ARTIFICIAL NEURAL NETWORK APPLICATION FOR CASCADING FAILURE MITIGATION IN RENEWABLE POWER GENERATION PLANTS

Fuente: Zenodo
Enregistré dans:
Détails bibliographiques
Auteurs principaux: S.N EMECHETA, C.B MBACHU, I OKONKWO
Format: Recurso digital
Langue:anglais
Publié: Zenodo 2025
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1866901470968807424
author S.N EMECHETA
C.B MBACHU
I OKONKWO
author_facet S.N EMECHETA
C.B MBACHU
I OKONKWO
contents <p><strong><span lang="EN-US">Abstract:</span></strong><span lang="EN-US"> The lack of adequate fault detection and mitigation strategy has resulted to constant fault cascade on the power generation plants which has led to power plant shutdown and black outs, causing bottlenecks to the economic development of nations. The paper centered on the utilization of artificial intelligent models for the detection and mitigation of machine and inverter faults in the hydro and photovoltaic power plant that was operational in Kaiji power plant and Kaduna Solar power plant, Northern Nigeria. The artificial intelligent models utilized were artificial neural network (ANN) and Fuzzy Logic. The mathematical model for the generation plant was generated and represented in SIMULINK with current signal, voltage signal and speed being the parameters utilized for the measurement of the conditions in the gas plant. From the results presented, it was seen that the current signal, voltage signal and speed, For the fault occurrence in Hydro power plant, Fuzzy logic had 5.998mins, ANN mitigated fault time is 13.4992mins.<span>  </span>For the fault occurrence in solar PV system, Fuzzy logic had 5.9988mins mitigation time, ANN mitigated fault for 13.2697 mins. The ANN model had better fault mitigation time.</span></p> <p><strong><span lang="EN-US">Keywords:</span></strong><span lang="EN-US"> Hydro plant, Solar plant (PV), faults, ANN, Fuzzy, Detection, Mitigation.</span></p> <p><strong><span lang="EN-US">Title:</span></strong><span lang="EN-US"> ARTIFICIAL NEURAL NETWORK APPLICATION FOR CASCADING FAILURE MITIGATION IN RENEWABLE POWER GENERATION PLANTS</span></p> <p><strong><span lang="EN-US">Author:</span></strong><span lang="EN-US"> S.N EMECHETA, C.B MBACHU, I OKONKWO</span></p> <p><strong><span lang="EN-US">International Journal of Novel Research in Electrical and Mechanical Engineering</span></strong></p> <p><strong><span lang="EN-US">ISSN 2394-9678</span></strong></p> <p><strong><span lang="EN-US">Vol. 12, Issue 1, September 2024 - August 2025</span></strong></p> <p><strong><span lang="EN-US">Page No: 65-78</span></strong></p> <p><strong><span lang="EN-US">Novelty Journals</span></strong></p> <p><strong><span lang="EN-US">Website: www.noveltyjournals.com</span></strong></p> <p><strong><span lang="EN-US">Published Date: 11-August-2025</span></strong></p> <p><strong><span lang="EN-US">DOI: <a href="https://doi.org/10.5281/zenodo.16793697">https://doi.org/10.5281/zenodo.16793697</a></span></strong></p> <p><strong><span lang="EN-US">Paper Download Link (Source)</span></strong></p> <p><strong><span lang="EN-US"><a href="https://www.noveltyjournals.com/upload/paper/ARTIFICIAL%20NEURAL%20NETWORK%20APPLICATION-11082025-6.pdf">https://www.noveltyjournals.com/upload/paper/ARTIFICIAL%20NEURAL%20NETWORK%20APPLICATION-11082025-6.pdf</a></span></strong></p>
format Recurso digital
id zenodo_https___doi_org_10_5281_zenodo_16793697
institution Zenodo
language eng
publishDate 2025
publisher Zenodo
record_format zenodo
spellingShingle ARTIFICIAL NEURAL NETWORK APPLICATION FOR CASCADING FAILURE MITIGATION IN RENEWABLE POWER GENERATION PLANTS
S.N EMECHETA
C.B MBACHU
I OKONKWO
Hydro plant
Solar plant (PV)
faults
ANN
Fuzzy
Detection
Mitigation
<p><strong><span lang="EN-US">Abstract:</span></strong><span lang="EN-US"> The lack of adequate fault detection and mitigation strategy has resulted to constant fault cascade on the power generation plants which has led to power plant shutdown and black outs, causing bottlenecks to the economic development of nations. The paper centered on the utilization of artificial intelligent models for the detection and mitigation of machine and inverter faults in the hydro and photovoltaic power plant that was operational in Kaiji power plant and Kaduna Solar power plant, Northern Nigeria. The artificial intelligent models utilized were artificial neural network (ANN) and Fuzzy Logic. The mathematical model for the generation plant was generated and represented in SIMULINK with current signal, voltage signal and speed being the parameters utilized for the measurement of the conditions in the gas plant. From the results presented, it was seen that the current signal, voltage signal and speed, For the fault occurrence in Hydro power plant, Fuzzy logic had 5.998mins, ANN mitigated fault time is 13.4992mins.<span>  </span>For the fault occurrence in solar PV system, Fuzzy logic had 5.9988mins mitigation time, ANN mitigated fault for 13.2697 mins. The ANN model had better fault mitigation time.</span></p> <p><strong><span lang="EN-US">Keywords:</span></strong><span lang="EN-US"> Hydro plant, Solar plant (PV), faults, ANN, Fuzzy, Detection, Mitigation.</span></p> <p><strong><span lang="EN-US">Title:</span></strong><span lang="EN-US"> ARTIFICIAL NEURAL NETWORK APPLICATION FOR CASCADING FAILURE MITIGATION IN RENEWABLE POWER GENERATION PLANTS</span></p> <p><strong><span lang="EN-US">Author:</span></strong><span lang="EN-US"> S.N EMECHETA, C.B MBACHU, I OKONKWO</span></p> <p><strong><span lang="EN-US">International Journal of Novel Research in Electrical and Mechanical Engineering</span></strong></p> <p><strong><span lang="EN-US">ISSN 2394-9678</span></strong></p> <p><strong><span lang="EN-US">Vol. 12, Issue 1, September 2024 - August 2025</span></strong></p> <p><strong><span lang="EN-US">Page No: 65-78</span></strong></p> <p><strong><span lang="EN-US">Novelty Journals</span></strong></p> <p><strong><span lang="EN-US">Website: www.noveltyjournals.com</span></strong></p> <p><strong><span lang="EN-US">Published Date: 11-August-2025</span></strong></p> <p><strong><span lang="EN-US">DOI: <a href="https://doi.org/10.5281/zenodo.16793697">https://doi.org/10.5281/zenodo.16793697</a></span></strong></p> <p><strong><span lang="EN-US">Paper Download Link (Source)</span></strong></p> <p><strong><span lang="EN-US"><a href="https://www.noveltyjournals.com/upload/paper/ARTIFICIAL%20NEURAL%20NETWORK%20APPLICATION-11082025-6.pdf">https://www.noveltyjournals.com/upload/paper/ARTIFICIAL%20NEURAL%20NETWORK%20APPLICATION-11082025-6.pdf</a></span></strong></p>
title ARTIFICIAL NEURAL NETWORK APPLICATION FOR CASCADING FAILURE MITIGATION IN RENEWABLE POWER GENERATION PLANTS
topic Hydro plant
Solar plant (PV)
faults
ANN
Fuzzy
Detection
Mitigation
url https://doi.org/10.5281/zenodo.16793697