SOHO EPHIN Calibration
Fuente:
Zenodo
Salvato in:
| Autore principale: | |
|---|---|
| Natura: | Recurso digital |
| Pubblicazione: |
Zenodo
2025
|
| Accesso online: | |
| Tags: |
Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
|
| _version_ | 1866902036666122240 |
|---|---|
| author | Institute of Experimental and Applied Physics at University of Kiel |
| author_facet | Institute of Experimental and Applied Physics at University of Kiel |
| contents | <p>Each document contains values measured at the rigidity given in the file name at the Hahn-Meitner-Institute in 1995.<br>The header is as follows:</p> <p>ID, IND, Penetration Depth, Coincidence, Segment in Detector A, Segment in Detector B, ADC Value in Detector A, Gain Level in Detector A, ADC Value in Detector B, Gain Level in Detector A, ADC Value in Detector C, Gain Level in Detector A, ADC Value in Detector D, Gain Level in Detector A, ADC Value in Detector E, Gain Level in Detector A</p> <p>The gain levels in each detector are multiplicative factors to convert the ADC value to MeV values as follows:</p> <p>Det A: 0: 3/1023<br> 1: 30/1023<br> <br>Det B: 0: 3/1023<br> 1: 45/1023<br> <br>Det C: 0: 16.07/1023<br> 1: 166.7/1023<br> <br>Det D: 0: 20/1023<br> 1: 225/1023<br> <br>Det E: 0: 20/1023<br> 1: 225/1023</p> |
| format | Recurso digital |
| id | zenodo_https___doi_org_10_5281_zenodo_15853403 |
| institution | Zenodo |
| language | |
| publishDate | 2025 |
| publisher | Zenodo |
| record_format | zenodo |
| spellingShingle | SOHO EPHIN Calibration Institute of Experimental and Applied Physics at University of Kiel <p>Each document contains values measured at the rigidity given in the file name at the Hahn-Meitner-Institute in 1995.<br>The header is as follows:</p> <p>ID, IND, Penetration Depth, Coincidence, Segment in Detector A, Segment in Detector B, ADC Value in Detector A, Gain Level in Detector A, ADC Value in Detector B, Gain Level in Detector A, ADC Value in Detector C, Gain Level in Detector A, ADC Value in Detector D, Gain Level in Detector A, ADC Value in Detector E, Gain Level in Detector A</p> <p>The gain levels in each detector are multiplicative factors to convert the ADC value to MeV values as follows:</p> <p>Det A: 0: 3/1023<br> 1: 30/1023<br> <br>Det B: 0: 3/1023<br> 1: 45/1023<br> <br>Det C: 0: 16.07/1023<br> 1: 166.7/1023<br> <br>Det D: 0: 20/1023<br> 1: 225/1023<br> <br>Det E: 0: 20/1023<br> 1: 225/1023</p> |
| title | SOHO EPHIN Calibration |
| url | https://doi.org/10.5281/zenodo.15853403 |