Hand size and grip strengths of cardiovascular surgeons: Implications for cardiovascular device design

Fuente: Zenodo
Enregistré dans:
Détails bibliographiques
Auteur principal: Tyrrell, Grainne
Format: Recurso digital
Publié: Zenodo 2026
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1866901715772506112
author Tyrrell, Grainne
author_facet Tyrrell, Grainne
contents <p><em><span lang="EN-GB">Background:</span></em><span lang="EN-GB"> Cardiovascular surgeons interact with a variety of unique and complex catheter-based devices during procedures. Biomedical device design requires the application of anthropometric data from suitably representative user databases. However, there is a lack of anthropometric data and hand grip strengths of medical specialists generally, and notably for women surgeons.</span></p> <p><em><span lang="EN-GB">Study design:</span></em><span lang="EN-GB"> Stature, upper limb lengths, hand size measurements and hand grip strengths of interventional cardiologists and vascular surgeons were measured in line with ISO 7250. Anthropometers were used to gather stature and upper limb lengths, 3D scanning was used to record hand size, and hand grip strength was gathered using a handheld dynamometer and a pinch gauge. A repeated mixed measures ANOVA was performed to evaluate the effect of gender, grip type and hand dominance on grip strengths. </span></p> <p><em><span lang="EN-GB">Results: </span></em><span lang="EN-GB">Data from N = 49 (n = 27 women) cardiovascular surgeons are reported. Anthropometric data align with other surgical cohorts, where comparable data are available.</span> <span>Gender, grip type and hand dominance all had individual effects on hand grip strength at <em>p</em> < 0.05. </span></p> <p><em><span lang="EN-GB">Conclusions: </span></em><span lang="EN-GB">Cardio</span><span>vascular surgeons exhibited lower grip strengths than AAMI HE75 population means across power, key, and tripod grips, risking device designs that require excessive operating force. </span><span lang="EN-GB">These results highlight the need for device designs that accommodate end user anthropometry and grip strength rather than relying solely on normative databases. </span><span>Device handles should accommodate hand lengths of 175 - 195 mm and hand breadths over 96 mm, while grip forces should remain within limits of power grip 41N, precision pinch 7N, key pinch 11N, and tripod pinch 10N.</span></p>
format Recurso digital
id zenodo_https___doi_org_10_5281_zenodo_18596153
institution Zenodo
language
publishDate 2026
publisher Zenodo
record_format zenodo
spellingShingle Hand size and grip strengths of cardiovascular surgeons: Implications for cardiovascular device design
Tyrrell, Grainne
Hand anthropometry
Hand grip strength
endovascular surgery
cardiovascular surgeons
medical device design
<p><em><span lang="EN-GB">Background:</span></em><span lang="EN-GB"> Cardiovascular surgeons interact with a variety of unique and complex catheter-based devices during procedures. Biomedical device design requires the application of anthropometric data from suitably representative user databases. However, there is a lack of anthropometric data and hand grip strengths of medical specialists generally, and notably for women surgeons.</span></p> <p><em><span lang="EN-GB">Study design:</span></em><span lang="EN-GB"> Stature, upper limb lengths, hand size measurements and hand grip strengths of interventional cardiologists and vascular surgeons were measured in line with ISO 7250. Anthropometers were used to gather stature and upper limb lengths, 3D scanning was used to record hand size, and hand grip strength was gathered using a handheld dynamometer and a pinch gauge. A repeated mixed measures ANOVA was performed to evaluate the effect of gender, grip type and hand dominance on grip strengths. </span></p> <p><em><span lang="EN-GB">Results: </span></em><span lang="EN-GB">Data from N = 49 (n = 27 women) cardiovascular surgeons are reported. Anthropometric data align with other surgical cohorts, where comparable data are available.</span> <span>Gender, grip type and hand dominance all had individual effects on hand grip strength at <em>p</em> < 0.05. </span></p> <p><em><span lang="EN-GB">Conclusions: </span></em><span lang="EN-GB">Cardio</span><span>vascular surgeons exhibited lower grip strengths than AAMI HE75 population means across power, key, and tripod grips, risking device designs that require excessive operating force. </span><span lang="EN-GB">These results highlight the need for device designs that accommodate end user anthropometry and grip strength rather than relying solely on normative databases. </span><span>Device handles should accommodate hand lengths of 175 - 195 mm and hand breadths over 96 mm, while grip forces should remain within limits of power grip 41N, precision pinch 7N, key pinch 11N, and tripod pinch 10N.</span></p>
title Hand size and grip strengths of cardiovascular surgeons: Implications for cardiovascular device design
topic Hand anthropometry
Hand grip strength
endovascular surgery
cardiovascular surgeons
medical device design
url https://doi.org/10.5281/zenodo.18596153