Accuracy and Reliability of Telediagnosis Approach for Canine and Feline Ophthalmological Emergencies: A Retrospective Study of 100 Cases

Fuente: Wiley Open Access
Saved in:
Bibliographic Details
Main Authors: Marion Phélip, Coline Jondeau, Matthieu Bott, Aure‐Eline Grillot, Sabine Chahory
Format: Artículo Open Access
Published: Wiley 2025
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1867020003242409984
author Marion Phélip
Coline Jondeau
Matthieu Bott
Aure‐Eline Grillot
Sabine Chahory
author_facet Marion Phélip
Coline Jondeau
Matthieu Bott
Aure‐Eline Grillot
Sabine Chahory
Marion Phélip
Coline Jondeau
Matthieu Bott
Aure‐Eline Grillot
Sabine Chahory
collection Wiley Open Access
contents Accuracy and Reliability of Telediagnosis Approach for Canine and Feline Ophthalmological Emergencies: A Retrospective Study of 100 Cases Marion Phélip Coline Jondeau Matthieu Bott Aure‐Eline Grillot Sabine Chahory Veterinary Ophthalmology ABSTRACT Objectives To evaluate the sensitivity of ocular pain detection by email, as well as the concordance between telediagnosis by email and the diagnosis established in consultation for canine or feline ophthalmological emergencies. Animals Studied 65 dogs and 35 cats. Procedures Retrospective study of 100 ophthalmological emergencies with a contact by email before being examined by a specialized ophthalmology department. Telediagnoses from one European College of Veterinary Ophthalmologists (ECVO) diplomate and three ECVO residents retrospectively derived from the email communications were compared to clinical diagnoses following consultations. Analysis was focused on signs of ocular pain and ocular disease diagnosis. Results Sensitivity of detecting ocular pain by email was 79%. This sensitivity significantly improved in emails with photographs attached (89%; p  < 0.01). Inter‐operator reproducibility of remote email diagnosis was satisfactory when diagnosis was possible ( K  = 0.82). Concordance between remote email diagnosis and diagnosis made in consultation was satisfactory for the four clinicians for all ocular conditions ( K  = 0.85 ± 0.08), but unsatisfactory when restricted to corneal conditions ( K  = 0.66 ± 0.16). There was also a significant positive association between excellent photograph quality and diagnostic concordance ( p  = 0.01). Conclusions This exploratory study represents the first description of the use of veterinary teleophthalmology for email triage and telediagnosis of canine and feline ophthalmological emergencies. In our study, emails were a reliable tool for detecting ocular pain and giving a diagnostic orientation, especially when photographs were attached. 10.1111/vop.70121 http://onlinelibrary.wiley.com/termsAndConditions#vor
doi_str_mv 10.1111/vop.70121
format Artículo Open Access
id wiley_oa_10_1111_vop_70121
institution Wiley Open Access
license_str_mv http://onlinelibrary.wiley.com/termsAndConditions#vor
publishDate 2025
publisher Wiley
record_format wiley_oa
spellingShingle Accuracy and Reliability of Telediagnosis Approach for Canine and Feline Ophthalmological Emergencies: A Retrospective Study of 100 Cases
Marion Phélip
Coline Jondeau
Matthieu Bott
Aure‐Eline Grillot
Sabine Chahory
Veterinary Ophthalmology
Accuracy and Reliability of Telediagnosis Approach for Canine and Feline Ophthalmological Emergencies: A Retrospective Study of 100 Cases Marion Phélip Coline Jondeau Matthieu Bott Aure‐Eline Grillot Sabine Chahory Veterinary Ophthalmology ABSTRACT Objectives To evaluate the sensitivity of ocular pain detection by email, as well as the concordance between telediagnosis by email and the diagnosis established in consultation for canine or feline ophthalmological emergencies. Animals Studied 65 dogs and 35 cats. Procedures Retrospective study of 100 ophthalmological emergencies with a contact by email before being examined by a specialized ophthalmology department. Telediagnoses from one European College of Veterinary Ophthalmologists (ECVO) diplomate and three ECVO residents retrospectively derived from the email communications were compared to clinical diagnoses following consultations. Analysis was focused on signs of ocular pain and ocular disease diagnosis. Results Sensitivity of detecting ocular pain by email was 79%. This sensitivity significantly improved in emails with photographs attached (89%; p  < 0.01). Inter‐operator reproducibility of remote email diagnosis was satisfactory when diagnosis was possible ( K  = 0.82). Concordance between remote email diagnosis and diagnosis made in consultation was satisfactory for the four clinicians for all ocular conditions ( K  = 0.85 ± 0.08), but unsatisfactory when restricted to corneal conditions ( K  = 0.66 ± 0.16). There was also a significant positive association between excellent photograph quality and diagnostic concordance ( p  = 0.01). Conclusions This exploratory study represents the first description of the use of veterinary teleophthalmology for email triage and telediagnosis of canine and feline ophthalmological emergencies. In our study, emails were a reliable tool for detecting ocular pain and giving a diagnostic orientation, especially when photographs were attached. 10.1111/vop.70121 http://onlinelibrary.wiley.com/termsAndConditions#vor
title Accuracy and Reliability of Telediagnosis Approach for Canine and Feline Ophthalmological Emergencies: A Retrospective Study of 100 Cases
topic Veterinary Ophthalmology
url https://onlinelibrary.wiley.com/doi/10.1111/vop.70121