Supplementary Figures: Mechanisms of Ventilation Failure during CO2 Absorbent Canister Replacement in Anesthesia (Japanese version)
Fuente:
Zenodo
Salvato in:
| Autore principale: | |
|---|---|
| Natura: | Recurso digital |
| Lingua: | inglese |
| Pubblicazione: |
Zenodo
2026
|
| Soggetti: | |
| Accesso online: | |
| Tags: |
Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
|
| _version_ | 1866901976187404288 |
|---|---|
| author | Kuruma, Yuki |
| author_facet | Kuruma, Yuki |
| contents | <p>This repository contains supplementary figures (in Japanese) accompanying an article submitted to "Rinsho Masui" (Journal of Clinical Anesthesia, Japan).</p> <p>These figures illustrate the mechanisms of ventilation failure caused by intraoperative replacement of CO2 absorbent canister, including gas flow during mechanical ventilation and manual ventilation, and anesthesia machine structure.</p> <p>These materials are intended for educational purpose.</p> <p>An English version of the figures is also available in a separate repository.</p> |
| format | Recurso digital |
| id | zenodo_https___doi_org_10_5281_zenodo_19778689 |
| institution | Zenodo |
| language | eng |
| publishDate | 2026 |
| publisher | Zenodo |
| record_format | zenodo |
| spellingShingle | Supplementary Figures: Mechanisms of Ventilation Failure during CO2 Absorbent Canister Replacement in Anesthesia (Japanese version) Kuruma, Yuki anesthesia machine, CO2 absorbent, soda lime, ventilation failure, mechanical ventilation, manual ventilation, fresh gas decoupling, piston ventilator, turbine ventilator, bellows ventilator, gas leak, patient safety, Medicine, Anesthesiology, Medical Education <p>This repository contains supplementary figures (in Japanese) accompanying an article submitted to "Rinsho Masui" (Journal of Clinical Anesthesia, Japan).</p> <p>These figures illustrate the mechanisms of ventilation failure caused by intraoperative replacement of CO2 absorbent canister, including gas flow during mechanical ventilation and manual ventilation, and anesthesia machine structure.</p> <p>These materials are intended for educational purpose.</p> <p>An English version of the figures is also available in a separate repository.</p> |
| title | Supplementary Figures: Mechanisms of Ventilation Failure during CO2 Absorbent Canister Replacement in Anesthesia (Japanese version) |
| topic | anesthesia machine, CO2 absorbent, soda lime, ventilation failure, mechanical ventilation, manual ventilation, fresh gas decoupling, piston ventilator, turbine ventilator, bellows ventilator, gas leak, patient safety, Medicine, Anesthesiology, Medical Education |
| url | https://doi.org/10.5281/zenodo.19778689 |