chenyang Jiang
Natura: Artículo Open Access
Pubblicazione: Wiley 2024
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1867003171355754496
author Hui Cheng
Abdul Basit Bangash
Yuhang Tao
Ruhong Jiang
Qiang Liu
Cheng Cheng
Guosheng Fu
Chenyang Jiang
author_facet Hui Cheng
Abdul Basit Bangash
Yuhang Tao
Ruhong Jiang
Qiang Liu
Cheng Cheng
Guosheng Fu
Chenyang Jiang
Hui Cheng
Abdul Basit Bangash
Yuhang Tao
Ruhong Jiang
Qiang Liu
Cheng Cheng
Guosheng Fu
Chenyang Jiang
collection Wiley Open Access
contents Intracardiac echocardiography guided electrified J‐wire trans‐septal puncture: A prospective randomized controlled trial Hui Cheng Abdul Basit Bangash Yuhang Tao Ruhong Jiang Qiang Liu Cheng Cheng Guosheng Fu Chenyang Jiang Pacing and Clinical Electrophysiology AbstractBackgroundApplication of electrocautery to a J‐wire is used to perform transseptal puncture (TSP), but with limited evidence supporting safety and efficacy. We conducted a prospective randomized controlled trial to evaluate the safety and efficacy of this technique.MethodsTwo hundred consecutive patients were randomized in a 1:1 fashion to either the ICE‐guided electrified J‐wire TSP group or a conventional Brockenbrough (BRK) needle TSP group. The TSP was performed with a 0.032″ guidewire under 20 W, “coag” mode and was compared to TSP using the BRK needle. The primary safety endpoints were complications related to TSP. The primary efficacy endpoints included the TSP success rate, the total TSP time, and the total procedure time.ResultsAll patients complete the procedure safely. The electrified J‐wire TSP group had a significantly shorter TSP time than BRK needle TSP group. The total procedure time, number of TSP attempts required to achieve successful LA access, width of the intra‐atrial shunt at the end of ablation were similar between the two groups. The incidence of new cerebral infarction detected by MRI were similar between the two groups (3/32 patients in the J‐wire TSP group and 2/26 patients in conventional BRK TSP group, p = .82). And no difference in the incidence of residual intra‐atrial shunt (4.3% vs. 6%, p = .654) during the 3‐month's follow up.ConclusionUsing an electrified J‐wire for TSP under the guidance of ICE appears to be as safe as and more efficient than conventional BRK needle TSP, which may be especially useful in the era of non‐fluoroscopy AF ablation. 10.1111/pace.14916 http://onlinelibrary.wiley.com/termsAndConditions#vor
doi_str_mv 10.1111/pace.14916
format Artículo Open Access
id wiley_oa_10_1111_pace_14916
institution Wiley Open Access
license_str_mv http://onlinelibrary.wiley.com/termsAndConditions#vor
publishDate 2024
publisher Wiley
record_format wiley_oa
spellingShingle Intracardiac echocardiography guided electrified J‐wire trans‐septal puncture: A prospective randomized controlled trial
Hui Cheng
Abdul Basit Bangash
Yuhang Tao
Ruhong Jiang
Qiang Liu
Cheng Cheng
Guosheng Fu
Chenyang Jiang
Pacing and Clinical Electrophysiology
Intracardiac echocardiography guided electrified J‐wire trans‐septal puncture: A prospective randomized controlled trial Hui Cheng Abdul Basit Bangash Yuhang Tao Ruhong Jiang Qiang Liu Cheng Cheng Guosheng Fu Chenyang Jiang Pacing and Clinical Electrophysiology AbstractBackgroundApplication of electrocautery to a J‐wire is used to perform transseptal puncture (TSP), but with limited evidence supporting safety and efficacy. We conducted a prospective randomized controlled trial to evaluate the safety and efficacy of this technique.MethodsTwo hundred consecutive patients were randomized in a 1:1 fashion to either the ICE‐guided electrified J‐wire TSP group or a conventional Brockenbrough (BRK) needle TSP group. The TSP was performed with a 0.032″ guidewire under 20 W, “coag” mode and was compared to TSP using the BRK needle. The primary safety endpoints were complications related to TSP. The primary efficacy endpoints included the TSP success rate, the total TSP time, and the total procedure time.ResultsAll patients complete the procedure safely. The electrified J‐wire TSP group had a significantly shorter TSP time than BRK needle TSP group. The total procedure time, number of TSP attempts required to achieve successful LA access, width of the intra‐atrial shunt at the end of ablation were similar between the two groups. The incidence of new cerebral infarction detected by MRI were similar between the two groups (3/32 patients in the J‐wire TSP group and 2/26 patients in conventional BRK TSP group, p = .82). And no difference in the incidence of residual intra‐atrial shunt (4.3% vs. 6%, p = .654) during the 3‐month's follow up.ConclusionUsing an electrified J‐wire for TSP under the guidance of ICE appears to be as safe as and more efficient than conventional BRK needle TSP, which may be especially useful in the era of non‐fluoroscopy AF ablation. 10.1111/pace.14916 http://onlinelibrary.wiley.com/termsAndConditions#vor
title Intracardiac echocardiography guided electrified J‐wire trans‐septal puncture: A prospective randomized controlled trial
topic Pacing and Clinical Electrophysiology
url https://onlinelibrary.wiley.com/doi/10.1111/pace.14916