RESEARCH OF CONCENTRATIONS OF POLLUTANTS IN THE VERTICAL PROFILE OF THE ATMOSPHERE OF THE ZENICA VALLEY USING UNMANNED ARIEAL VEHICLES

Fuente: Zenodo
Guardado en:
Detalles Bibliográficos
Autores principales: Nusret Imamovic , Halim Prcanovic , Mirnes Durakovic , Adnan Masic and Sanela Beganovic, Azrudin Husika
Formato: Recurso digital
Publicado: Zenodo 2025
Materias:
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1866901413622185984
author Nusret Imamovic , Halim Prcanovic , Mirnes Durakovic , Adnan Masic and Sanela Beganovic
Azrudin Husika
author_facet Nusret Imamovic , Halim Prcanovic , Mirnes Durakovic , Adnan Masic and Sanela Beganovic
Azrudin Husika
contents <p>This paper presents a study of air pollution in the vertical profile of the atmosphere during periods with and without temperature inversion in the Zenica valley. Unmanned aerial vehicles (drones) equipped with sensors for measuring the concentration of suspended particles, atmospheric pressure and air temperature were used for the study. The measurements were carried out at three different locations in the Zenica valley in two different periods. The study shows that pollutants remain below the inversion layer during the inversion period and that concentrations drop sharply at heights above the floor of the inversion layer. The measurements were carried out in December 2024 and January 2025 at three locations (Institut, Kamberovi apolje and Banlozi) along the Zenica valley, which, in addition to industrial sources of pollution, also contains a large number of small house stows distributed on the slopes of the hills surrounding the Zenica valley on three sides.</p> <p> </p>
format Recurso digital
id zenodo_https___doi_org_10_21474_IJAR01_21097
institution Zenodo
language
publishDate 2025
publisher Zenodo
record_format zenodo
spellingShingle RESEARCH OF CONCENTRATIONS OF POLLUTANTS IN THE VERTICAL PROFILE OF THE ATMOSPHERE OF THE ZENICA VALLEY USING UNMANNED ARIEAL VEHICLES
Nusret Imamovic , Halim Prcanovic , Mirnes Durakovic , Adnan Masic and Sanela Beganovic
Azrudin Husika
Vertical Profile of the Atmosphere Ground Temperature Inversion Pollutants Mixing Layer Height
<p>This paper presents a study of air pollution in the vertical profile of the atmosphere during periods with and without temperature inversion in the Zenica valley. Unmanned aerial vehicles (drones) equipped with sensors for measuring the concentration of suspended particles, atmospheric pressure and air temperature were used for the study. The measurements were carried out at three different locations in the Zenica valley in two different periods. The study shows that pollutants remain below the inversion layer during the inversion period and that concentrations drop sharply at heights above the floor of the inversion layer. The measurements were carried out in December 2024 and January 2025 at three locations (Institut, Kamberovi apolje and Banlozi) along the Zenica valley, which, in addition to industrial sources of pollution, also contains a large number of small house stows distributed on the slopes of the hills surrounding the Zenica valley on three sides.</p> <p> </p>
title RESEARCH OF CONCENTRATIONS OF POLLUTANTS IN THE VERTICAL PROFILE OF THE ATMOSPHERE OF THE ZENICA VALLEY USING UNMANNED ARIEAL VEHICLES
topic Vertical Profile of the Atmosphere Ground Temperature Inversion Pollutants Mixing Layer Height
url https://doi.org/10.21474/IJAR01/21097