Non-Linear Analysis of RC Building Considering Soil Structure Interaction

Fuente: Zenodo
Guardado en:
Detalles Bibliográficos
Autores principales: Prashant Amaragol, Dr. Tejas . Doshi
Formato: Recurso digital
Publicado: Zenodo 2020
Materias:
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1866901687336173568
author Prashant Amaragol
Dr. Tejas . Doshi
author_facet Prashant Amaragol
Dr. Tejas . Doshi
contents Pushover analysis which is also stated as Non-linear static analysis is widely used procedures for the seismic assessment or evaluation of the structures. The pushover model is used to measure the new structure's seismic demand or for current structures. Within this research pushover review is carried out to consider G+10 multi-storeyed building in zones using SAP 2000 software From the results of the study it was discovered that the hinges are established between IO (Immediate Occupancy) and LS (Life Safety) suggesting that the building is secure. The structural model analysed in this state is therefore safe. Therefore, the structural model studied in this State is safe. The effect of interaction of the Soil Structure on the seismic efficiency of the construction is considered and the building is built with and without considering interaction of soil-structure (SSI).The RC building symmetric plan and These buildings are modelled, designed according to IS 456:2000 and evaluated using SAP2000 software under two separate boundary conditions, namely fixed-base, and considering nonlinear dynamic analysis soil-structure relationship.
format Recurso digital
id zenodo_https___doi_org_10_5281_zenodo_18955871
institution Zenodo
language
publishDate 2020
publisher Zenodo
record_format zenodo
spellingShingle Non-Linear Analysis of RC Building Considering Soil Structure Interaction
Prashant Amaragol
Dr. Tejas . Doshi
Seismic analysis
SAP 2000
Different plan configuration
pushover analysis
Soil structure interaction
Pushover analysis which is also stated as Non-linear static analysis is widely used procedures for the seismic assessment or evaluation of the structures. The pushover model is used to measure the new structure's seismic demand or for current structures. Within this research pushover review is carried out to consider G+10 multi-storeyed building in zones using SAP 2000 software From the results of the study it was discovered that the hinges are established between IO (Immediate Occupancy) and LS (Life Safety) suggesting that the building is secure. The structural model analysed in this state is therefore safe. Therefore, the structural model studied in this State is safe. The effect of interaction of the Soil Structure on the seismic efficiency of the construction is considered and the building is built with and without considering interaction of soil-structure (SSI).The RC building symmetric plan and These buildings are modelled, designed according to IS 456:2000 and evaluated using SAP2000 software under two separate boundary conditions, namely fixed-base, and considering nonlinear dynamic analysis soil-structure relationship.
title Non-Linear Analysis of RC Building Considering Soil Structure Interaction
topic Seismic analysis
SAP 2000
Different plan configuration
pushover analysis
Soil structure interaction
url https://doi.org/10.5281/zenodo.18955871