Evaluation of low power diode laser and desensitizer agent as treatment of dentinal hypersensitivity: A clinical study

Fuente: Zenodo
Salvato in:
Dettagli Bibliografici
Autori principali: Dr. Sreenidhi Devathi, Dr. Srikanth Adusumilli, Dr. Suman Jalwadi, Dr. Mohan krishna Bondili, Dr. J. V. Subbamma
Natura: Recurso digital
Lingua:inglese
Pubblicazione: Zenodo 2026
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866901201628430336
author Dr. Sreenidhi Devathi
Dr. Srikanth Adusumilli
Dr. Suman Jalwadi
Dr. Mohan krishna Bondili
Dr. J. V. Subbamma
author_facet Dr. Sreenidhi Devathi
Dr. Srikanth Adusumilli
Dr. Suman Jalwadi
Dr. Mohan krishna Bondili
Dr. J. V. Subbamma
contents <p><strong><span>Abstract:<br></span></strong><strong><span>Abstract:</span></strong><span> Dentin hypersensitivity is a widespread and common</span><span> </span><span>ailment that is both painful and difficult to treat. Dentin exposure can occur as a result of attrition, abrasion, erosion, abfraction, hypoplastic enamel, gingival recession, defective restorations, improperly formed cemento-enamel junction (CEJ), caries, tooth cracking, trauma, iatrogenic reasons, faulty tooth brushing. A total of thirty patients with age group of above 30 years complaining of hypersensitivity were selected. </span></p> <p><strong><span>Materials and methods:</span></strong><span> The research participants were divided into three groups: Group A: Teeth treated with low power diode laser irradiation. Group B: Teeth treated with Ormocer based varnish. Group C: Teeth treated with low power diode laser irradiation + Ormocer based varnish. Patients were evaluated by using different stimuli. Cotton rolls were used to isolate the specific teeth and subjected to tactile, air blast tests. Visual analog scale was used to record scores at baseline, 7<sup>th</sup>, 14<sup>th</sup> and 30<sup>th</sup> day.</span></p> <p><span><strong>Results:</strong> </span><span lang="EN-GB">In Group A, the mean pain scores reduced from 9.3 to 3.2 from day 1 to 30, which was noted that the differences between all possible time point pairs were statistically significant in Group A. In Group B, the mean pain scores reduced from 8.6 to 4.00 from day 1 to 30, which was noted that the differences between all possible time point pairs were statistically significant in Group B. In Group C,<strong> </strong>the mean pain scores reduced from 9.00 to 1.00 from day 1 to 30, which was noted that the differences between all possible time point pairs were statistically significant in Group C. </span><span>The inter-group comparison of change in VAS scores from baseline to different time points. While there was no significant difference between the groups in the mean VAS change from baseline to Day 7, significant differences in mean VAS change from baseline to Day 14 and 30 were noted between the groups. From baseline to Day 30, Group C had the highest mean reduction in VAS score from baseline, followed by Group A and Group B. The differences between all possible pairs were statistically significant. </span></p> <p><strong><span>Conclusion:</span></strong><span> </span><span>The results of the current research suggest that all three treatment modalities were effective in reducing d entinal hypersensitivity over time. However, photobiomodulation therapy in combination with ormocer based varnish application demonstrated the most substantial and statistically significant reduction in VAS scores, particularly evident at Day 14 and Day 30.</span></p>
format Recurso digital
id zenodo_https___doi_org_10_5281_zenodo_18606377
institution Zenodo
language eng
publishDate 2026
publisher Zenodo
record_format zenodo
spellingShingle Evaluation of low power diode laser and desensitizer agent as treatment of dentinal hypersensitivity: A clinical study
Dr. Sreenidhi Devathi
Dr. Srikanth Adusumilli
Dr. Suman Jalwadi
Dr. Mohan krishna Bondili
Dr. J. V. Subbamma
<p><strong><span>Abstract:<br></span></strong><strong><span>Abstract:</span></strong><span> Dentin hypersensitivity is a widespread and common</span><span> </span><span>ailment that is both painful and difficult to treat. Dentin exposure can occur as a result of attrition, abrasion, erosion, abfraction, hypoplastic enamel, gingival recession, defective restorations, improperly formed cemento-enamel junction (CEJ), caries, tooth cracking, trauma, iatrogenic reasons, faulty tooth brushing. A total of thirty patients with age group of above 30 years complaining of hypersensitivity were selected. </span></p> <p><strong><span>Materials and methods:</span></strong><span> The research participants were divided into three groups: Group A: Teeth treated with low power diode laser irradiation. Group B: Teeth treated with Ormocer based varnish. Group C: Teeth treated with low power diode laser irradiation + Ormocer based varnish. Patients were evaluated by using different stimuli. Cotton rolls were used to isolate the specific teeth and subjected to tactile, air blast tests. Visual analog scale was used to record scores at baseline, 7<sup>th</sup>, 14<sup>th</sup> and 30<sup>th</sup> day.</span></p> <p><span><strong>Results:</strong> </span><span lang="EN-GB">In Group A, the mean pain scores reduced from 9.3 to 3.2 from day 1 to 30, which was noted that the differences between all possible time point pairs were statistically significant in Group A. In Group B, the mean pain scores reduced from 8.6 to 4.00 from day 1 to 30, which was noted that the differences between all possible time point pairs were statistically significant in Group B. In Group C,<strong> </strong>the mean pain scores reduced from 9.00 to 1.00 from day 1 to 30, which was noted that the differences between all possible time point pairs were statistically significant in Group C. </span><span>The inter-group comparison of change in VAS scores from baseline to different time points. While there was no significant difference between the groups in the mean VAS change from baseline to Day 7, significant differences in mean VAS change from baseline to Day 14 and 30 were noted between the groups. From baseline to Day 30, Group C had the highest mean reduction in VAS score from baseline, followed by Group A and Group B. The differences between all possible pairs were statistically significant. </span></p> <p><strong><span>Conclusion:</span></strong><span> </span><span>The results of the current research suggest that all three treatment modalities were effective in reducing d entinal hypersensitivity over time. However, photobiomodulation therapy in combination with ormocer based varnish application demonstrated the most substantial and statistically significant reduction in VAS scores, particularly evident at Day 14 and Day 30.</span></p>
title Evaluation of low power diode laser and desensitizer agent as treatment of dentinal hypersensitivity: A clinical study
url https://doi.org/10.5281/zenodo.18606377