Commissioning of CT Simulator-Acceptance Testing and Quality Assurance

Fuente: Zenodo
Enregistré dans:
Détails bibliographiques
Auteur principal: Priya Jacob
Format: Recurso digital
Publié: Zenodo 2023
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1866901550521122816
author Priya Jacob
author_facet Priya Jacob
contents <p>This study evaluated the clinical use of a newly installed computed tomography (CT) simulator (GE Hangwei Medical Systems Co. Ltd, China) in the Department of Radiation Oncology (Figure 3). Licensing was granted by the Atomic Energy Regulatory Board (AERB), Government of India3. A pencil ionization chamber connected to a suitable electrometer, along with a head/body phantom, was used to measure doses in the axial and peripheral cavities of the phantom for typical techniques.<br>Image quality parameters such as the Hounsfield unit (HU) value of water, noise level, homogeneity, presence of artifacts, spatial resolution, contrast, and slice thickness were assessed using a CT performance phantom. All test items were evaluated to ensure they met the required tolerance levels. CT calibration curves, representing the relationship between CT number and relative electron density, were obtained for dose calculations in the treatment planning system. The positional accuracy of the lasers was also verified. The volume CT dose indices (CTDIvol) were 15.74 mGy for the head phantom and 8.11 mGy for the body phantom. The HU accuracy, noise level, and homogeneity for the CT simulator were -2 HU, 10% of the specified value, and 1 HU, respectively. A high contrast resolution test phantom was used to assess spatial resolution, with the smallest resolvable bar/hole pattern being 0.6 mm (8.3333 lp/cm). The CT simulator demonstrated comparable performance and was deemed acceptable for clinical use.</p>
format Recurso digital
id zenodo_https___doi_org_10_5281_zenodo_14945265
institution Zenodo
language
publishDate 2023
publisher Zenodo
record_format zenodo
spellingShingle Commissioning of CT Simulator-Acceptance Testing and Quality Assurance
Priya Jacob
<p>This study evaluated the clinical use of a newly installed computed tomography (CT) simulator (GE Hangwei Medical Systems Co. Ltd, China) in the Department of Radiation Oncology (Figure 3). Licensing was granted by the Atomic Energy Regulatory Board (AERB), Government of India3. A pencil ionization chamber connected to a suitable electrometer, along with a head/body phantom, was used to measure doses in the axial and peripheral cavities of the phantom for typical techniques.<br>Image quality parameters such as the Hounsfield unit (HU) value of water, noise level, homogeneity, presence of artifacts, spatial resolution, contrast, and slice thickness were assessed using a CT performance phantom. All test items were evaluated to ensure they met the required tolerance levels. CT calibration curves, representing the relationship between CT number and relative electron density, were obtained for dose calculations in the treatment planning system. The positional accuracy of the lasers was also verified. The volume CT dose indices (CTDIvol) were 15.74 mGy for the head phantom and 8.11 mGy for the body phantom. The HU accuracy, noise level, and homogeneity for the CT simulator were -2 HU, 10% of the specified value, and 1 HU, respectively. A high contrast resolution test phantom was used to assess spatial resolution, with the smallest resolvable bar/hole pattern being 0.6 mm (8.3333 lp/cm). The CT simulator demonstrated comparable performance and was deemed acceptable for clinical use.</p>
title Commissioning of CT Simulator-Acceptance Testing and Quality Assurance
url https://doi.org/10.5281/zenodo.14945265