Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Nicolò Sisti, Andrea Cardona, Ludovico Lazzari, Federico Fortuni, Amato Santoro, Chiara Andreoli, Francesco Notaristefano, Giovanni Carreras
Format: Artículo Open Access
Veröffentlicht: Wiley 2026
Schlagworte:
Online-Zugang:https://onlinelibrary.wiley.com/doi/10.1111/pace.70149
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
_version_ 1867021914067697664
author Nicolò Sisti
Andrea Cardona
Ludovico Lazzari
Federico Fortuni
Amato Santoro
Chiara Andreoli
Francesco Notaristefano
Giovanni Carreras
author_facet Nicolò Sisti
Andrea Cardona
Ludovico Lazzari
Federico Fortuni
Amato Santoro
Chiara Andreoli
Francesco Notaristefano
Giovanni Carreras
Nicolò Sisti
Andrea Cardona
Ludovico Lazzari
Federico Fortuni
Amato Santoro
Chiara Andreoli
Francesco Notaristefano
Giovanni Carreras
collection Wiley Open Access
contents When Substrate Meets Device: ICD Implantation and Therapy across the Spectrum of Cardiomyopathies Nicolò Sisti Andrea Cardona Ludovico Lazzari Federico Fortuni Amato Santoro Chiara Andreoli Francesco Notaristefano Giovanni Carreras Pacing and Clinical Electrophysiology ABSTRACT Introduction Implantable cardioverter‐defibrillators (ICDs) are the cornerstone of sudden cardiac death prevention in cardiomyopathies, but disease‐specific structural and electrophysiological substrates profoundly affect device performance and outcomes. Understanding these distinctions is critical for tailoring therapy and improving patient safety. Areas covered This review examines current evidence and practical experience regarding ICD implantation, programming, and management in hypertrophic cardiomyopathy (HCM), arrhythmogenic right ventricular cardiomyopathy (ARVC), and cardiac amyloidosis (CA). We performed a structured narrative synthesis to identify phenotype‐specific technical challenges, programming strategies, and complication trends. For HCM, lead placement and programming to minimize inappropriate therapies are emphasized; for ARVC, issues of lead instability, oversensing, and ATP efficacy are explored; and for CA, defibrillation thresholds, sensing difficulties, and individualized indications are discussed. Expert opinion ICD therapy in cardiomyopathies must be individualized, balancing arrhythmic protection against disease‐specific risks and device‐related complications. Tailored programming, careful system selection, and remote monitoring are key to improving outcomes. Emerging technologies such as modular and extravascular ICD systems promise safer and more phenotype‐driven care. 10.1111/pace.70149 http://onlinelibrary.wiley.com/termsAndConditions#vor
doi_str_mv 10.1111/pace.70149
format Artículo Open Access
id wiley_oa_10_1111_pace_70149
institution Wiley Open Access
license_str_mv http://onlinelibrary.wiley.com/termsAndConditions#vor
publishDate 2026
publisher Wiley
record_format wiley_oa
spellingShingle When Substrate Meets Device: ICD Implantation and Therapy across the Spectrum of Cardiomyopathies
Nicolò Sisti
Andrea Cardona
Ludovico Lazzari
Federico Fortuni
Amato Santoro
Chiara Andreoli
Francesco Notaristefano
Giovanni Carreras
Pacing and Clinical Electrophysiology
When Substrate Meets Device: ICD Implantation and Therapy across the Spectrum of Cardiomyopathies Nicolò Sisti Andrea Cardona Ludovico Lazzari Federico Fortuni Amato Santoro Chiara Andreoli Francesco Notaristefano Giovanni Carreras Pacing and Clinical Electrophysiology ABSTRACT Introduction Implantable cardioverter‐defibrillators (ICDs) are the cornerstone of sudden cardiac death prevention in cardiomyopathies, but disease‐specific structural and electrophysiological substrates profoundly affect device performance and outcomes. Understanding these distinctions is critical for tailoring therapy and improving patient safety. Areas covered This review examines current evidence and practical experience regarding ICD implantation, programming, and management in hypertrophic cardiomyopathy (HCM), arrhythmogenic right ventricular cardiomyopathy (ARVC), and cardiac amyloidosis (CA). We performed a structured narrative synthesis to identify phenotype‐specific technical challenges, programming strategies, and complication trends. For HCM, lead placement and programming to minimize inappropriate therapies are emphasized; for ARVC, issues of lead instability, oversensing, and ATP efficacy are explored; and for CA, defibrillation thresholds, sensing difficulties, and individualized indications are discussed. Expert opinion ICD therapy in cardiomyopathies must be individualized, balancing arrhythmic protection against disease‐specific risks and device‐related complications. Tailored programming, careful system selection, and remote monitoring are key to improving outcomes. Emerging technologies such as modular and extravascular ICD systems promise safer and more phenotype‐driven care. 10.1111/pace.70149 http://onlinelibrary.wiley.com/termsAndConditions#vor
title When Substrate Meets Device: ICD Implantation and Therapy across the Spectrum of Cardiomyopathies
topic Pacing and Clinical Electrophysiology
url https://onlinelibrary.wiley.com/doi/10.1111/pace.70149