RP HPLC Method Development and Validation for The Simultaneous Estimation of Lansoprazole and Domperidone in Bulk and Capsule Dosage Form

Fuente: Zenodo
Enregistré dans:
Détails bibliographiques
Auteur principal: Kiran Vyavhare*, Aijaz Sheikh, K. Biyani
Format: Recurso digital
Publié: Zenodo 2026
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1866901802206625792
author Kiran Vyavhare*, Aijaz Sheikh, K. Biyani
author_facet Kiran Vyavhare*, Aijaz Sheikh, K. Biyani
contents <p class="MsoNormal"><span>The present research focuses on the development and validation of a simple, precise, and robust reverse-phase high-performance liquid chromatography (RP-HPLC) method for the simultaneous estimation of lansoprazole and domperidone in bulk and capsule dosage forms. The method was designed in accordance with International Council for Harmonisation (ICH) guidelines to ensure reliability and reproducibility for routine pharmaceutical analysis. Chromatographic separation was achieved using a C18 column with an optimized mobile phase composition, flow rate, and detection wavelength, resulting in well-resolved peaks for both drugs without interference from excipients. System suitability parameters, including retention time, theoretical plates, and tailing factor, were evaluated and found within acceptable limits, confirming the adequacy of the chromatographic system. Linearity was established over the concentration ranges of 5–25 µg/mL for lansoprazole and 10–50 µg/mL for domperidone, with correlation coefficients (r²) greater than 0.999, indicating excellent linearity. Accuracy studies demonstrated recovery values between 98–102%, validating the reliability of the method. Precision, assessed through intra-day and inter-day studies, showed %RSD values less than 2%, confirming reproducibility. Sensitivity was established with low limits of detection (LOD) and quantification (LOQ), highlighting the method’s capability to detect and quantify trace levels of both drugs. Robustness studies, performed by deliberate variations in flow rate and mobile phase composition, revealed no significant changes in results, thereby confirming method stability. The validated RP-HPLC method was successfully applied to the analysis of capsule dosage forms, demonstrating its suitability for routine quality control and pharmaceutical formulation studies. The method’s simplicity, accuracy, precision, and robustness make it a valuable analytical tool for simultaneous drug estimation in both academic and industrial </span><span>laboratories. This study contributes to the advancement of analytical methodologies by providing a reliable approach for the quality assurance of lansoprazole and domperidone formulations, ensuring compliance with regulatory standards and supporting therapeutic efficacy</span></p>
format Recurso digital
id zenodo_https___doi_org_10_5281_zenodo_19588400
institution Zenodo
language
publishDate 2026
publisher Zenodo
record_format zenodo
spellingShingle RP HPLC Method Development and Validation for The Simultaneous Estimation of Lansoprazole and Domperidone in Bulk and Capsule Dosage Form
Kiran Vyavhare*, Aijaz Sheikh, K. Biyani
RP-HPLC method development; Lansoprazole; Domperidone; Simultaneous estimation; Method validation; ICH guidelines
<p class="MsoNormal"><span>The present research focuses on the development and validation of a simple, precise, and robust reverse-phase high-performance liquid chromatography (RP-HPLC) method for the simultaneous estimation of lansoprazole and domperidone in bulk and capsule dosage forms. The method was designed in accordance with International Council for Harmonisation (ICH) guidelines to ensure reliability and reproducibility for routine pharmaceutical analysis. Chromatographic separation was achieved using a C18 column with an optimized mobile phase composition, flow rate, and detection wavelength, resulting in well-resolved peaks for both drugs without interference from excipients. System suitability parameters, including retention time, theoretical plates, and tailing factor, were evaluated and found within acceptable limits, confirming the adequacy of the chromatographic system. Linearity was established over the concentration ranges of 5–25 µg/mL for lansoprazole and 10–50 µg/mL for domperidone, with correlation coefficients (r²) greater than 0.999, indicating excellent linearity. Accuracy studies demonstrated recovery values between 98–102%, validating the reliability of the method. Precision, assessed through intra-day and inter-day studies, showed %RSD values less than 2%, confirming reproducibility. Sensitivity was established with low limits of detection (LOD) and quantification (LOQ), highlighting the method’s capability to detect and quantify trace levels of both drugs. Robustness studies, performed by deliberate variations in flow rate and mobile phase composition, revealed no significant changes in results, thereby confirming method stability. The validated RP-HPLC method was successfully applied to the analysis of capsule dosage forms, demonstrating its suitability for routine quality control and pharmaceutical formulation studies. The method’s simplicity, accuracy, precision, and robustness make it a valuable analytical tool for simultaneous drug estimation in both academic and industrial </span><span>laboratories. This study contributes to the advancement of analytical methodologies by providing a reliable approach for the quality assurance of lansoprazole and domperidone formulations, ensuring compliance with regulatory standards and supporting therapeutic efficacy</span></p>
title RP HPLC Method Development and Validation for The Simultaneous Estimation of Lansoprazole and Domperidone in Bulk and Capsule Dosage Form
topic RP-HPLC method development; Lansoprazole; Domperidone; Simultaneous estimation; Method validation; ICH guidelines
url https://doi.org/10.5281/zenodo.19588400