_version_ 1866901481405284352
author de Veigy, Luc
author_facet de Veigy, Luc
contents <blockquote><strong>Status: pilot protocol proposal, no patients included (February 2026).</strong></blockquote> <blockquote>This document presents a prospective in vivo pilot protocol to test the immediate effects of standardized glenohumeral recentering (RGH) in a constrained curved-space framework. The protocol combines: (1) a clinically driven, descending reading of shoulder stiffness (structure, anterior capsule, posterior capsule, recentering, micro-instability; S/Cant/Cpost/R/M) in a standardized supine position with elevated head; (2) dynamic monitoring with inertial measurement units (IMU) on thorax, scapula and humerus, plus a scapular support pressure sensor; and (3) geometric proxy descriptors derived from a synthetic glenoid surface (GEOMEDICS v0.2.2, toy model), used to describe functional “contact areas” without any claim of anatomical measurement of the true center of rotation.</blockquote> <blockquote>The main objective is to determine whether standardized recentering produces rapid, objectifiable changes in amplitude (internal/external rotation around a clinically defined neutral C₀ and elevation), scapular compensation (composite index IC_scap) and proxy functional area on the synthetic glenoid surface. Secondary aims include feasibility, signal quality, intra-subject stability across three sessions, and approximate effect sizes for future sample size calculations.</blockquote> <blockquote>The protocol explicitly distinguishes fixed parameters from pilot-adjustable ones (with a freeze rule after the first five complete subjects) and proposes simple clinical output scores such as an “articular yield” (ΔAmplitude/ΔIC_scap) and a bilateral structural score K_struct with a normalization index (IN). This pre-registered framework is intended as an open, reproducible basis for future in vivo validation and ex vivo or imaging-based studies of shoulder biomechanics in constrained curved space.</blockquote> <blockquote> <blockquote><strong>Statut : protocole pilote proposé, aucun patient inclus à ce jour (février 2026).</strong></blockquote> <blockquote>Ce document décrit un protocole pilote prospectif visant à tester les effets immédiats d’un recentrage gléno-huméral standardisé (RGH) dans un cadre biomécanique en « espace courbe contraint ». Le protocole associe : (1) une lecture clinique descendante de la raideur de l’épaule (structure, capsule antérieure, capsule postérieure, recentrage, micro-instabilité ; S/Cant/Cpost/R/M) en décubitus dorsal tête surélevée ; (2) un suivi dynamique par capteurs inertiels (IMU) sur thorax, scapula et humérus, complétés par un capteur d’appui scapulaire ; (3) des descripteurs géométriques proxy issus d’une glène synthétique (GEOMEDICS v0.2.2, <em>toy model</em>), utilisés pour décrire des « aires fonctionnelles » sans prétendre mesurer le centre de rotation anatomique réel.</blockquote> <blockquote>L’objectif principal est de déterminer si un recentrage standardisé entraîne des modifications rapides et objectivables de l’amplitude (RI/RE autour d’un neutre clinique C₀, élévation), des compensations scapulaires (indice composite IC_scap) et de l’aire fonctionnelle proxy. Les objectifs secondaires portent sur la faisabilité, la qualité des signaux, la stabilité intra-sujet sur trois séances et l’estimation d’ordres de grandeur d’effet en vue d’un calcul ultérieur de puissance.</blockquote> <blockquote>Le protocole précise les paramètres figés et ceux ajustables en phase pilote (avec règle de gel après cinq sujets complets), et propose des scores de sortie simples : rendement articulaire (ΔAmplitude/ΔIC_scap), score structurel bilatéral K_struct et indice de normalisation (IN). Il constitue un cadre ouvert et reproductible pour de futures validations in vivo et des travaux ex vivo ou en imagerie dynamique sur la biomécanique de l’épaule en espace courbe contraint.</blockquote> </blockquote>
format Recurso digital
id zenodo_https___doi_org_10_5281_zenodo_18622870
institution Zenodo
language fra
publishDate 2026
publisher Zenodo
record_format zenodo
spellingShingle In vivo protocol for gleno-huméral recentering in constrained Curved Space: pilot proposal
de Veigy, Luc
shoulder biomechanics • glenohumeral joint • shoulder recentering • curved space kinematics • constrained glenoid surface • scapular compensation • inertial measurement units (IMU) • wearable sensors • pilot clinical protocol • functional shoulder area • scapulohumeral rhythm • toy model (GEOMEDICS) • biomécanique de l'épaule • articulation gléno-humérale • recentrage gléno-huméral • cinématique en espace courbe • surface glénoïdienne contrainte • compensation scapulaire • capteurs inertiels (IMU) • capteurs portés • protocole clinique pilote • aire fonctionnelle d'épaule • rythme scapulo-huméral • modèle jouet (GEOMEDICS)
<blockquote><strong>Status: pilot protocol proposal, no patients included (February 2026).</strong></blockquote> <blockquote>This document presents a prospective in vivo pilot protocol to test the immediate effects of standardized glenohumeral recentering (RGH) in a constrained curved-space framework. The protocol combines: (1) a clinically driven, descending reading of shoulder stiffness (structure, anterior capsule, posterior capsule, recentering, micro-instability; S/Cant/Cpost/R/M) in a standardized supine position with elevated head; (2) dynamic monitoring with inertial measurement units (IMU) on thorax, scapula and humerus, plus a scapular support pressure sensor; and (3) geometric proxy descriptors derived from a synthetic glenoid surface (GEOMEDICS v0.2.2, toy model), used to describe functional “contact areas” without any claim of anatomical measurement of the true center of rotation.</blockquote> <blockquote>The main objective is to determine whether standardized recentering produces rapid, objectifiable changes in amplitude (internal/external rotation around a clinically defined neutral C₀ and elevation), scapular compensation (composite index IC_scap) and proxy functional area on the synthetic glenoid surface. Secondary aims include feasibility, signal quality, intra-subject stability across three sessions, and approximate effect sizes for future sample size calculations.</blockquote> <blockquote>The protocol explicitly distinguishes fixed parameters from pilot-adjustable ones (with a freeze rule after the first five complete subjects) and proposes simple clinical output scores such as an “articular yield” (ΔAmplitude/ΔIC_scap) and a bilateral structural score K_struct with a normalization index (IN). This pre-registered framework is intended as an open, reproducible basis for future in vivo validation and ex vivo or imaging-based studies of shoulder biomechanics in constrained curved space.</blockquote> <blockquote> <blockquote><strong>Statut : protocole pilote proposé, aucun patient inclus à ce jour (février 2026).</strong></blockquote> <blockquote>Ce document décrit un protocole pilote prospectif visant à tester les effets immédiats d’un recentrage gléno-huméral standardisé (RGH) dans un cadre biomécanique en « espace courbe contraint ». Le protocole associe : (1) une lecture clinique descendante de la raideur de l’épaule (structure, capsule antérieure, capsule postérieure, recentrage, micro-instabilité ; S/Cant/Cpost/R/M) en décubitus dorsal tête surélevée ; (2) un suivi dynamique par capteurs inertiels (IMU) sur thorax, scapula et humérus, complétés par un capteur d’appui scapulaire ; (3) des descripteurs géométriques proxy issus d’une glène synthétique (GEOMEDICS v0.2.2, <em>toy model</em>), utilisés pour décrire des « aires fonctionnelles » sans prétendre mesurer le centre de rotation anatomique réel.</blockquote> <blockquote>L’objectif principal est de déterminer si un recentrage standardisé entraîne des modifications rapides et objectivables de l’amplitude (RI/RE autour d’un neutre clinique C₀, élévation), des compensations scapulaires (indice composite IC_scap) et de l’aire fonctionnelle proxy. Les objectifs secondaires portent sur la faisabilité, la qualité des signaux, la stabilité intra-sujet sur trois séances et l’estimation d’ordres de grandeur d’effet en vue d’un calcul ultérieur de puissance.</blockquote> <blockquote>Le protocole précise les paramètres figés et ceux ajustables en phase pilote (avec règle de gel après cinq sujets complets), et propose des scores de sortie simples : rendement articulaire (ΔAmplitude/ΔIC_scap), score structurel bilatéral K_struct et indice de normalisation (IN). Il constitue un cadre ouvert et reproductible pour de futures validations in vivo et des travaux ex vivo ou en imagerie dynamique sur la biomécanique de l’épaule en espace courbe contraint.</blockquote> </blockquote>
title In vivo protocol for gleno-huméral recentering in constrained Curved Space: pilot proposal
topic shoulder biomechanics • glenohumeral joint • shoulder recentering • curved space kinematics • constrained glenoid surface • scapular compensation • inertial measurement units (IMU) • wearable sensors • pilot clinical protocol • functional shoulder area • scapulohumeral rhythm • toy model (GEOMEDICS) • biomécanique de l'épaule • articulation gléno-humérale • recentrage gléno-huméral • cinématique en espace courbe • surface glénoïdienne contrainte • compensation scapulaire • capteurs inertiels (IMU) • capteurs portés • protocole clinique pilote • aire fonctionnelle d'épaule • rythme scapulo-huméral • modèle jouet (GEOMEDICS)
url https://doi.org/10.5281/zenodo.18622870