NEX4EX – A novel exercise device enabling resistive, plyometric and sensorimotor training during deep‐space missions: A case report

Fuente: Wiley Open Access
Guardado en:
Detalles Bibliográficos
Autores principales: Jonas Böcker, Jochen Zange, Markus Gruber, Guillaume Fau, Rainer Rawer, Sören Törholm, Arnaud Runge, Jörn Rittweger
Formato: Artículo Open Access
Publicado: Wiley 2025
Materias:
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1867006297720750080
author Jonas Böcker
Jochen Zange
Markus Gruber
Guillaume Fau
Rainer Rawer
Sören Törholm
Arnaud Runge
Jörn Rittweger
author_facet Jonas Böcker
Jochen Zange
Markus Gruber
Guillaume Fau
Rainer Rawer
Sören Törholm
Arnaud Runge
Jörn Rittweger
Jonas Böcker
Jochen Zange
Markus Gruber
Guillaume Fau
Rainer Rawer
Sören Törholm
Arnaud Runge
Jörn Rittweger
collection Wiley Open Access
contents NEX4EX – A novel exercise device enabling resistive, plyometric and sensorimotor training during deep‐space missions: A case report Jonas Böcker Jochen Zange Markus Gruber Guillaume Fau Rainer Rawer Sören Törholm Arnaud Runge Jörn Rittweger Experimental Physiology AbstractDuring weightlessness, the human neuro–muscular–skeletal system undergoes maladaptation to the microgravity environment. The European Space Agency (ESA) project NEX4EX, ‘Novel Exercise Hardware for Exploration’, developed an advanced multipurpose exerciser offering resistive (RES), plyometric (PLYO) and sensorimotor (SENSO) exercises. It is the aim of this case report to assess the functionality of the device. NEX4EX offers RES in terms of squats and heel raises, and PYLO in terms of countermovement jumps and hops. RES and PLYO were compared with standard exercises on ground as reference. SENSO were generated by creating disturbances of the body posture by means of random, rapid pulling on a shoulder harness in four directions and by an oscillating platform. For SENSO, the results showed clear postural reflexes in trunk and leg muscles to stabilise upright posture after perturbation stimuli at the shoulders. RES and PLYO were carried out accurately on NEX4EX by the participants, but with reduced loads compared to reference (up to −37% for RES; up to −24% for PLYO). This resulted in reduced muscle activation for RES, whereas the muscle activation stayed comparable for PLYO. A reduced maximum take‐off velocity during PLYO (up to −66%) was shown leading to a reduced jump height (up to −72%). Although some exercises could not be performed with the same intensity with NEX4EX, in general it enabled all intended exercises. The basic functionality of the device was shown, and thus the device showed its potential as an integrative countermeasure device for upcoming deep‐space missions. 10.1113/ep092721 http://creativecommons.org/licenses/by/4.0/
doi_str_mv 10.1113/ep092721
format Artículo Open Access
id wiley_oa_10_1113_ep092721
institution Wiley Open Access
license_str_mv http://creativecommons.org/licenses/by/4.0/
publishDate 2025
publisher Wiley
record_format wiley_oa
spellingShingle NEX4EX – A novel exercise device enabling resistive, plyometric and sensorimotor training during deep‐space missions: A case report
Jonas Böcker
Jochen Zange
Markus Gruber
Guillaume Fau
Rainer Rawer
Sören Törholm
Arnaud Runge
Jörn Rittweger
Experimental Physiology
NEX4EX – A novel exercise device enabling resistive, plyometric and sensorimotor training during deep‐space missions: A case report Jonas Böcker Jochen Zange Markus Gruber Guillaume Fau Rainer Rawer Sören Törholm Arnaud Runge Jörn Rittweger Experimental Physiology AbstractDuring weightlessness, the human neuro–muscular–skeletal system undergoes maladaptation to the microgravity environment. The European Space Agency (ESA) project NEX4EX, ‘Novel Exercise Hardware for Exploration’, developed an advanced multipurpose exerciser offering resistive (RES), plyometric (PLYO) and sensorimotor (SENSO) exercises. It is the aim of this case report to assess the functionality of the device. NEX4EX offers RES in terms of squats and heel raises, and PYLO in terms of countermovement jumps and hops. RES and PLYO were compared with standard exercises on ground as reference. SENSO were generated by creating disturbances of the body posture by means of random, rapid pulling on a shoulder harness in four directions and by an oscillating platform. For SENSO, the results showed clear postural reflexes in trunk and leg muscles to stabilise upright posture after perturbation stimuli at the shoulders. RES and PLYO were carried out accurately on NEX4EX by the participants, but with reduced loads compared to reference (up to −37% for RES; up to −24% for PLYO). This resulted in reduced muscle activation for RES, whereas the muscle activation stayed comparable for PLYO. A reduced maximum take‐off velocity during PLYO (up to −66%) was shown leading to a reduced jump height (up to −72%). Although some exercises could not be performed with the same intensity with NEX4EX, in general it enabled all intended exercises. The basic functionality of the device was shown, and thus the device showed its potential as an integrative countermeasure device for upcoming deep‐space missions. 10.1113/ep092721 http://creativecommons.org/licenses/by/4.0/
title NEX4EX – A novel exercise device enabling resistive, plyometric and sensorimotor training during deep‐space missions: A case report
topic Experimental Physiology
url https://physoc.onlinelibrary.wiley.com/doi/10.1113/EP092721