Co‑Located Liquid‑Cooled Data Centres and Offices: Waste‑Heat‑Driven Summer Cooling and Heat‑Pump‑Augmented Winter Heating

Fuente: Zenodo
Salvato in:
Dettagli Bibliografici
Autore principale: Solanki, Shyamal
Natura: Recurso digital
Pubblicazione: Zenodo 2026
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866901969595006976
author Solanki, Shyamal
author_facet Solanki, Shyamal
contents <p class="FirstParagraph"><span>Liquid‑cooled data centres can export mid‑grade waste heat (~50–75 °C), enabling coupled office energy systems that reduce purchased electricity for summer cooling and displace heating energy in winter. This paper develops an energy‑ and exergy‑based screening model to compare (A) adsorption/absorption sorption cooling, (B) ejector refrigeration, (C) heat-engine/ORC‑driven vapour compression, and (D) heat‑pump augmentation, applied to a 10,000 m² office (24 °C setpoint, 32 °C ambient; 9 h/day, 5 days/week; 70 W/m² average and 120 W/m² peak cooling intensity). Using a high‑performance baseline defined by TSE = 0.731 kW/RT from a published office worked example, Variant A (COP</span><span></span><span>=0.60) reduces occupied-hours cooling electricity by ~52% while requiring ~1.17 MW driving heat average (IT ~1.3–1.9 MW depending on </span><span></span><span>). Variant B and C demand substantially larger driving heat due to low COP</span><span></span><span><span> </span>or low heat‑to‑work efficiency, while Variant D is most compelling for winter heating (e.g., district heating lift to 70–75 °C with COP</span><span></span><span><span> </span>≈ 4.5–5.0). Field reports show sorption cooling can degrade sharply with recooling‑water temperature on hot days, motivating hybrid controls and recooling-first design.</span></p>
format Recurso digital
id zenodo_https___doi_org_10_5281_zenodo_19517945
institution Zenodo
language
publishDate 2026
publisher Zenodo
record_format zenodo
spellingShingle Co‑Located Liquid‑Cooled Data Centres and Offices: Waste‑Heat‑Driven Summer Cooling and Heat‑Pump‑Augmented Winter Heating
Solanki, Shyamal
Thermodynamic engineering
Thermodynamics
HVAC
Heat pump
Cooling
Mechanical engineering
<p class="FirstParagraph"><span>Liquid‑cooled data centres can export mid‑grade waste heat (~50–75 °C), enabling coupled office energy systems that reduce purchased electricity for summer cooling and displace heating energy in winter. This paper develops an energy‑ and exergy‑based screening model to compare (A) adsorption/absorption sorption cooling, (B) ejector refrigeration, (C) heat-engine/ORC‑driven vapour compression, and (D) heat‑pump augmentation, applied to a 10,000 m² office (24 °C setpoint, 32 °C ambient; 9 h/day, 5 days/week; 70 W/m² average and 120 W/m² peak cooling intensity). Using a high‑performance baseline defined by TSE = 0.731 kW/RT from a published office worked example, Variant A (COP</span><span></span><span>=0.60) reduces occupied-hours cooling electricity by ~52% while requiring ~1.17 MW driving heat average (IT ~1.3–1.9 MW depending on </span><span></span><span>). Variant B and C demand substantially larger driving heat due to low COP</span><span></span><span><span> </span>or low heat‑to‑work efficiency, while Variant D is most compelling for winter heating (e.g., district heating lift to 70–75 °C with COP</span><span></span><span><span> </span>≈ 4.5–5.0). Field reports show sorption cooling can degrade sharply with recooling‑water temperature on hot days, motivating hybrid controls and recooling-first design.</span></p>