CHROMATOGRAPHIC PROFILING OF CAFFEINE AND BENZOIC ACID IN CHOCOLATE PRODUCTS

Fuente: Zenodo
Guardado en:
Detalles Bibliográficos
Autores principales: Pradnya, Kulkarni Meera, Anant, Deshpande Suresh
Formato: Recurso digital
Lenguaje:inglés
Publicado: Zenodo 2025
Materias:
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1866901692160671744
author Pradnya, Kulkarni Meera
Anant, Deshpande Suresh
author_facet Pradnya, Kulkarni Meera
Anant, Deshpande Suresh
contents <p><em><span>A simple, sensitive, and precise high-performance liquid chromatography (HPLC) method was developed and validated for the simultaneous determination of caffeine and benzoic acid in food products. Separation was achieved using an Agilent Eclipse XDB C18 column (4.6 cm × 100 mm, i.d., 3.5 µm) with a mobile phase of phosphate buffer and methanol (70:30, v/v, pH 3.0) at a flow rate of 1.0 mL/min, and detection at 220 nm. The retention times were 2.5 min for caffeine and 8.4 min for benzoic acid. The method was validated for linearity, achieving a correlation coefficient of 0.9998, and demonstrated specificity, accuracy, precision, and rapidity. These results indicate that the proposed HPLC method is reliable and efficient, making it suitable for the quantitative analysis of caffeine and benzoic acid in aerated drinks, chocolates, and other food products</span></em></p>
format Recurso digital
id zenodo_https___doi_org_10_5281_zenodo_17521159
institution Zenodo
language eng
publishDate 2025
publisher Zenodo
record_format zenodo
spellingShingle CHROMATOGRAPHIC PROFILING OF CAFFEINE AND BENZOIC ACID IN CHOCOLATE PRODUCTS
Pradnya, Kulkarni Meera
Anant, Deshpande Suresh
Caffeine, Benzoic acid, High-performance liquid chromatography, C18 column, Method validation
<p><em><span>A simple, sensitive, and precise high-performance liquid chromatography (HPLC) method was developed and validated for the simultaneous determination of caffeine and benzoic acid in food products. Separation was achieved using an Agilent Eclipse XDB C18 column (4.6 cm × 100 mm, i.d., 3.5 µm) with a mobile phase of phosphate buffer and methanol (70:30, v/v, pH 3.0) at a flow rate of 1.0 mL/min, and detection at 220 nm. The retention times were 2.5 min for caffeine and 8.4 min for benzoic acid. The method was validated for linearity, achieving a correlation coefficient of 0.9998, and demonstrated specificity, accuracy, precision, and rapidity. These results indicate that the proposed HPLC method is reliable and efficient, making it suitable for the quantitative analysis of caffeine and benzoic acid in aerated drinks, chocolates, and other food products</span></em></p>
title CHROMATOGRAPHIC PROFILING OF CAFFEINE AND BENZOIC ACID IN CHOCOLATE PRODUCTS
topic Caffeine, Benzoic acid, High-performance liquid chromatography, C18 column, Method validation
url https://doi.org/10.5281/zenodo.17521159