Breath‐by‐breath measurement of alveolar gas exchange must preserve mass balance and conform to a physiological definition of a breath

Fuente: Wiley Open Access
Saved in:
Bibliographic Details
Main Authors: Michele Girardi, Carlo Capelli, Carrie Ferguson, Susan A. Ward, Harry B. Rossiter
Format: Artículo Open Access
Published: Wiley 2025
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1867006549688320000
author Michele Girardi
Carlo Capelli
Carrie Ferguson
Susan A. Ward
Harry B. Rossiter
author_facet Michele Girardi
Carlo Capelli
Carrie Ferguson
Susan A. Ward
Harry B. Rossiter
Michele Girardi
Carlo Capelli
Carrie Ferguson
Susan A. Ward
Harry B. Rossiter
collection Wiley Open Access
contents Breath‐by‐breath measurement of alveolar gas exchange must preserve mass balance and conform to a physiological definition of a breath Michele Girardi Carlo Capelli Carrie Ferguson Susan A. Ward Harry B. Rossiter Experimental Physiology AbstractTidal breathing in awake humans is variable. This variability causes changes in lung gas stores that affect gas exchange measurements. To overcome this, several algorithms provide solutions for breath‐by‐breath alveolar gas exchange measurement; however, there is no consensus on a physiologically robust method suitable for widespread application. A recent approach, the ‘independent‐breath’ (IND) algorithm, avoids the complexity of measuring breath‐by‐breath changes in lung volume by redefining what is meant by a ‘breath’. Specifically, it defines a single breathing cycle as the time between equal values of the / (or /) ratio, that is, the ratio of fractional concentrations of lung‐expired O2 (or CO2) and nitrogen (N2). These developments imply that the end of one breath is not, by necessity, aligned with the start of the next. Here we demonstrate how the use of the IND algorithm fails to conserve breath‐by‐breath mass balance of O2 and CO2 exchanged between the atmosphere and tissues (and vice versa). We propose a new term, within the IND algorithm, designed to overcome this limitation. We also present the far‐reaching implications of using algorithms based on alternative definitions of the breathing cycle, including challenges in measuring and interpreting the respiratory exchange ratio, pulmonary gas exchange efficiency, dead space fraction of the breath, control of breathing, and a broad spectrum of clinically relevant cardiopulmonary exercise testing variables. Therefore, we do not support the widespread adoption of currently available alternative definitions of the breathing cycle as a legitimate solution for breath‐by‐breath alveolar gas exchange measurement in research or clinical settings. 10.1113/ep092221 http://creativecommons.org/licenses/by/4.0/
doi_str_mv 10.1113/ep092221
format Artículo Open Access
id wiley_oa_10_1113_ep092221
institution Wiley Open Access
license_str_mv http://creativecommons.org/licenses/by/4.0/
publishDate 2025
publisher Wiley
record_format wiley_oa
spellingShingle Breath‐by‐breath measurement of alveolar gas exchange must preserve mass balance and conform to a physiological definition of a breath
Michele Girardi
Carlo Capelli
Carrie Ferguson
Susan A. Ward
Harry B. Rossiter
Experimental Physiology
Breath‐by‐breath measurement of alveolar gas exchange must preserve mass balance and conform to a physiological definition of a breath Michele Girardi Carlo Capelli Carrie Ferguson Susan A. Ward Harry B. Rossiter Experimental Physiology AbstractTidal breathing in awake humans is variable. This variability causes changes in lung gas stores that affect gas exchange measurements. To overcome this, several algorithms provide solutions for breath‐by‐breath alveolar gas exchange measurement; however, there is no consensus on a physiologically robust method suitable for widespread application. A recent approach, the ‘independent‐breath’ (IND) algorithm, avoids the complexity of measuring breath‐by‐breath changes in lung volume by redefining what is meant by a ‘breath’. Specifically, it defines a single breathing cycle as the time between equal values of the / (or /) ratio, that is, the ratio of fractional concentrations of lung‐expired O2 (or CO2) and nitrogen (N2). These developments imply that the end of one breath is not, by necessity, aligned with the start of the next. Here we demonstrate how the use of the IND algorithm fails to conserve breath‐by‐breath mass balance of O2 and CO2 exchanged between the atmosphere and tissues (and vice versa). We propose a new term, within the IND algorithm, designed to overcome this limitation. We also present the far‐reaching implications of using algorithms based on alternative definitions of the breathing cycle, including challenges in measuring and interpreting the respiratory exchange ratio, pulmonary gas exchange efficiency, dead space fraction of the breath, control of breathing, and a broad spectrum of clinically relevant cardiopulmonary exercise testing variables. Therefore, we do not support the widespread adoption of currently available alternative definitions of the breathing cycle as a legitimate solution for breath‐by‐breath alveolar gas exchange measurement in research or clinical settings. 10.1113/ep092221 http://creativecommons.org/licenses/by/4.0/
title Breath‐by‐breath measurement of alveolar gas exchange must preserve mass balance and conform to a physiological definition of a breath
topic Experimental Physiology
url https://physoc.onlinelibrary.wiley.com/doi/10.1113/EP092221