On the autocorrelation of measurement results for gas volume and calorific value in fiscal metering in gas grids

Fuente: Zenodo
Saved in:
Bibliographic Details
Main Authors: Gugole, Federica, LI, Meng, van der Veen, Adriaan M.H.
Format: Recurso digital
Published: Zenodo 2025
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866901391541272576
author Gugole, Federica
LI, Meng
van der Veen, Adriaan M.H.
author_facet Gugole, Federica
LI, Meng
van der Veen, Adriaan M.H.
contents <p>The fiscal metering of natural gas is often performed using a flow meter and a gas chromatograph. The flow meter measures the volume flow rate of the gas and the gas chromatograph measures the composition, from which the calorific value is calculated. The energy is then calculated as the product of the volume and the calorific value. The uncertainty of the energy delivered (or received) is an important parameter for operating the gas grid. Currently, the energy values used to compute the total energy are considered mutually independent. However, the underlying processes affecting the gas flow through a pipe are continuous. We analysed the correlation between successive measurements due to temporal variations in the physical process by applying autoregressive moving average (ARMA) models to a set of measurement data taken at a metering station in the Dutch gas grid. The analysis showed that the volume time series can be modelled as an autoregressive model of order 1, while the time series of the calorific value can be described by an autoregressive model of order 2. These correlations lead to an increase of the instrumental measurement uncertainty associated to the total energy of about 50%.</p>
format Recurso digital
id zenodo_https___doi_org_10_1051_epjconf_202532309003
institution Zenodo
language
publishDate 2025
publisher Zenodo
record_format zenodo
spellingShingle On the autocorrelation of measurement results for gas volume and calorific value in fiscal metering in gas grids
Gugole, Federica
LI, Meng
van der Veen, Adriaan M.H.
natural gas
hydrogen
fiscal metering
autocorrelation
time series analysis
measurement uncertainty
custody transfer
<p>The fiscal metering of natural gas is often performed using a flow meter and a gas chromatograph. The flow meter measures the volume flow rate of the gas and the gas chromatograph measures the composition, from which the calorific value is calculated. The energy is then calculated as the product of the volume and the calorific value. The uncertainty of the energy delivered (or received) is an important parameter for operating the gas grid. Currently, the energy values used to compute the total energy are considered mutually independent. However, the underlying processes affecting the gas flow through a pipe are continuous. We analysed the correlation between successive measurements due to temporal variations in the physical process by applying autoregressive moving average (ARMA) models to a set of measurement data taken at a metering station in the Dutch gas grid. The analysis showed that the volume time series can be modelled as an autoregressive model of order 1, while the time series of the calorific value can be described by an autoregressive model of order 2. These correlations lead to an increase of the instrumental measurement uncertainty associated to the total energy of about 50%.</p>
title On the autocorrelation of measurement results for gas volume and calorific value in fiscal metering in gas grids
topic natural gas
hydrogen
fiscal metering
autocorrelation
time series analysis
measurement uncertainty
custody transfer
url https://doi.org/10.1051/epjconf/202532309003