Extravascular ICD as a Viable Solution After CIED Lead Extraction: A Case Report

Fuente: Wiley Open Access
Enregistré dans:
Détails bibliographiques
Auteurs principaux: Giuseppe Coppola, Salvatore Torre, Leonardo D'Amico, Amedeo Calè, Alfredo R. Galassi, Egle Corrado
Format: Artículo Open Access
Publié: Wiley 2025
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1867013054324015104
author Giuseppe Coppola
Salvatore Torre
Leonardo D'Amico
Amedeo Calè
Alfredo R. Galassi
Egle Corrado
author_facet Giuseppe Coppola
Salvatore Torre
Leonardo D'Amico
Amedeo Calè
Alfredo R. Galassi
Egle Corrado
Giuseppe Coppola
Salvatore Torre
Leonardo D'Amico
Amedeo Calè
Alfredo R. Galassi
Egle Corrado
collection Wiley Open Access
contents Extravascular ICD as a Viable Solution After CIED Lead Extraction: A Case Report Giuseppe Coppola Salvatore Torre Leonardo D'Amico Amedeo Calè Alfredo R. Galassi Egle Corrado Pacing and Clinical Electrophysiology ABSTRACT Post‐implantation infections of pacemakers or defibrillators represent a serious complication, impacting patient morbidity and mortality. We present a case involving a 75‐year‐old male with multiple comorbidities who developed pocket erosion of a previously implanted biventricular defibrillator, complicated by Staphylococcus haemolyticus infection. Following device extraction and targeted antibiotic therapy, an extravascular implantable cardioverter defibrillator (EV‐ICD; Aurora EV‐ICD) was implanted. The procedure was successfully performed, with a 2‐month follow‐up showing no signs of infection or device displacement. EV‐ICD appears to be a safe and effective alternative for high‐risk patients, minimizing complications associated with vascular access and endocardial lead implantation. 10.1111/pace.70045 http://onlinelibrary.wiley.com/termsAndConditions#vor
doi_str_mv 10.1111/pace.70045
format Artículo Open Access
id wiley_oa_10_1111_pace_70045
institution Wiley Open Access
license_str_mv http://onlinelibrary.wiley.com/termsAndConditions#vor
publishDate 2025
publisher Wiley
record_format wiley_oa
spellingShingle Extravascular ICD as a Viable Solution After CIED Lead Extraction: A Case Report
Giuseppe Coppola
Salvatore Torre
Leonardo D'Amico
Amedeo Calè
Alfredo R. Galassi
Egle Corrado
Pacing and Clinical Electrophysiology
Extravascular ICD as a Viable Solution After CIED Lead Extraction: A Case Report Giuseppe Coppola Salvatore Torre Leonardo D'Amico Amedeo Calè Alfredo R. Galassi Egle Corrado Pacing and Clinical Electrophysiology ABSTRACT Post‐implantation infections of pacemakers or defibrillators represent a serious complication, impacting patient morbidity and mortality. We present a case involving a 75‐year‐old male with multiple comorbidities who developed pocket erosion of a previously implanted biventricular defibrillator, complicated by Staphylococcus haemolyticus infection. Following device extraction and targeted antibiotic therapy, an extravascular implantable cardioverter defibrillator (EV‐ICD; Aurora EV‐ICD) was implanted. The procedure was successfully performed, with a 2‐month follow‐up showing no signs of infection or device displacement. EV‐ICD appears to be a safe and effective alternative for high‐risk patients, minimizing complications associated with vascular access and endocardial lead implantation. 10.1111/pace.70045 http://onlinelibrary.wiley.com/termsAndConditions#vor
title Extravascular ICD as a Viable Solution After CIED Lead Extraction: A Case Report
topic Pacing and Clinical Electrophysiology
url https://onlinelibrary.wiley.com/doi/10.1111/pace.70045