Patients with a high defibrillation threshold: Approaches to management

Fuente: Wiley Open Access
Enregistré dans:
Détails bibliographiques
Auteurs principaux: Alejandro Vidal Margenat, Ahmed Zedan, Scott Schubert, Srushti Gopani, Ramesh Hariharan
Format: Artículo Open Access
Publié: Wiley 2024
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1867008897987903488
author Alejandro Vidal Margenat
Ahmed Zedan
Scott Schubert
Srushti Gopani
Ramesh Hariharan
author_facet Alejandro Vidal Margenat
Ahmed Zedan
Scott Schubert
Srushti Gopani
Ramesh Hariharan
Alejandro Vidal Margenat
Ahmed Zedan
Scott Schubert
Srushti Gopani
Ramesh Hariharan
collection Wiley Open Access
contents Patients with a high defibrillation threshold: Approaches to management Alejandro Vidal Margenat Ahmed Zedan Scott Schubert Srushti Gopani Ramesh Hariharan Pacing and Clinical Electrophysiology AbstractImplantable cardioverter‐defibrillators (ICDs) have revolutionized the prognosis for patients at elevated risk of ventricular tachyarrhythmias. For safety, defibrillation should be effective with a minimum of 10 J below the device's maximum energy. While modern ICDs rarely deliver ineffective shocks in primary prevention, the surge in managing severe heart failure patients has led to an increased number of patients with high defibrillation thresholds (DFTs). This article elucidates the potential causes of high DFT, including clinical factors, lead and device placement, the presence of a Left Ventricular Assist Device (LVAD), prolonged ventricular arrhythmias, shock vectors, waveform tilt, medications, and manufacturer‐specific options. We also detail management strategies, highlighting alternative shock coil placements, practical recommendations, and case studies from our institution. Our management algorithm suggests addressing preventable causes, re‐evaluating coil positions, considering non‐invasive system modifications, upgrading to a higher‐capacity device, and adding extra coil(s). 10.1111/pace.14936 http://onlinelibrary.wiley.com/termsAndConditions#vor
doi_str_mv 10.1111/pace.14936
format Artículo Open Access
id wiley_oa_10_1111_pace_14936
institution Wiley Open Access
license_str_mv http://onlinelibrary.wiley.com/termsAndConditions#vor
publishDate 2024
publisher Wiley
record_format wiley_oa
spellingShingle Patients with a high defibrillation threshold: Approaches to management
Alejandro Vidal Margenat
Ahmed Zedan
Scott Schubert
Srushti Gopani
Ramesh Hariharan
Pacing and Clinical Electrophysiology
Patients with a high defibrillation threshold: Approaches to management Alejandro Vidal Margenat Ahmed Zedan Scott Schubert Srushti Gopani Ramesh Hariharan Pacing and Clinical Electrophysiology AbstractImplantable cardioverter‐defibrillators (ICDs) have revolutionized the prognosis for patients at elevated risk of ventricular tachyarrhythmias. For safety, defibrillation should be effective with a minimum of 10 J below the device's maximum energy. While modern ICDs rarely deliver ineffective shocks in primary prevention, the surge in managing severe heart failure patients has led to an increased number of patients with high defibrillation thresholds (DFTs). This article elucidates the potential causes of high DFT, including clinical factors, lead and device placement, the presence of a Left Ventricular Assist Device (LVAD), prolonged ventricular arrhythmias, shock vectors, waveform tilt, medications, and manufacturer‐specific options. We also detail management strategies, highlighting alternative shock coil placements, practical recommendations, and case studies from our institution. Our management algorithm suggests addressing preventable causes, re‐evaluating coil positions, considering non‐invasive system modifications, upgrading to a higher‐capacity device, and adding extra coil(s). 10.1111/pace.14936 http://onlinelibrary.wiley.com/termsAndConditions#vor
title Patients with a high defibrillation threshold: Approaches to management
topic Pacing and Clinical Electrophysiology
url https://onlinelibrary.wiley.com/doi/10.1111/pace.14936