Bio-Quantum Fusion Sensor: A Cry4-Graphene Magneto-Chemistry Patch for Real-Time Edge Diagnostics in Tokamak Plasmas

Fuente: Zenodo
Guardado en:
Detalles Bibliográficos
Autor principal: margolin, ido
Formato: Recurso digital
Publicado: Zenodo 2025
Materias:
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1866902177987952640
author margolin, ido
author_facet margolin, ido
contents <p>Runaway-electron events in magnetic-confinement fusion are triggered by nT edge-field jitter coinciding with radical-burst surface chemistry. Conventional Hall probes or IR cameras cannot co-resolve magnetic perturbations and reactive-oxygen species (ROS) at sub-millisecond scales. We present the Bio-Quantum Fusion Sensor (BQFS)—a multilayer Cry4-graphene patch only 80 nm thick that detects ΔB≥5 nT and ROS concentration change ≥50 ppm at 10 kHz. The readout leverages Faraday-rotation magneto-optics in Bi:YIG waveguides and graphene Dirac-point conductance shifts induced by Cry4 radical-pair spin states. Thermal and neutron survivability are enhanced via a Bi₂Te₃ thermoelectric vapor-arc cooler and self-healing Dirac-Klein coating. A coupled reinforcement-learning (RL) controller consumes BQFS streams to cut unplanned quenches by 30% in simulation. We outline a 2027-28 linear-plasma pilot and provide open CAD, firmware and analysis notebooks.</p>
format Recurso digital
id zenodo_https___doi_org_10_5281_zenodo_16737690
institution Zenodo
language
publishDate 2025
publisher Zenodo
record_format zenodo
spellingShingle Bio-Quantum Fusion Sensor: A Cry4-Graphene Magneto-Chemistry Patch for Real-Time Edge Diagnostics in Tokamak Plasmas
margolin, ido
Fusion Energy
Tokamak
Plasma Diagnostics
Quantum Sensing
Cryptochrome (Cry4)
Graphene
Biosensor
Runaway Electrons
<p>Runaway-electron events in magnetic-confinement fusion are triggered by nT edge-field jitter coinciding with radical-burst surface chemistry. Conventional Hall probes or IR cameras cannot co-resolve magnetic perturbations and reactive-oxygen species (ROS) at sub-millisecond scales. We present the Bio-Quantum Fusion Sensor (BQFS)—a multilayer Cry4-graphene patch only 80 nm thick that detects ΔB≥5 nT and ROS concentration change ≥50 ppm at 10 kHz. The readout leverages Faraday-rotation magneto-optics in Bi:YIG waveguides and graphene Dirac-point conductance shifts induced by Cry4 radical-pair spin states. Thermal and neutron survivability are enhanced via a Bi₂Te₃ thermoelectric vapor-arc cooler and self-healing Dirac-Klein coating. A coupled reinforcement-learning (RL) controller consumes BQFS streams to cut unplanned quenches by 30% in simulation. We outline a 2027-28 linear-plasma pilot and provide open CAD, firmware and analysis notebooks.</p>
title Bio-Quantum Fusion Sensor: A Cry4-Graphene Magneto-Chemistry Patch for Real-Time Edge Diagnostics in Tokamak Plasmas
topic Fusion Energy
Tokamak
Plasma Diagnostics
Quantum Sensing
Cryptochrome (Cry4)
Graphene
Biosensor
Runaway Electrons
url https://doi.org/10.5281/zenodo.16737690