Saved in:
Bibliographic Details
Main Authors: Gutierrez Vela, Yael, Espinoza, Shirly, Rebarz, Mateusz, Vazquez-Miranda, Saul, Ramanathan, Shriram, PATEL, RANJAN KUMAR
Format: Recurso digital
Language:
Published: Zenodo 2026
Online Access:https://doi.org/10.5281/zenodo.20433965
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866902312858943488
author Gutierrez Vela, Yael
Espinoza, Shirly
Rebarz, Mateusz
Vazquez-Miranda, Saul
Ramanathan, Shriram
PATEL, RANJAN KUMAR
author_facet Gutierrez Vela, Yael
Espinoza, Shirly
Rebarz, Mateusz
Vazquez-Miranda, Saul
Ramanathan, Shriram
PATEL, RANJAN KUMAR
contents <h3>Data available</h3> <p>Transient pseudo dielectric function and ellipsometric parameters (\Psi and \Delta) measured with a time-resolved pump-probe ellipsometry on a 50 nm NdNiO3 film deposited on LaAlO3.</p> <p>The data of the transient pseudo dielectric function and ellipsometric parameters (\Psi and \Delta) are provided for different pump wavelengths:.</p> <ul> <li>\lambda_{pump} = 266 nm </li> <li>\lambda_{pump} = 400 nm</li> <li>\lambda_{pump} = 800 nm </li> </ul> <h3>Naming of the files</h3> <p>In the .zip file that can be downloaded here, there are several folders.</p> <p>Each are named as NdNiO3_LaAlO3_pump_XX_nm where XXX is either 266, 400 or 800.</p> <p>In each folder are four files.</p> <ul> <li>delta.txt - values of \Delta.</li> <li>psi.txt- values of \Psi.</li> <li>pseudoepsilon1.txt - values of the real part of the transient pseudo dielectric function.</li> <li>pseudoepsilon2.txt- values of \Psi.</li> <li>diffpseudoepsilon1.txt- values of the changes in the real part of the transient pseudo dielectric function.</li> <li>diffpseudoepsilon2.txt- values of the changes imaginary part of the transient pseudo dielectric function.</li> </ul> <h3>Structure of the files</h3> <p>Each file has the same structure:</p> <p>The first row: an array time delays in picosecond for which measurements have been performed.</p> <p>In the rest of rows, the first element of the array are the photon energy, while the rest of the elements are the values of the transient dielectric function or ellipsometric parameters (\Psi and \Delta) at each of the elements in the time delay array.</p> <p>Example:</p> <p>time delay       t1                         t2                           t3</p> <p>E1(eV)      Delta(E1, t1)        Delta(E1, t2)          Delta(E1, t3)</p> <p>E2(eV)      Delta(E2, t1)       Delta(E2, t2)         Delta(E2, t3)</p> <p>E3(eV)      Delta(E3, t1)       Delta(E3, t2)         Delta(E3, t3)</p> <p> </p>
format Recurso digital
id zenodo_https___doi_org_10_5281_zenodo_20433965
institution Zenodo
language
publishDate 2026
publisher Zenodo
record_format zenodo
spellingShingle Time-resolved pump-probe ellipsometry measurements of 50 nm NdNiO3 thin films
Gutierrez Vela, Yael
Espinoza, Shirly
Rebarz, Mateusz
Vazquez-Miranda, Saul
Ramanathan, Shriram
PATEL, RANJAN KUMAR
<h3>Data available</h3> <p>Transient pseudo dielectric function and ellipsometric parameters (\Psi and \Delta) measured with a time-resolved pump-probe ellipsometry on a 50 nm NdNiO3 film deposited on LaAlO3.</p> <p>The data of the transient pseudo dielectric function and ellipsometric parameters (\Psi and \Delta) are provided for different pump wavelengths:.</p> <ul> <li>\lambda_{pump} = 266 nm </li> <li>\lambda_{pump} = 400 nm</li> <li>\lambda_{pump} = 800 nm </li> </ul> <h3>Naming of the files</h3> <p>In the .zip file that can be downloaded here, there are several folders.</p> <p>Each are named as NdNiO3_LaAlO3_pump_XX_nm where XXX is either 266, 400 or 800.</p> <p>In each folder are four files.</p> <ul> <li>delta.txt - values of \Delta.</li> <li>psi.txt- values of \Psi.</li> <li>pseudoepsilon1.txt - values of the real part of the transient pseudo dielectric function.</li> <li>pseudoepsilon2.txt- values of \Psi.</li> <li>diffpseudoepsilon1.txt- values of the changes in the real part of the transient pseudo dielectric function.</li> <li>diffpseudoepsilon2.txt- values of the changes imaginary part of the transient pseudo dielectric function.</li> </ul> <h3>Structure of the files</h3> <p>Each file has the same structure:</p> <p>The first row: an array time delays in picosecond for which measurements have been performed.</p> <p>In the rest of rows, the first element of the array are the photon energy, while the rest of the elements are the values of the transient dielectric function or ellipsometric parameters (\Psi and \Delta) at each of the elements in the time delay array.</p> <p>Example:</p> <p>time delay       t1                         t2                           t3</p> <p>E1(eV)      Delta(E1, t1)        Delta(E1, t2)          Delta(E1, t3)</p> <p>E2(eV)      Delta(E2, t1)       Delta(E2, t2)         Delta(E2, t3)</p> <p>E3(eV)      Delta(E3, t1)       Delta(E3, t2)         Delta(E3, t3)</p> <p> </p>
title Time-resolved pump-probe ellipsometry measurements of 50 nm NdNiO3 thin films
url https://doi.org/10.5281/zenodo.20433965