Saved in:
Bibliographic Details
Main Authors: Alberto Preda, Francesco Melillo, Matteo Baroni, Alessandra Marzi, Vincenzo Schillaci, Sara Vargiu, Andrea Caccia, Fabrizio Guarracini, Lorenzo Gigli, Gabriele Paglino, Giulia Massaro, Igor Diemberger, Giosuè Mascioli, Francesco Solimene, Patrizio Mazzone
Format: Artículo Open Access
Published: Wiley 2025
Subjects:
Online Access:https://onlinelibrary.wiley.com/doi/10.1111/pace.15146
Tags: Add Tag
No Tags, Be the first to tag this record!
Table of Contents:
  • Multicentric Experience With the Use of Short 13Fr Mechanical Rotating Dilator Sheath for Transvenous Lead Extraction Alberto Preda Francesco Melillo Matteo Baroni Alessandra Marzi Vincenzo Schillaci Sara Vargiu Andrea Caccia Fabrizio Guarracini Lorenzo Gigli Gabriele Paglino Giulia Massaro Igor Diemberger Giosuè Mascioli Francesco Solimene Patrizio Mazzone Pacing and Clinical Electrophysiology ABSTRACTBackgroundThe need for transvenous lead extraction (TLE) is increasing worldwide. Since the course of the subclavian vein until the junction with the superior vena cava is a frequent place of lead adherences, we aim to assess the safety and efficacy of a short 13Fr bidirectional rotational mechanical sheath as first choice.Methods and ResultsIn this multicentric study, 202 carriers of a cardiac implantable electronic device (CIED) undergoing TLE using a short 13 Fr bidirectional rotational mechanical sheath were prospectively enrolled. All procedures were performed using a stepwise approach. The indication for TLE were infection (62%), malfunction (32%), and upgrade (6%). Overall, 471 leads were extracted: 65% pacing leads, 20% defibrillator leads, 9% coronary sinus leads, and 6% abandoned leads. Clinical success and complete lead extraction have been achieved in 97% and 95% of cases, respectively. The short sheath was always effective in gaining venous access at the start of the procedure and was sufficient for complete TLE in 67% of cases. Lead dwell time, defibrillator lead, number of leads per patient, and lead malfunction were predicting factors of long bidirectional rotational mechanical sheath use. There were no cases of intraprocedural death, and major complications were reported in 2% of patients. Overall survival was 97% at 1‐year follow‐up.ConclusionThis multicentric experience using a short 13Fr bidirectional rotational mechanical sheath reported high safety and efficacy, demonstrating the utility of routine use of short extraction sheaths of higher caliper as the first choice. 10.1111/pace.15146 http://onlinelibrary.wiley.com/termsAndConditions#vor