ANALYZING THE EFFECTS OF FIRE ON THE STABILITY OF ECCENTRICALLY BRACED HIGH-RISE STEEL STRUCTURES

Fuente: Zenodo
Gespeichert in:
Bibliographische Detailangaben
1. Verfasser: Al-Taie, Ahmed Kareem
Format: Recurso digital
Sprache:Englisch
Veröffentlicht: Zenodo 2025
Schlagworte:
Online-Zugang:
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
_version_ 1866902197678112768
author Al-Taie, Ahmed Kareem
author_facet Al-Taie, Ahmed Kareem
contents <p><span>In this research, the evaluation of progressive damage due to fire in high-rise steel structures with diverging braces has been done. For this purpose, a frame with two openings and one floor has been selected from the reference article, and the fire scenario was implemented in one of the openings, and the horizontal displacement of the middle of the structure and the top of the column with the displacement values obtained from the reference article, comparison and accuracy. Was measured in the continuation of the research, 24 samples were analyzed in 3 categories. There are 15 floors in the first category of samples, 20 floors in the second category of samples, and 25 floors in the third category of samples. In each category, the first 4 samples are without braces and the second 4 samples are with divergent braces. In each category, the fire scenario was in the middle column of the first floor in the first sample, in the side column of the first floor in the second sample, in the middle column of the middle floor in the third sample, and in the side column of the middle floor in the fourth sample. The samples were subjected to static load and fire in the desired column, and the following results were obtained from this research. </span></p>
format Recurso digital
id zenodo_https___doi_org_10_5281_zenodo_15496067
institution Zenodo
language eng
publishDate 2025
publisher Zenodo
record_format zenodo
spellingShingle ANALYZING THE EFFECTS OF FIRE ON THE STABILITY OF ECCENTRICALLY BRACED HIGH-RISE STEEL STRUCTURES
Al-Taie, Ahmed Kareem
High-rise structures, Divergent braces, Lateral loads, Progressive failure, Fire resistance in structures
<p><span>In this research, the evaluation of progressive damage due to fire in high-rise steel structures with diverging braces has been done. For this purpose, a frame with two openings and one floor has been selected from the reference article, and the fire scenario was implemented in one of the openings, and the horizontal displacement of the middle of the structure and the top of the column with the displacement values obtained from the reference article, comparison and accuracy. Was measured in the continuation of the research, 24 samples were analyzed in 3 categories. There are 15 floors in the first category of samples, 20 floors in the second category of samples, and 25 floors in the third category of samples. In each category, the first 4 samples are without braces and the second 4 samples are with divergent braces. In each category, the fire scenario was in the middle column of the first floor in the first sample, in the side column of the first floor in the second sample, in the middle column of the middle floor in the third sample, and in the side column of the middle floor in the fourth sample. The samples were subjected to static load and fire in the desired column, and the following results were obtained from this research. </span></p>
title ANALYZING THE EFFECTS OF FIRE ON THE STABILITY OF ECCENTRICALLY BRACED HIGH-RISE STEEL STRUCTURES
topic High-rise structures, Divergent braces, Lateral loads, Progressive failure, Fire resistance in structures
url https://doi.org/10.5281/zenodo.15496067