Antimicrobial Envelopes for Cardiac Device Infection Prevention: A Meta‐Analysis of Randomized and Matched Studies

Fuente: Wiley Open Access
Enregistré dans:
Détails bibliographiques
Auteurs principaux: Alonzo Armani Prata, Luís Fernando Ferreira Cavalcante, Gabriela Blanco Stutz, Thalia Melamed, Caio Rezende Lima, Andrew H. Locke, Alexandra Régia Dantas Brígido
Format: Artículo Open Access
Publié: Wiley 2025
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1867010230860120064
author Alonzo Armani Prata
Luís Fernando Ferreira Cavalcante
Gabriela Blanco Stutz
Thalia Melamed
Caio Rezende Lima
Andrew H. Locke
Alexandra Régia Dantas Brígido
author_facet Alonzo Armani Prata
Luís Fernando Ferreira Cavalcante
Gabriela Blanco Stutz
Thalia Melamed
Caio Rezende Lima
Andrew H. Locke
Alexandra Régia Dantas Brígido
Alonzo Armani Prata
Luís Fernando Ferreira Cavalcante
Gabriela Blanco Stutz
Thalia Melamed
Caio Rezende Lima
Andrew H. Locke
Alexandra Régia Dantas Brígido
collection Wiley Open Access
contents Antimicrobial Envelopes for Cardiac Device Infection Prevention: A Meta‐Analysis of Randomized and Matched Studies Alonzo Armani Prata Luís Fernando Ferreira Cavalcante Gabriela Blanco Stutz Thalia Melamed Caio Rezende Lima Andrew H. Locke Alexandra Régia Dantas Brígido Pacing and Clinical Electrophysiology ABSTRACT Introduction Cardiac implantable electronic device (CIED)‐associated infections are a significant procedural complication. Antibacterial envelopes have emerged as a potential strategy to mitigate this risk, though the evidence regarding their prognostic benefit remains inconclusive. Objectives We performed a meta‐analysis of randomized controlled trials (RCTs) and propensity score–matched cohorts evaluating the efficacy of the adjunctive use of antimicrobial envelopes in preventing CIED‐related infections compared to standard prophylactic measures alone. Methods We searched through PubMed, Cochrane, and Embase databases. Our primary outcomes were (1) any CIED‐related infection and (2) major CIED‐related infection. We conducted a sensitivity analysis in high‐risk patients. Results A total of one RCT and eight observational studies were included, involving 78,587 patients, of whom 12,290 (15.6%) received antimicrobial envelopes. The overall risk ratio (RR) analysis showed no significant difference in the incidence of any CIED‐related infections between the antimicrobial envelope and standard prophylaxis groups (RR 0.55; 95% CI 0.30–1.01; I 2 = 75%). However, time‐to‐event analysis demonstrated that the use of antimicrobial envelopes was associated with a significantly lower risk of any CIED‐related infection [hazard ratio (HR) 0.38; 95% CI 0.17–0.87; I 2 = 67%] and major CIED‐related infection (HR 0.54; 95% CI 0.39–0.76; I 2 = 0%). Moreover, among high‐risk patients, envelope implantation significantly reduced infection risk (RR 0.64; 95% CI 0.47–0.88; I 2 = 22%). Conclusion Our analysis demonstrates that antibacterial envelopes significantly reduce the risk of CIED‐related infections, particularly in high‐risk patients. Although the additional cost remains a consideration, the time‐to‐event findings and benefit observed in selected high‐risk populations may support their use in appropriately stratified patients. 10.1111/pace.70108 http://onlinelibrary.wiley.com/termsAndConditions#vor
doi_str_mv 10.1111/pace.70108
format Artículo Open Access
id wiley_oa_10_1111_pace_70108
institution Wiley Open Access
license_str_mv http://onlinelibrary.wiley.com/termsAndConditions#vor
publishDate 2025
publisher Wiley
record_format wiley_oa
spellingShingle Antimicrobial Envelopes for Cardiac Device Infection Prevention: A Meta‐Analysis of Randomized and Matched Studies
Alonzo Armani Prata
Luís Fernando Ferreira Cavalcante
Gabriela Blanco Stutz
Thalia Melamed
Caio Rezende Lima
Andrew H. Locke
Alexandra Régia Dantas Brígido
Pacing and Clinical Electrophysiology
Antimicrobial Envelopes for Cardiac Device Infection Prevention: A Meta‐Analysis of Randomized and Matched Studies Alonzo Armani Prata Luís Fernando Ferreira Cavalcante Gabriela Blanco Stutz Thalia Melamed Caio Rezende Lima Andrew H. Locke Alexandra Régia Dantas Brígido Pacing and Clinical Electrophysiology ABSTRACT Introduction Cardiac implantable electronic device (CIED)‐associated infections are a significant procedural complication. Antibacterial envelopes have emerged as a potential strategy to mitigate this risk, though the evidence regarding their prognostic benefit remains inconclusive. Objectives We performed a meta‐analysis of randomized controlled trials (RCTs) and propensity score–matched cohorts evaluating the efficacy of the adjunctive use of antimicrobial envelopes in preventing CIED‐related infections compared to standard prophylactic measures alone. Methods We searched through PubMed, Cochrane, and Embase databases. Our primary outcomes were (1) any CIED‐related infection and (2) major CIED‐related infection. We conducted a sensitivity analysis in high‐risk patients. Results A total of one RCT and eight observational studies were included, involving 78,587 patients, of whom 12,290 (15.6%) received antimicrobial envelopes. The overall risk ratio (RR) analysis showed no significant difference in the incidence of any CIED‐related infections between the antimicrobial envelope and standard prophylaxis groups (RR 0.55; 95% CI 0.30–1.01; I 2 = 75%). However, time‐to‐event analysis demonstrated that the use of antimicrobial envelopes was associated with a significantly lower risk of any CIED‐related infection [hazard ratio (HR) 0.38; 95% CI 0.17–0.87; I 2 = 67%] and major CIED‐related infection (HR 0.54; 95% CI 0.39–0.76; I 2 = 0%). Moreover, among high‐risk patients, envelope implantation significantly reduced infection risk (RR 0.64; 95% CI 0.47–0.88; I 2 = 22%). Conclusion Our analysis demonstrates that antibacterial envelopes significantly reduce the risk of CIED‐related infections, particularly in high‐risk patients. Although the additional cost remains a consideration, the time‐to‐event findings and benefit observed in selected high‐risk populations may support their use in appropriately stratified patients. 10.1111/pace.70108 http://onlinelibrary.wiley.com/termsAndConditions#vor
title Antimicrobial Envelopes for Cardiac Device Infection Prevention: A Meta‐Analysis of Randomized and Matched Studies
topic Pacing and Clinical Electrophysiology
url https://onlinelibrary.wiley.com/doi/10.1111/pace.70108