To Evaluate Safety on Direct Trocar Insertion

Fuente: Zenodo
Salvato in:
Dettagli Bibliografici
Autori principali: Sonam Sharma, Ramesh Sonowal, Dhurjyoti Nandan Das
Natura: Recurso digital
Lingua:inglese
Pubblicazione: Zenodo 2024
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866902052488085504
author Sonam Sharma
Ramesh Sonowal
Dhurjyoti Nandan Das
author_facet Sonam Sharma
Ramesh Sonowal
Dhurjyoti Nandan Das
contents <p><strong>Introduction:</strong> Direct trocar insertion is a minimally invasive surgical technique used to insert instruments into the body through small incisions, to reducing recovery time and minimizing tissue damage. <strong>Aims and Objective:</strong> To develop and refine techniques for direct trocar insertion, enhancing precision and safety, to minimizing complications, and improving patient outcomes through innovative research and its clinical application. <strong>Method:</strong> A study was conducted with 45 patients undergoing laparoscopic surgery. A 10-mm trocar was directly inserted into the peritoneal cavity without prior pneumoperitoneum. Patients were positioned supine, and a small infraumbilical incision was made. The trocar was inserted at a 90-degree angle using controlled force. Entry was confirmed by visualizing the peritoneal cavity with a laparoscope. Patient outcomes, insertion time, and complications were recorded. No major complications occurred, and average insertion time was 30 seconds. <strong>Results:</strong> The study investigates the efficacy of direct trocar insertion (DTI) in laparoscopic surgeries. Results show that DTI reduces the risk of visceral and vascular injuries compared to the Veress needle technique. Patients undergoing DTI experienced shorter setup times and fewer postoperative complications. The findings suggest that DTI is a safer and more efficient method for establishing pneumoperitoneum, enhancing overall surgical outcomes. <strong>Conclusion: </strong>The study investigates the efficacy of direct trocar insertion (DTI) in laparoscopic surgeries. Results show that DTI reduces the risk of visceral and vascular injuries compared to the Veress needle technique. Patients undergoing DTI experienced shorter setup times and fewer postoperative complications. The findings suggest that DTI is a safer and more efficient method for establishing pneumoperitoneum, enhancing overall surgical outcomes.</p> <p> </p> <div> </div>
format Recurso digital
id zenodo_https___doi_org_10_5281_zenodo_14590883
institution Zenodo
language eng
publishDate 2024
publisher Zenodo
record_format zenodo
spellingShingle To Evaluate Safety on Direct Trocar Insertion
Sonam Sharma
Ramesh Sonowal
Dhurjyoti Nandan Das
Direct Trocar Insertion, Veress Needle, Laparoscopic Surgeries, Visceral And Vascular Injury
<p><strong>Introduction:</strong> Direct trocar insertion is a minimally invasive surgical technique used to insert instruments into the body through small incisions, to reducing recovery time and minimizing tissue damage. <strong>Aims and Objective:</strong> To develop and refine techniques for direct trocar insertion, enhancing precision and safety, to minimizing complications, and improving patient outcomes through innovative research and its clinical application. <strong>Method:</strong> A study was conducted with 45 patients undergoing laparoscopic surgery. A 10-mm trocar was directly inserted into the peritoneal cavity without prior pneumoperitoneum. Patients were positioned supine, and a small infraumbilical incision was made. The trocar was inserted at a 90-degree angle using controlled force. Entry was confirmed by visualizing the peritoneal cavity with a laparoscope. Patient outcomes, insertion time, and complications were recorded. No major complications occurred, and average insertion time was 30 seconds. <strong>Results:</strong> The study investigates the efficacy of direct trocar insertion (DTI) in laparoscopic surgeries. Results show that DTI reduces the risk of visceral and vascular injuries compared to the Veress needle technique. Patients undergoing DTI experienced shorter setup times and fewer postoperative complications. The findings suggest that DTI is a safer and more efficient method for establishing pneumoperitoneum, enhancing overall surgical outcomes. <strong>Conclusion: </strong>The study investigates the efficacy of direct trocar insertion (DTI) in laparoscopic surgeries. Results show that DTI reduces the risk of visceral and vascular injuries compared to the Veress needle technique. Patients undergoing DTI experienced shorter setup times and fewer postoperative complications. The findings suggest that DTI is a safer and more efficient method for establishing pneumoperitoneum, enhancing overall surgical outcomes.</p> <p> </p> <div> </div>
title To Evaluate Safety on Direct Trocar Insertion
topic Direct Trocar Insertion, Veress Needle, Laparoscopic Surgeries, Visceral And Vascular Injury
url https://doi.org/10.5281/zenodo.14590883